PART NAMES

CAUTIONS

1.  If air conditioner is used outside of the above conditions, 

certain safety protection features may come into operation 
cause the unit to function abnormally.

2.  Room relative humidity less than 80%. If the air conditioner 

operates in excess of this 

fi

 gure, the surface of the air conditioner 

may attract condensation. Please sets the vertical air 

fl

 ow 

louver to its maximum angle (Vertically to the 

fl

 oor), and 

set HIGH fan mode.

3.  Optimum performance will be achieved within these 

operating temperature.

INDOOR UNIT

OUTDOOR UNIT

  INDOOR & OUTDOOR UNIT

  DISPLAY PANEL

1

  

AUTO indicator

 

This indicator illuminates when the air conditioner is in AUTO 
operation.

2

  

DEFROST indicator (For Cooling & Heating models only)

 

This indicator illuminates when the air conditioner starts 
defrosting automatically or when the warm air control feature 
is activated in heating operation.

3

  

TEMPERATURE indicator

 

Displays the temperature settings when the air conditioner is 
operational.

4

  

OPERATION indicator

 This 

indicator 

fl

 ashes after power is on and illuminates when 

the unit is in operation.

5

 

TIMER indicator

 

This indicator illuminates when TIMER is set ON/OFF.

NOTE

All the pictures in this manual are for explanation purpose 
only. They may be slightly different from the air conditioner 
your purchased. The actual shape shall prevail.

OPERATING TEMPERATURE

DISPLAY PANEL

1

22

3

4

5

DEFROST

DEFROST

TIMER

TIMER

AUTO

AUTO

OPERATION

OPERATION

Signal receptor

8

  Remote controller signal 

 receiver

9

  Remote controller

0

  Manual control button

-

  Connecting pipe, drain hose

=

  Air inlet (side and rear)

~

  Air outlet

1

  Front panel

2

  Air inlet

3

  Air 

fi

 lter

4

  Air outlet

5

  Horizontal air 

fl

 ow grille

6

  Vertical air 

fl

 ow louver

7

  Display panel

Mode

Temperature

Cooling

operation

Heating

operation

Drying

operation

Room temperature

17°C-32°C

17°C-30°C

17°C-32°C

Outdoor 
temperature

18°C-43°C

-7°C-24°C

18°C-43°C

J277-EN.indd   4

J277-EN.indd   4

26.12.2005   15:15:14 Uhr

26.12.2005   15:15:14 Uhr

Summary of Contents for RLCA-RLHA 07-30

Page 1: ...ELS RLCA RLHA 07 30 RLCB RLHB 07 28 RACC RAHC 07 28 MINISPLIT HIGH WALL AIR CONDITIONER EN 035M80147 000 The units comply with one or more of the following marks see unit for details J277 EN 1 J277 EN...

Page 2: ...tent reli ability in product service and support through superior quality service culture and distinctive technology R22 R407C 50Hz 60Hz 50Hz Set RLCAxxFSAAAR RLCAxxFSAADR RLCBxxFSAAAR RLHAxxFSAAAR RL...

Page 3: ...ous and can cause injury Installation and maintenance of this air conditioning system should only be carried out by trained and qualified personnel After unpacking please check the unit carefully for...

Page 4: ...ERATURE indicator Displays the temperature settings when the air conditioner is operational 4 OPERATION indicator This indicator flashes after power is on and illuminates when the unit is in operation...

Page 5: ...conditioner will automatically increase cooling or decrease heating 1 C per hour The set temperature will be steady 2 hours later The fan speed will be automatically controlled DRYING OPERATION The d...

Page 6: ...ord and the main breaker capacity are sufficient and the installation area is sufficient and complies with the requirements Check that the power supply available agrees with name plate voltage Electri...

Page 7: ...48 115 90 266 272 298 285 290 530 110 62 590 750 RLDA RLJA 07 09 RLDB RLJB 07 09 RADC RAJC 07 RLDA RLJA 12 18 RLDB RLJB 12 RADC RAJC 09 12 RLDA RLJA 24 30 RLDB RLJB 24 28 RADC RAJC 18 28 RLDB RLJB 18...

Page 8: ...tres or more from the floor A B and C directions should be free from obstructions NOTES This illustration is for explanation purposes only Copper lines must be insulated independently C B A 1 2 3 5 4...

Page 9: ...l Carefully arrange pipes so that pipes do not stick out of the rear plate of the indoor unit A B C D E F MODEL 24 30 Right Right Right Right Left Rear Bottom Drain hose Drain hose is flexible and can...

Page 10: ...smitted to the building struc ture Connect the pipe correctly Do not apply the excessive torque Use an appropriate bending tool to form curves and avoid over tightening the refrigerant tubes To preven...

Page 11: ...rs Liquid Cooling GAS Cooling suction Low pressure High pressure Manifold Gas valve Liquid valve Pressure tap Outdoor unit Indoor unit Gas line Liquid line R22 R407C R410A Outdoor heat pump unit insta...

Page 12: ...isconnecting device must have a contact separation of at least 3 mm Models 07 18 Cooling only Power supply Indoor L N 1 2 N 1 2 N Outdoor CAUTIONS Models 07 18 Cooling and Heating L N 1 2 N 3 4 1 2 N...

Page 13: ...1 2 N S L N Terminal block of indoor unit Cooling only type cooling heating type Terminal block of indoor unit Cord clamp To outdoor unit To outdoor unit Terminal block of outdoor unit Wire holding b...

Page 14: ...50Hz 32A 220 230V 60Hz NOTE b Unit has been running at high temperature protection mode for 90 minute High temperature protection mode when coil temperature of indoor unit reaches 55 C outdoor unit w...

Page 15: ...the unit 2 Stop the air conditioner and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourse...

Page 16: ...condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off sme...

Page 17: ...s tem 1 Remove charge repair evacuate and recharge 2 Insulate them separately 3 Wait while unit has enough time to cool the room D The compressor runs con tinuously 1 Thermostat adjustment too low in...

Page 18: ...Hz 220 240 1 50 Ph 1 1 1 1 1 1 Fan Air flow m3 h 400 400 450 450 580 580 800 800 1080 1080 1150 1150 Input Power W 39 5 39 5 39 5 39 5 38 5 38 5 53 53 65 65 70 70 Running Current A 0 17 0 17 0 17 0 1...

Page 19: ...0 14 0 14 0 14 0 14 0 24 0 24 0 68 0 68 0 34 0 34 Dimension Height mm 250 250 250 250 265 265 292 292 330 330 330 330 Width mm 710 710 710 710 790 790 920 920 1080 1080 1080 1080 Depth mm 190 190 190...

Page 20: ...Running Current A 0 17 0 17 0 17 0 17 0 2 0 2 0 26 0 26 0 37 0 37 0 32 0 32 Dimension Height mm 250 250 250 250 265 265 292 292 330 330 330 330 Width mm 710 710 710 710 790 790 920 920 1080 1080 1080...

Page 21: ...65 65 70 70 Running Current A 0 17 0 17 0 17 0 17 0 2 0 2 0 26 0 26 0 37 0 37 0 32 0 32 Dimension Height mm 250 250 250 250 265 265 292 292 330 330 330 330 Width mm 710 710 710 710 790 790 920 920 108...

Page 22: ...ces should refrigerant be vented to atmosphere Where appropriate drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulations governing d...

Reviews: