background image

5331896-YTG-C-1017

2

Johnson Controls Unitary Products

Full Perimeter Base Rails -

 The easily removable base rails 

provide a solid foundation for the entire unit and protects the 
unit during shipment. The rails provide fork lift access from 
all sides, and rigging holes are also provided so that an over-
head crane can be used to place the units on a roof. On 
applications where the unit is placed on a pad, the base will 
keep the unit off the pad to deter corrosion. On applications 
where height is limited, the base rails may be removed by 
removing 2 screws in each corner.

More Attractive Appearance -

 A single-piece  top  cover 

containing a top-discharge outdoor fan arrangement requires 
less square footage on installation and provides a wider vari-
ety of installations. The one-piece design adds greater water 
integrity. Rounded corners with water drip edges add to the 
attractive appearance.

Top Discharge -

 The top-discharge outdoor fan does not 

disrupt neighboring areas or dry out vegetation surrounding 
the unit. The warm air from the top mounted fan is blown up 
and away from the structure and any landscaping. This 
allows compact location on multi-unit applications.

Outdoor Coil Grille -

 All models utilize a stamped slotted 

design which provides superior impact protection against 
small objects during transit and after installation.

Low Operating Sound Level -

 The upward air flow carries 

the normal operating noise up and away from the living area. 
The rigid top panel effectively isolates noise. Isolator 
mounted compressor and the rippled fins of the outdoor coil 
muffle the normal fan motor and compressor operating 
sounds. The unique formed base pan also aids in sound 
attenuation with its structural design. This design strategi-
cally places embossments in the pan for optimum strength 
and rigidity.

Fan System -

 All  models  operate  over  a  wide  range  of 

design conditions with an enhanced ECM indoor fan motor. 
These units easily match all types of applications and pro-
vide greater on-site flexibility to match comfort requirements. 
The cooling speed is factory-set and can be field-adjusted to 
a alternate speed. The heating speed is factory set to main-
tain mid point rise at the units heating input, but can be field 
adjusted. This allows maximum comfort conditions.

Simple Control Circuit -

 A low voltage gas heat printed cir-

cuit board contains a status/diagnostic indicator light. Field 
thermostat wiring connects to color coded leads using twist 
on wire connectors. Cooling controls use contactor and 
relays for simple application and troubleshooting. Mate-n-
lock plug connectors are used. The electrical control box is 
not located in the compressor compartment. The controls are 
mounted to allow the separate access panel to be removed 
for trouble shooting and maintenance without affecting the 
normal system operating pressures. All wiring internal to the 
unit is color/number coded.

Controls - 

Demand defrost curves are pre-loaded into the 

demand defrost control for optimized performance based on 
unit capabilities.

Protected Compressor -

 The compressor is internally pro-

tected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high pres-
sure internal relief valve and a temperature sensor which 
protect the compressor if undesirable operating conditions 
occur.

Pressure Switches -

 A high pressure switch is standard in 

all units. When abnormal conditions are sensed through the 
pressure switch, the unit will lock out preventing any further 
operation until reset or problem is corrected.

Exclusive Coil Design -

 Grooved copper tubes and 

enhanced aluminum fin construction improves heat transfer 
for maximum efficiency and durability for long-lasting durabil-
ity and efficient operation. Indoor coils use tin-coated copper 
tubing with aluminum fins for effective heat transfer.

Heat Exchangers -

 Gas heat exchangers use corrosion-

resistant, stainless-steel tubular construction to provide long-
life, trouble-free operation. Gas heat exchangers are offered 
with lifetime warranties as standard with registration.

Post Purge Induced Draft Combustion -

 Exhausts com-

bustion products from the heat exchanger upon completion 
of the heating cycle to prolong the heat exchanger life.

Spark To Burner Ignition -

 No pilot assembly required, 

which provides more consistent ignition in gas heating mode. 
This ignition system is highly reliable, durable and eliminates 
nuisance lockouts.

Multi Port In-shot Burners -

 No field adjustment is required 

to mix the air and gas for natural gas or propane use. These 
burners are constructed of high-grade corrosion-resistant, 
aluminumized steel.

Low Maintenance -

 Long life, permanently lubricated out-

door and indoor fan motor bearings need no annual mainte-
nance, adding greater reliability to the unit. Slide-out blower 
assembly can be easily removed for cleaning.

Easy Service Access -

 Individual access panels covering 

the electrical and gas controls, compressor, and blower sec-
tion makes servicing easy. Removing this panel will allow 
easy removal of the blower assembly for maintenance and 
ease of troubleshooting.

