Be careful when handling the sharp edge of the mount-
ing plate.
■
Wiring
•
This indoor unit is ready for connection to the outdoor unit.
•
Never modify the unit by removing any of the safety
guards or by passing any of the safety interlock swith-
ces.
•
Connect the interconnecting cable correctly and con-
nect the connecting cable to terminal as identi
fi
ed with
their respective marking.
•
Do not damage the conductor core or inner insulation
of power supply cables and do not deform or crush
the cables.
■
Piping
The auxiliary piping can be connected in the diections
shown the above diagram. To connect in the
D
,
E
and
F
direction, pipes will need to be extended.
•
Bend pipes carefully to avoid
fl
attening or obstructing
them if the pipes are bent incorrectly, the indoor unit
may be unstable on the wall.
•
Carefully arrange pipes so that pipes do not stick out
of the rear plate of the indoor unit.
A
B
C
D
E
F
MODEL 24-30
Right
Right
Right
Right
Left
Rear Bottom
■
Drain hose
•
Drain hose is
fl
exible and can be routed to suit vari-
ous piping arrangements. The drain line must include
elbow trap (U bend). Connect a plastic condensate
pipe with an internal diameter of 12 mm.
•
The drain hose can be connected to the left or the right
side.
Veri
fi
cation of condensate water drainage:
Fill the drain pan with water and observe evacuation.
Note: Do not put the drain hose end into water.
Drain hose
For left and left rear piping (Factory standard)
Drain cap
Drain cap
Drain hose
For right connection
CAUTION
Above 150mm from the ceiling
Hooked Part
Indoor Unit Outline
Hooked Part
Pipe hole
Above 120mm from
the wall
432
58
465
465
115
50
Pipe hole
58
50
115
Hooked Part
432
1080
Above 120mm from
the wall
330
108
22
95
95