background image

5331896-YTG-C-1017

4

Johnson Controls Unitary Products

ACCESSORIES

Propane Conversion Kit (S1-1NP0703, S1-1NP0704) -

 Kit 

includes burner orifices, gas valve conversion and installa-
tion instructions necessary to field convert unit from natural 
gas to propane.

Economizer for Downflow Applications  
(S1-2EE04710024, S1-2EE04710124) - 

Modulating inte-

grated economizer provides simultaneous operation 
between the mechanical cooling and economizer operation. 
Independent blade design insures proper control and less 
than 1% leak rate. Includes hood and mesh bird screen filter 
integrated into the hood, dry bulb sensor and relief damper. 
Separate field accessories of single enthalpy and dual 
enthalpy are also available.

Economizer for Horizontal Applications  
(S1-2EE04710224, S1-2EE04710324) - 

Modulating inte-

grated economizer provides simultaneous operation 
between the mechanical cooling and economizer operation. 
Independent blade design insures proper control and less 
than 1% leak rate. Includes hood and mesh bird screen filter 
integrated into the hood, dry bulb sensor and relief damper. 
Separate field accessories of single enthalpy and dual 
enthalpy are also available.

Single/Dual Enthalpy Sensor (S1-HE-6863-0N00WS) -

Sensor replaces supply air temperature dry bulb sensor 
standard in economizer kit. Provides improved economizer 
operation by sensing the dry bulb temperature of indoor sup-
ply air plus the enthalpy content of the outdoor air.

Duct/Unit Mount CO2 Kit (S1-2AQ04700924) -

 Sensor kit 

detects CO2 levels automatically and overrides the econo-
mizer when CO2 levels rise above the preset limits.

Wall Mount CO2 Kit (S1-2AQ04701024) -

 Sensor kit 

detects CO2 levels automatically and overrides the econo-
mizer when CO2 levels rise above the preset limits.

• Supply Air Temperature Sensor Kit (S1-TE-63616E-2D) - 

Outdoor supply air temperature sensor kit used with econo-
mizers. 

Filter/Frame Kit (S1-1FF0602, S1-1FF0601) - 

Kit contains 

the necessary hardware to field install return air filters into 
the base unit. The filter rack is suitable for either 1" or 2" fil-
ters.

Filter (S1-02647812000) - 

Washable 1" filter. Two filters are 

required for A base units. Three filters are required for B 
base units.

Motorized Fresh Air Damper  
(S1-2MD04705224, S1-2MD04705124) -

 Designed for duct 

mounted side supply/return and unit mounted down supply/
return applications. Damper capable of providing 0% through 
50% of outdoor air (field supplied). Closes on power loss, 
includes hood and screen assembly.

Rectangle to Round (Horizontal) Adapter  
(S1-1AK0110, S1-1AK0111) -

 Kit includes one supply and 

one return air rectangle to round duct adapter. Adapters are 
preformed and designed to fit over current horizontal duct 
openings on the base unit. Transition is from rectangle to 12" 
round for the 1AK0110 kit and from rectangle to 14" round for 
the 1AK0111 kit.

Rectangle to Round (Downflow) Adapter  
(S1-1AK0108, S1-1AK0109) -

 Kit includes one supply and 

one return air rectangle to round duct adapter. Adapters are 
preformed and designed to fit into current downflow duct 
openings on the roof curb. Transition is from rectangle to 16" 
round for the 1AK0108 kit and from rectangle to 18" round for 
the 1AK0109 kit.

Roof Curbs (S1-1RC0503, S1-1RC0501) -

 NRCA approved 

curbs provide proper fit to base unit for rooftop installations. 
Curbs are designed to be assembled through hinge pins in 
each corner. Kit also provides seal strip to assure an air tight 
seal. These are 8 inch high roof curbs.

Roof Curbs (S1-1RC0504, S1-1RC0502) -

 NRCA approved 

curbs provide proper fit to base unit for rooftop installations. 
Curbs are designed to be assembled through hinge pins in 
each corner. Kit also provides seal strip to assure an air tight 
seal. These are 14 inch high roof curbs.

Transition Curb Kits (S1-1TC01*) -

 Adapter  kits  to  allow 

field use of pre-existing installed roof curbs to match PHG6 
footprint to Affinity roof curbs, Carrier, Trane, or Goodman 
curb footprints. Curb adapters are optional for current gener-
ation Carrier replacements but are recommended for previ-
ous generation applications. Refer to the PHG6 price pages 
for more details.

Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) -

Provides 0% through 50% outdoor air capability (field adjust-
able). Designed for duct mounted side supply/return applica-
tions. Includes hood and screen assembly.

