036-21020-003 Rev. C (0203)
4
Unitary Products Group
- = Not applicable
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING
MODEL
ELECTRIC
2
HEAT KW
2. Single phase units require single phase 2HK heaters.
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
3. TXV = Use 1TV700 Series Kit.
EER
TOTAL SENS.
1 PH 12 SEER AC / N1AH + G2FD
H4DH018S06
N1AHB0806
2,5,8,10
17
G2FD024(S,H)17
650
18.6
14.0
12.50
-
10.80
N1AHB0806
2,5,8,10
17
G2FD030(S,H)17
650
19.0
14.3
12.50
-
10.80
H4DH024S06
N1AHB0806
2,5,8,10
17
G2FD024(S,H)17
850
23.4
17.6
12.10
-
10.90
N1AHB0806
2,5,8,10
17
G2FD030(S,H)17
850
23.4
17.6
12.00
-
10.90
H4DH030S06
N1AHB1206
5,8,10,15,19
17
G2FD030(S,H)17
1030
29.4
22.1
-
12.40
10.50
N1AHB1206
5,8,10,15,19
17
G2FD036(S,H)17
1030
30.0
22.5
12.40
-
10.60
H4DH036S06
N1AHB1206
5,8,10,15,19
17
G2FD036(S,H)17
1200
35.8
26.5
12.15
-
11.20
N1AHB1206
5,8,10,15,19
17
G2FD046(S,H)17
1200
36.2
26.8
12.30
-
11.20
N1AHD1406
5,8,10,15,19
24
G2FD048(S,H)24
1200
38.0
28.1
13.50
-
12.05
N1AHD1406
5,8,10,15,19
24
G2FD060(S,H)24
1200
38.5
28.5
13.70
-
12.20
H4DH042S06
N1AHC1606
5,8,10,15,20
21
G2FD042(S,H)21
1400
40.5
30.4
12.00
-
10.60
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1400
42.0
31.5
12.35
-
10.90
H4DH048S06
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1600
48.5
36.4
12.35
-
11.15
N1AHD2006
8,10,15,20,25,30
24
G2FD060(S,H)24
1600
50.0
37.5
12.50
13.00
11.45
H4DH060S06
N1AHD2006
8,10,15,20,25,30
24
G2FD060(S,H)24
1800
58.5
43.9
12.00
12.50
11.05
N1AHD2006
8,10,15,20,25,30
24
G2FD061H24
2000
60.0
45.0
12.50
12.50
11.25
1 PH 12 SEER AC / N1VS - VARIABLE SPEED
H4DH018S06
N1VSB12
10,15,18
17
G2FD024(S,H)17
650
20.0
15.0
-
13.50
11.20
H4DH024S06
N1VSB12
10,15,18
17
G2FD024(S,H)17
850
24.4
18.3
13.50
-
12.10
N1VSB12
10,15,18
17
G2FD036(S,H)17
860
24.6
18.5
13.55
-
12.10
H4DH030S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1030
31.0
23.3
13.40
-
11.30
N1VSB12
10,15,18
17
G2FD046(S,H)17
1000
32.6
22.8
13.50
-
11.50
H4DH036S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1200
35.6
26.7
13.10
-
12.05
N1VSC16
10,15,18
21
G2FD048(S,H)21
1200
38.0
28.5
14.10
-
12.55
H4DH042S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1380
42.5
31.9
13.35
-
11.70
H4DH048S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1590
49.0
36.8
13.00
-
11.70
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1600
50.5
37.9
13.10
-
11.90
H4DH060S06
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1780
59.0
44.3
12.40
-
11.40
N1VSD20
10,15,18,30
24
G2FD061H24
1780
60.5
45.4
-
13.00
11.80
1 PH 12 SEER AC / F2RP / RC / FP / FC / FV
4,5
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
H4DH018S06
F2RC/FC024
5,8,10
18
-
650
18.6
14.0
12.20
-
10.90
F2RP/FP018
2,5,8
18
-
650
18.0
13.5
12.00
-
10.70
F2RP/FP024
5,8,10
18
-
650
18.6
14.0
12.50
-
11.00
H4DH024S06
F2RC/FC024
5,8,10
18
-
850
23.0
17.3
12.00
-
10.80
F2RC/FC030
5,8,10,15
18
-
850
23.4
17.6
12.00
-
10.90
F2RP/FP024
5,8,10
18
-
850
24.0
18.0
12.10
-
10.90
F2RP/FP030
5,8,10,15
18
-
850
24.4
18.3
12.00
-
10.80
F2FP040
5,8,10,15
21
-
850
24.8
18.6
-
12.70
11.30
H4DH030S06
F2RC/FC030
5,8,10,15
18
-
1030
28.4
21.3
12.00
-
10.50
F2RP/FP030
5,8,10,15
18
-
1030
30.0
22.5
12.30
12.50
10.50
F2RP/FP036
5,8,10,15,19
21
-
1030
31.0
23.3
12.50
-
10.60
F2FP048
5,8,10,15,20,25
24
-
1030
31.4
23.6
12.60
-
10.70
H4DH036S06
F2RC/FC036
5,8,10,15
21
-
1200
35.6
26.7
12.35
-
11.10
F2RP/FP036
5,8,10,15,19
21
-
1200
36.2
27.2
12.50
-
11.45
F2RP/FP042
5,8,10,15
21
-
1200
36.4
27.3
12.50
-
11.50
F2FP045
5,8,10,15
24
-
1200
38.0
28.5
-
13.50
12.20
F2FP048
5,8,10,15,20,25
24
-
1200
36.8
27.6
12.80
-
11.80
H4DH042S06
F2RP/FP042
5,8,10,15
21
-
1400
40.5
30.4
12.00
-
10.50
F2FP045
5,8,10,15
24
-
1400
42.5
31.9
13.00
-
11.20
F2FP048
5,8,10,15,20,25
24
-
1400
41.5
31.1
12.20
-
10.65
H4DH048S06
F2FP048
5,8,10,15,20,25
24
-
1600
48.0
36.0
12.00
-
11.00
F2FP060
5,8,10,15,20,25
24
-
1600
49.0
36.8
12.30
-
10.95
F2FV060
8,10,15,20,25
24
-
1600
50.5
37.9
13.10
-
11.90
H4DH060S06
F2FP060
5,8,10,15,20,25
24
-
1900
59.0
44.3
12.00
-
10.90
F2FV060
8,10,15,20,25
24
-
1780
59.0
44.3
-
12.40
11.40
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.