2. Installation Tips
Follow the steps below to Install the unit.
a The opening size required for installing the unit is to be down as follows: Unit dimension (D X W): 455
x 670 mm, opening size AA: 458 ~ 460 mm and BB: 673 ~ 675 mm and if Unit dimension (D X W) is
510 x 708 mm, opening size AA: 513 ~ 515 mm and BB: 711 ~ 713 mm with reference to Fig. - B.
b The Plastic Front Panel is the last Item that will be assembled to the unit during Installation, so
remove and keep it in a safe place to protect it from damages, Scratches and dirt.
c Unit installation should be such that, the outside rear of the Air conditioner Is between 5mm to 10mm
lower than the front of the Unit. This allows condensed water to drain off outside the Room.
Otherwise Condensed water and Rain may flow Into the Room. (See Fig. - H)
d Unscrew the two shipping screws from the lower rear portion of the Cabinet (See Fig. - F)
and slide out the Unit from the Cabinet.
e Fix the Long Urethane Foam (supplied with the Unit) on the 3 outer sides of the Cabinet as shown in
Fig. - G (Left, Top & Right) to weather seal any gap between the Cabinet and the Wooden Frame.
If your window opening size is larger than the one required, use Wooden blocks to reduce the gap
between the Unit and Wooden Frame.
OVER
200 mm
BEVELLED SIDES
CLEARANCE AT THE SIDES WHEN
WALL THICKNESS EXCEEDS 200 mm.
Fig. - E
CLEARANCE AT THE REAR SIDE
Fig. - C
WINDOW OPENING
DIMENSION FOR MOUNTING
Fig. - B
CLEARANCE AT THE SIDES
Fig. - D
200mm
50cm
AA
BB
200mm
200mm
90 cm
Min.
50
cm