• Thermostat

 

(S1-THXU280*) - 

Compatible thermostat con-

trols are available through accessory sourcing. For optimum 
performance, these outdoor units are fully compatible with 
the York Hx™ Touchscreen Thermostat (S1-THXU280*) 
available through Source1. For more information, see the 
thermostat section of the Product Equipment Catalog.

Wall Thermostat - 

The units are designed to operate with 

standard, 24-volt electronic and electro-mechanical thermo-
stats. All units must operate with a two-stage heat/two-stage 
cool heat pump thermostat able to control fossil fuel opera-
tion - with or without the economizer. 

Loss of Charge Switch (S1-2LC00024) -

 Kit provides loss 

of charge switch and wiring to provide safe shutdown of com-
pressor.

Low Ambient Kit (S1-2LA04701024) -

 Kit provides neces-

sary hardware to convert unit to operate in cooling cycle 
down to 0º F. Standard unit operation 45º F.

Base Rail Hole Cover Kit (S1-1HC0101) -

 Kit provides nec-

essary hardware to close off openings in base rails to block 
off openings, i.e. prevent animal entrance.

For additional kit numbers refer to the price pages.

Summary of Contents for PHG6A24

Page 1: ...t and tested prior to shipment Test sta tions using a state of the art computerized process system are used to insure product quality Refrigerant charge and component part numbers are verified via com...

Page 2: ...ed The electrical control box is not located in the compressor compartment The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affect...

Page 3: ...minal Capacity etc 9 Revision Level A original release B second release Examples PHG4B421002X1 is a dual fuel 14 SEER 3 1 2 ton large cabinet single stage heat 100 000 BTU gas heat 230 volt single pha...

Page 4: ...e to round duct adapter Adapters are preformed and designed to fit over current horizontal duct openings on the base unit Transition is from rectangle to 12 round for the 1AK0110 kit and from rectangl...

Page 5: ...it Condensate pan shall be internally sloped and conform to ASHRAE 62 89 self draining standards with 3 4 NPT female ridged mount connection Durable Finish The cabinet shall be is made of G90 galva ni...

Page 6: ...l be of the tubular type constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 F Burners shall be of the in shot type constructed of aluminu...

Page 7: ...burners 2 3 2 3 2 3 2 3 2 3 4 2 3 4 No stages 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Temperature Rise Range High Fire F 40 70 40 70 40 70 40 70 40 70 40 70 Temperature Rise Range Low Fire F 20 50 20 50 25 55 25...

Page 8: ...gal Centrifugal Centrifugal Centrifugal Motor HP each 1 3 1 2 1 3 1 2 1 2 3 4 3 4 3 4 1 RPM 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max Frame size 48 48 48 48 48 48 Filters Filter Size A A B...

Page 9: ...6 6 9 0 7 1 7 9 8 5 7 9 K W 1 71 1 71 1 70 1 69 1 68 1 64 1 64 1 64 1 63 1 62 1 57 1 56 1 58 1 57 1 55 COOLING PERFORMANCE DATA 2 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6A24 CONDENSER ENTERING AIR...

Page 10: ...9 2 8 9 10 1 8 2 11 6 8 8 8 1 10 3 9 1 K W 2 55 2 54 2 54 2 53 2 51 2 54 2 53 2 53 2 53 2 50 2 53 2 51 2 53 2 53 2 50 COOLING PERFORMANCE DATA 2 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6A30 CONDEN...

Page 11: ...5 16 1 14 3 14 9 11 2 15 7 17 5 16 6 17 4 12 8 K W 2 68 2 67 2 68 2 66 2 64 2 62 2 61 2 63 2 61 2 58 2 56 2 56 2 58 2 56 2 53 COOLING PERFORMANCE DATA 3 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B36...

Page 12: ...3 19 1 16 9 17 9 12 8 22 7 19 9 18 9 20 4 14 1 K W 3 04 3 03 3 02 3 02 2 97 3 03 3 02 3 03 3 02 2 98 3 03 3 02 3 04 3 03 3 00 COOLING PERFORMANCE DATA 3 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B4...

Page 13: ...3 2 20 0 17 4 20 8 14 3 24 4 22 1 18 8 23 3 16 0 K W 4 16 4 16 4 15 4 15 4 09 4 11 4 12 4 14 4 11 4 07 4 06 4 08 4 12 4 06 4 04 COOLING PERFORMANCE DATA 4 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B48...

Page 14: ...6 7 24 9 21 6 23 2 16 7 27 1 24 7 22 6 24 6 17 6 K W 4 79 4 77 4 78 4 74 4 70 4 78 4 77 4 78 4 75 4 71 4 78 4 77 4 79 4 75 4 72 COOLING PERFORMANCE DATA 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B60...

Page 15: ...DOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 550 750 950 MBH COP KW MBH COP KW MBH COP KW 60 60 28 9 4 46 1 83 30 1 4 96 1 69 31 4 5 51 1 55 70 27 5 3 87 2 01 28 7 4 30 1 86 29 9 4 80 1 71 80 26 2 3...

