PROPANE (LP) CONVERSION KIT - 

1NP0347 - All Models except 130,000 BTU input
1NP0501 - 130,000 BTU input only

This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation.

SIDE RETURN FILTER RACKS - 

1SR0200 - All Models
1SR0302 - All Models
1SF0101 - All Models

BOTTOM RETURN FILTER RACKS - 

1BR0514 or 1BR0614 - For 14-1/2” cabinets
1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
1BR0524 or 1BR0624 - For 24-1/2” cabinets

1BR05xx series are galvanized steel filter racks. 1BR06xx
are pre-painted steel filter racks to match the appearance of
the furnace cabinet.

COMBUSTIBLE FLOOR BASE KIT - 

For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations. These
kits are also required in any applications where the furnace in
installed in a downflow configuration without an evaporator
coil, where the combustible floor base kit provides access for
combustible airflow.
1CB0514 - For 14-1/2” cabinets
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets

1CB0524 - For 24-1/2” cabinets

EAC TRANSITION KITS - 

For installation of EAC accessories with these furnaces to
provide easy transition of return airflow through the EAC to
get the proper sealing and reduced airflow leakage.

1TK1001 - For all models using side return
1TK1014 - For 14-1/2” cabinets using bottom return
1TK1017 - For 17-1/2” cabinets using bottom return
1TK1021 - For 21” cabinets using bottom return
1TK1024 - For 24-1/2” cabinets using bottom return

MASONRY CHIMNEY KITS - 

1CK0603
1CK0604
For installations where these furnaces are vented using
existing or new lined masonry chimneys.

HIGH ALTITUDE PRESSURE SWITCHES - 

For installation where the altitude is less than 8,000 feet it is
not required that the pressure switch be changed. For alti-
tudes above 8,000 feet, see kits below.
1PS3301
1PS3302

ROOM THERMOSTATS 

- A wide selection of compatible

thermosets are available to provide optimum performance
and features for any installation.

1H/1C, manual change-over electronic non-programmable 
thermostat.

1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.

1H/1C, auto/manual changeover, electronic programmable.

* For the most current accessory information, refer to the
price book or consult factory.

Summary of Contents for TG8S

Page 1: ... in upflow horizontal left or right or downflow installation with minimal conversion necessary Compact easy to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for reliable operation Low unit amp requirement fo...

Page 2: ... 8 L S100B12MP11 1200 B 17 1 2 16 3 8 11 8 108 TG 8 L S100C16MP11 1600 C 21 19 7 8 13 6 118 TG 8 L S100C20MP11 2000 C 21 19 7 8 13 6 122 TG 8 L S120C16MP11 1600 C 21 19 7 8 15 8 123 TG 8 L S120C20MP11 2000 C 21 19 7 8 15 8 129 TG 8 L S130D20MP11 2000 D 24 1 2 23 3 8 17 5 135 Ratings Physical Electrical Data Models Input Output AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Max Over Curr...

Page 3: ...quire the use of high velocity filters 2 Do not exceed 1800 CFM using a single side return and a 16x25 filter For CFM greater than 1800 you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter Recommended Filter Sizes CFM Cabinet Size Side in Bottom in 800 A 16 x 25 14 x 25 1000 A 16 x 25 14 x 25 1200 A 16 x 25 14 x 25 1200 B 16 x 25 16...

Page 4: ...4 For 14 1 2 cabinets 1CB0517 For 17 1 2 cabinets 1CB0521 For 21 cabinets 1CB0524 For 24 1 2 cabinets EAC TRANSITION KITS For installation of EAC accessories with these furnaces to provide easy transition of return airflow through the EAC to get the proper sealing and reduced airflow leakage 1TK1001 For all models using side return 1TK1014 For 14 1 2 cabinets using bottom return 1TK1017 For 17 1 2...

Page 5: ...2540 2448 2339 2224 2111 1974 1831 Medium High 2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 Medium Low 1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 Low 1396 1375 1348 1325 1263 1200 1150 1120 1052 965 TG 8 L S100B12MP11 High 1314 1318 1292 1265 1223 1177 1119 1051 971 890 Medium High 1010 1004 1003 995 992 956 914 857 798 721 Medium Low 812 805 796 786 777 754 727 685 626 560 Low 661 659...

Page 6: ...5 1192 1035 Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851 Low 1126 1115 1095 1049 1027 996 957 929 840 742 TG 8 L S080C22MP11 High 2972 2863 2769 2671 2571 2465 2352 2227 2095 1950 Medium High 2173 2146 2103 2082 2036 1966 1904 1827 1738 1621 Medium Low 1670 1667 1647 1618 1585 1549 1492 1408 1350 1238 Low 1371 1339 1317 1284 1259 1199 1147 1085 1024 928 TG 8 L S100B12MP11 High 1258 1278 ...

Reviews: