246824-YTG-G-1208
Johnson Controls Unitary Products
25
115°F
125°F
1875
77
88.0
8.6
32.3
29.4
21.4
-
-
-
83.1
9.4
29.2
25.0
18.8
-
-
-
72
79.6
8.5
49.9
41.9
34.0
26.0
-
-
73.9
9.4
46.9
39.1
31.2
23.3
-
-
67
71.1
8.5
67.5
54.5
46.5
38.6
30.6
-
64.6
9.3
64.6
51.5
43.6
35.7
27.8
-
62
67.4
8.5
67.4
67.4
54.3
46.3
38.3
30.4
62.8
9.3
62.8
62.8
49.1
41.2
33.3
25.5
2250
77
90.0
8.6
42.5
33.1
23.7
-
-
-
84.4
9.4
41.4
30.3
20.9
-
-
-
72
81.4
8.5
56.4
47.1
37.7
28.3
-
-
75.0
9.4
53.5
44.1
34.7
25.3
-
-
67
72.8
8.5
70.4
61.0
51.6
42.2
32.9
-
65.6
9.3
65.6
57.9
48.5
39.1
29.7
-
62
69.0
8.5
69.0
69.0
60.2
50.8
41.4
32.1
63.8
9.3
63.8
63.8
54.7
45.3
35.9
26.5
57
70.4
8.5
70.4
69.8
60.4
51.0
41.6
32.3
65.2
9.3
65.2
64.3
54.5
45.1
35.7
26.3
2625
77
92.1
8.6
52.7
36.9
26.1
-
-
-
85.6
9.4
53.6
35.6
23.0
-
-
-
72
83.3
8.5
63.0
52.2
41.4
30.6
-
-
76.1
9.4
60.1
49.1
38.2
27.3
-
-
67
74.5
8.5
73.3
67.5
56.7
45.9
35.1
-
66.5
9.3
66.5
64.3
53.4
42.5
31.6
-
62
70.5
8.5
70.5
70.5
66.2
55.4
44.6
33.8
64.7
9.3
64.7
64.7
60.2
49.3
38.4
27.4
57
72.0
8.5
72.0
71.7
66.4
55.6
44.8
34.0
66.1
9.3
66.1
65.7
60.0
49.1
38.2
27.3
3000
77
94.1
8.6
63.0
40.6
28.4
-
-
-
86.9
9.4
65.9
41.0
25.2
-
-
-
72
85.1
8.5
69.5
57.3
45.1
32.9
-
-
77.1
9.4
66.6
54.2
41.7
29.3
-
-
67
76.1
8.5
76.1
74.0
61.8
49.6
37.4
-
67.4
9.3
67.4
67.4
58.3
45.9
33.4
-
62
72.1
8.5
72.1
72.1
72.1
59.9
47.7
35.5
65.6
9.3
65.6
65.6
65.6
53.3
40.9
28.4
57
73.6
8.5
73.6
73.6
72.3
60.1
47.9
35.7
67.1
9.3
67.1
67.1
65.6
53.1
40.7
28.2
3375
72
85.6
8.5
74.6
61.4
48.1
34.9
-
-
77.7
9.4
71.4
58.0
44.6
31.2
-
-
67
76.6
8.5
76.6
75.5
66.0
52.7
39.5
-
67.8
9.3
67.8
67.8
62.3
48.9
35.6
-
62
72.5
8.5
72.5
72.5
72.5
59.3
46.1
32.9
66.0
9.4
66.0
66.0
66.0
52.7
39.3
25.9
57
74.0
8.5
74.0
74.0
73.4
60.2
47.0
33.7
67.5
9.4
67.5
67.5
66.8
53.4
40.0
26.6
3750
72
86.2
8.6
79.6
65.4
51.2
36.9
-
-
78.2
9.4
76.2
61.8
47.5
33.2
-
-
67
77.1
8.5
77.1
77.1
70.1
55.9
41.7
-
68.3
9.4
68.3
68.3
66.4
52.0
37.7
-
62
73.0
8.5
73.0
73.0
73.0
58.8
44.5
30.3
66.5
9.4
66.5
66.5
66.5
52.1
37.8
23.5
57
74.5
8.5
74.5
74.5
74.5
60.3
46.0
31.8
68.0
9.4
68.0
68.0
68.0
53.6
39.3
24.9
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZH090 (7.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65