Replacement Parts -

 The installer requires no special train-

ing to replace any of the components of these units and the 
number of new components have been reduced to minimize 
the inventory of unique parts.

Loss of Charge Switch -

 All models include a loss of charge 

switch to provide safe shutdown of compressor.

Summary of Contents for PHG6A24

Page 1: ...t and tested prior to shipment Test sta tions using a state of the art computerized process system are used to insure product quality Refrigerant charge and component part numbers are verified via com...

Page 2: ...ed The electrical control box is not located in the compressor compartment The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affect...

Page 3: ...minal Capacity etc 9 Revision Level A original release B second release Examples PHG4B421002X1 is a dual fuel 14 SEER 3 1 2 ton large cabinet single stage heat 100 000 BTU gas heat 230 volt single pha...

Page 4: ...e to round duct adapter Adapters are preformed and designed to fit over current horizontal duct openings on the base unit Transition is from rectangle to 12 round for the 1AK0110 kit and from rectangl...

Page 5: ...it Condensate pan shall be internally sloped and conform to ASHRAE 62 89 self draining standards with 3 4 NPT female ridged mount connection Durable Finish The cabinet shall be is made of G90 galva ni...

Page 6: ...l be of the tubular type constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 F Burners shall be of the in shot type constructed of aluminu...

Page 7: ...burners 2 3 2 3 2 3 2 3 2 3 4 2 3 4 No stages 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Temperature Rise Range High Fire F 40 70 40 70 40 70 40 70 40 70 40 70 Temperature Rise Range Low Fire F 20 50 20 50 25 55 25...

Page 8: ...gal Centrifugal Centrifugal Centrifugal Motor HP each 1 3 1 2 1 3 1 2 1 2 3 4 3 4 3 4 1 RPM 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max Frame size 48 48 48 48 48 48 Filters Filter Size A A B...

Page 9: ...6 6 9 0 7 1 7 9 8 5 7 9 K W 1 71 1 71 1 70 1 69 1 68 1 64 1 64 1 64 1 63 1 62 1 57 1 56 1 58 1 57 1 55 COOLING PERFORMANCE DATA 2 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6A24 CONDENSER ENTERING AIR...

Page 10: ...9 2 8 9 10 1 8 2 11 6 8 8 8 1 10 3 9 1 K W 2 55 2 54 2 54 2 53 2 51 2 54 2 53 2 53 2 53 2 50 2 53 2 51 2 53 2 53 2 50 COOLING PERFORMANCE DATA 2 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6A30 CONDEN...

Page 11: ...5 16 1 14 3 14 9 11 2 15 7 17 5 16 6 17 4 12 8 K W 2 68 2 67 2 68 2 66 2 64 2 62 2 61 2 63 2 61 2 58 2 56 2 56 2 58 2 56 2 53 COOLING PERFORMANCE DATA 3 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B36...

Page 12: ...3 19 1 16 9 17 9 12 8 22 7 19 9 18 9 20 4 14 1 K W 3 04 3 03 3 02 3 02 2 97 3 03 3 02 3 03 3 02 2 98 3 03 3 02 3 04 3 03 3 00 COOLING PERFORMANCE DATA 3 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B4...

Page 13: ...3 2 20 0 17 4 20 8 14 3 24 4 22 1 18 8 23 3 16 0 K W 4 16 4 16 4 15 4 15 4 09 4 11 4 12 4 14 4 11 4 07 4 06 4 08 4 12 4 06 4 04 COOLING PERFORMANCE DATA 4 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B48...

Page 14: ...6 7 24 9 21 6 23 2 16 7 27 1 24 7 22 6 24 6 17 6 K W 4 79 4 77 4 78 4 74 4 70 4 78 4 77 4 78 4 75 4 71 4 78 4 77 4 79 4 75 4 72 COOLING PERFORMANCE DATA 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B60...

Page 15: ...DOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 550 750 950 MBH COP KW MBH COP KW MBH COP KW 60 60 28 9 4 46 1 83 30 1 4 96 1 69 31 4 5 51 1 55 70 27 5 3 87 2 01 28 7 4 30 1 86 29 9 4 80 1 71 80 26 2 3...

Page 16: ...IT AIR TEMP ENTERING INDOOR COIL ID CFM 750 950 1150 MBH COP KW MBH COP KW MBH COP KW 60 60 38 5 4 76 2 13 37 5 4 60 2 22 36 6 4 44 2 30 70 36 5 4 15 2 34 35 7 3 99 2 44 34 8 3 83 2 55 80 34 6 3 63 2...