Page 16: ...IT AIR TEMP ENTERING INDOOR COIL ID CFM 750 950 1150 MBH COP KW MBH COP KW MBH COP KW 60 60 38 5 4 76 2 13 37 5 4 60 2 22 36 6 4 44 2 30 70 36 5 4 15 2 34 35 7 3 99 2 44 34 8 3 83 2 55 80 34 6 3 63 2...

Page 17: ...UTDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1000 1200 1400 MBH COP KW MBH COP KW MBH COP KW 60 60 43 9 4 52 2 53 43 0 4 45 2 58 42 0 4 37 2 64 70 42 1 4 01 2 76 41 2 3 94 2 82 40 3 3 87 2 88 80 4...

Page 18: ...UTDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1070 1270 1470 MBH COP KW MBH COP KW MBH COP KW 60 60 47 0 4 42 2 80 46 5 4 36 2 89 46 1 4 30 2 98 70 44 7 3 86 3 07 44 3 3 81 3 17 43 9 3 76 3 26 80 4...

Page 19: ...TDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1300 1500 1700 MBH COP KW MBH COP KW MBH COP KW 60 60 61 4 4 63 3 46 60 8 4 52 3 56 60 1 4 42 3 68 70 58 7 4 04 3 82 58 2 3 93 3 97 57 7 3 82 4 12 80 56...

Page 20: ...TDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1530 1730 1930 MBH COP KW MBH COP KW MBH COP KW 60 60 73 6 4 77 4 15 73 1 4 56 4 18 72 5 4 37 4 21 70 70 6 4 22 4 53 70 2 4 03 4 60 69 8 3 85 4 67 80 67...

Page 21: ...within a confined space and recirculate Direction Distance in Direction Distance in Top3 3 Units must be installed outdoors Over hanging structure or shrubs should not obstruct condenser air discharge...

Page 22: ...ne Frequency Hz 125 250 500 1000 2000 4000 8000 PHG6A24 70 3 64 7 59 2 59 8 58 1 54 3 49 2 43 2 PHG6A30 69 0 57 5 58 0 58 0 63 8 53 2 47 6 49 7 PHG6B36 72 8 60 1 62 5 60 4 64 5 58 8 53 0 46 0 PHG6B42...

Page 23: ...453 28 15 161 102 90 100 PHG6B36065 503 498 29 14 176 122 104 96 PHG6B36100 510 505 29 14 178 123 109 95 PHG6B42065 537 532 29 14 190 132 112 98 PHG6B42100 539 534 29 14 191 133 109 101 PHG6B48065 556...

Page 24: ...237 192 Low Cool A 902 822 764 713 669 612 557 513 480 437 B 855 734 669 615 572 509 454 418 385 334 C 827 678 611 545 504 448 396 356 311 263 D 675 546 466 404 347 277 205 160 126 80 High Heat A 118...

Page 25: ...A 1126 1067 1006 945 860 777 718 664 608 551 B 1015 952 884 802 709 646 582 528 467 402 C 955 886 821 721 642 584 508 453 391 324 D 910 836 774 661 592 537 453 396 333 265 Low Heat A 970 902 837 742...

Page 26: ...704 1667 1645 1612 1572 1520 1477 1419 1384 1327 B 1506 1468 1441 1404 1358 1302 1259 1203 1159 1101 C 1322 1278 1238 1191 1138 1077 1030 975 920 859 D 1251 1205 1157 1107 1051 987 938 884 824 761 Low...

Page 27: ...4 930 872 810 High Heat A 2114 2046 1974 1914 1874 1815 1745 1696 1645 1582 B 1982 1930 1887 1844 1806 1752 1697 1643 1604 1545 C 1785 1746 1720 1687 1647 1596 1551 1494 1459 1402 D 1614 1578 1554 152...

Page 28: ...75 1329 1280 1232 1181 1135 C 1410 1361 1307 1255 1204 1155 1100 1044 992 938 D 1323 1270 1213 1156 1104 1052 993 933 880 821 Low Heat A 1594 1553 1507 1462 1415 1369 1321 1274 1223 1178 B 1323 1270 1...

Page 29: ...06 0 02 0 16 1300 0 07 0 03 0 17 1400 0 08 0 04 0 18 42 3 5 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08...

Page 30: ...N REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A032 UNIT TYPICAL SLAB ON GROUND INSTALLATION A0325 001 SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCON...

Page 31: ...roducts 31 UNIT TYPICAL ROOF CURB INSTALLATION SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPLY LINE MANUAL GAS SHUTOF...

Page 32: ...change without notice Published in U S A 5331896 YTG C 1017 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes 5331896 YTG B 0817 York International Corp 5005 York Drive Norman OK 7...