Page 17: ...UTDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1000 1200 1400 MBH COP KW MBH COP KW MBH COP KW 60 60 43 9 4 52 2 53 43 0 4 45 2 58 42 0 4 37 2 64 70 42 1 4 01 2 76 41 2 3 94 2 82 40 3 3 87 2 88 80 4...

Page 18: ...UTDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1070 1270 1470 MBH COP KW MBH COP KW MBH COP KW 60 60 47 0 4 42 2 80 46 5 4 36 2 89 46 1 4 30 2 98 70 44 7 3 86 3 07 44 3 3 81 3 17 43 9 3 76 3 26 80 4...

Page 19: ...TDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1300 1500 1700 MBH COP KW MBH COP KW MBH COP KW 60 60 61 4 4 63 3 46 60 8 4 52 3 56 60 1 4 42 3 68 70 58 7 4 04 3 82 58 2 3 93 3 97 57 7 3 82 4 12 80 56...

Page 20: ...TDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1530 1730 1930 MBH COP KW MBH COP KW MBH COP KW 60 60 73 6 4 77 4 15 73 1 4 56 4 18 72 5 4 37 4 21 70 70 6 4 22 4 53 70 2 4 03 4 60 69 8 3 85 4 67 80 67...

Page 21: ...within a confined space and recirculate Direction Distance in Direction Distance in Top3 3 Units must be installed outdoors Over hanging structure or shrubs should not obstruct condenser air discharge...

Page 22: ...ne Frequency Hz 125 250 500 1000 2000 4000 8000 PHG6A24 70 3 64 7 59 2 59 8 58 1 54 3 49 2 43 2 PHG6A30 69 0 57 5 58 0 58 0 63 8 53 2 47 6 49 7 PHG6B36 72 8 60 1 62 5 60 4 64 5 58 8 53 0 46 0 PHG6B42...

Page 23: ...453 28 15 161 102 90 100 PHG6B36065 503 498 29 14 176 122 104 96 PHG6B36100 510 505 29 14 178 123 109 95 PHG6B42065 537 532 29 14 190 132 112 98 PHG6B42100 539 534 29 14 191 133 109 101 PHG6B48065 556...

Page 24: ...237 192 Low Cool A 902 822 764 713 669 612 557 513 480 437 B 855 734 669 615 572 509 454 418 385 334 C 827 678 611 545 504 448 396 356 311 263 D 675 546 466 404 347 277 205 160 126 80 High Heat A 118...

Page 25: ...A 1126 1067 1006 945 860 777 718 664 608 551 B 1015 952 884 802 709 646 582 528 467 402 C 955 886 821 721 642 584 508 453 391 324 D 910 836 774 661 592 537 453 396 333 265 Low Heat A 970 902 837 742...

Page 26: ...704 1667 1645 1612 1572 1520 1477 1419 1384 1327 B 1506 1468 1441 1404 1358 1302 1259 1203 1159 1101 C 1322 1278 1238 1191 1138 1077 1030 975 920 859 D 1251 1205 1157 1107 1051 987 938 884 824 761 Low...

Page 27: ...4 930 872 810 High Heat A 2114 2046 1974 1914 1874 1815 1745 1696 1645 1582 B 1982 1930 1887 1844 1806 1752 1697 1643 1604 1545 C 1785 1746 1720 1687 1647 1596 1551 1494 1459 1402 D 1614 1578 1554 152...

Page 28: ...75 1329 1280 1232 1181 1135 C 1410 1361 1307 1255 1204 1155 1100 1044 992 938 D 1323 1270 1213 1156 1104 1052 993 933 880 821 Low Heat A 1594 1553 1507 1462 1415 1369 1321 1274 1223 1178 B 1323 1270 1...

Page 29: ...06 0 02 0 16 1300 0 07 0 03 0 17 1400 0 08 0 04 0 18 42 3 5 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08...

Page 30: ...N REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A032 UNIT TYPICAL SLAB ON GROUND INSTALLATION A0325 001 SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCON...

Page 31: ...roducts 31 UNIT TYPICAL ROOF CURB INSTALLATION SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPLY LINE MANUAL GAS SHUTOF...

Page 32: ...change without notice Published in U S A 5331896 YTG C 1017 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes 5331896 YTG B 0817 York International Corp 5005 York Drive Norman OK 7...

Reviews: