background image

5331896-YTG-C-1017

Johnson Controls Unitary Products

25

30075

High Cool

A 1152

1128

1090

1049

1005

958

917

876

834

788

B 1076

1047

1011

967

912

875

833

790

734

707

C 1023

991

950

903

850

813

767

719

664

640

D 910

837

780

729

685

631

576

529

495

453

Low Cool

A 982

946

899

849

801

761

710

656

609

581

B 927

867

813

761

717

667

612

561

524

487

C 870

761

699

649

605

539

484

449

422

370

D 813

650

582

510

470

417

367

325

274

227

High Heat

A 1184

1161

1124

1084

1041

994

954

913

872

822

B 1076

1047

1011

967

912

875

833

790

734

707

C 992

957

912

863

813

774

724

672

622

596

D 927

867

813

761

717

667

612

561

524

487

Low Heat

A 1205

1182

1145

1107

1065

1019

979

938

896

845

B 1076

1047

1011

967

912

875

833

790

734

707

C 992

957

912

863

813

774

724

672

622

596

D 902

822

764

713

669

612

557

513

480

437

36065

High Cool

A 1371

1354

1303

1257

1209

1148

1084

1008

934

878

B 1293

1246

1206

1152

1098

1028

938

865

813

767

C 1232

1178

1131

1077

1012

929

853

790

738

690

D 1058

999

931

859

762

694

635

582

523

459

Low Cool

A 1153

1095

1036

979

899

810

751

697

643

588

B 1015

952

884

802

709

646

582

528

467

402

C 882

805

741

625

556

501

415

359

297

228

D 805

718

642

523

436

376

294

247

193

118

High Heat

A 1126

1067

1006

945

860

777

718

664

608

551

B 1015

952

884

802

709

646

582

528

467

402

C 955

886

821

721

642

584

508

453

391

324

D 910

836

774

661

592

537

453

396

333

265

Low Heat

A 970

902

837

742

659

599

527

472

410

343

B 818

732

659

540

456

397

314

265

211

136

C 766

674

593

473

377

314

234

190

142

63

D 721

625

540

413

314

251

172

131

102

53

36100

High Cool

A 1374

1333

1298

1255

1204

1145

1100

1044

993

933

B 1304

1260

1218

1170

1116

1055

1007

953

896

834

C 1233

1186

1137

1085

1029

965

915

861

799

736

D 1063

1006

937

871

806

735

678

628

550

484

Low Cool

A 1120

1067

1004

944

882

813

758

707

635

569

B 1025

966

892

823

756

684

625

575

494

427

C 882

812

716

633

559

480

412

366

270

199

D 821

746

641

552

475

392

321

276

174

101

High Heat

A 1704

1667

1645

1612

1572

1520

1477

1419

1384

1327

B 1506

1468

1441

1404

1358

1302

1259

1203

1159

1101

C 1322

1278

1238

1191

1138

1077

1030

975

920

859

D 1251

1205

1157

1107

1051

987

938

884

824

761

Low Heat

A 1392

1352

1318

1276

1226

1168

1123

1067

1017

957

B 1251

1205

1157

1107

1051

987

938

884

824

761

C 1139

1087

1027

968

907

839

785

733

663

598

D 984

922

841

769

700

625

564

515

430

361

Table continued on next page. See NOTES at end of table.

AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued)

Model

Jumper Position

External Static Pressure (Inches WC)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

Summary of Contents for PHG6 24 Series

Page 1: ...t and tested prior to shipment Test sta tions using a state of the art computerized process system are used to insure product quality Refrigerant charge and component part numbers are verified via com...

Page 2: ...ed The electrical control box is not located in the compressor compartment The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affect...

Page 3: ...minal Capacity etc 9 Revision Level A original release B second release Examples PHG4B421002X1 is a dual fuel 14 SEER 3 1 2 ton large cabinet single stage heat 100 000 BTU gas heat 230 volt single pha...

Page 4: ...e to round duct adapter Adapters are preformed and designed to fit over current horizontal duct openings on the base unit Transition is from rectangle to 12 round for the 1AK0110 kit and from rectangl...

Page 5: ...it Condensate pan shall be internally sloped and conform to ASHRAE 62 89 self draining standards with 3 4 NPT female ridged mount connection Durable Finish The cabinet shall be is made of G90 galva ni...

Page 6: ...l be of the tubular type constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 F Burners shall be of the in shot type constructed of aluminu...

Page 7: ...burners 2 3 2 3 2 3 2 3 2 3 4 2 3 4 No stages 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Temperature Rise Range High Fire F 40 70 40 70 40 70 40 70 40 70 40 70 Temperature Rise Range Low Fire F 20 50 20 50 25 55 25...

Page 8: ...gal Centrifugal Centrifugal Centrifugal Motor HP each 1 3 1 2 1 3 1 2 1 2 3 4 3 4 3 4 1 RPM 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max 1200 Max Frame size 48 48 48 48 48 48 Filters Filter Size A A B...

Page 9: ...6 6 9 0 7 1 7 9 8 5 7 9 K W 1 71 1 71 1 70 1 69 1 68 1 64 1 64 1 64 1 63 1 62 1 57 1 56 1 58 1 57 1 55 COOLING PERFORMANCE DATA 2 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6A24 CONDENSER ENTERING AIR...

Page 10: ...9 2 8 9 10 1 8 2 11 6 8 8 8 1 10 3 9 1 K W 2 55 2 54 2 54 2 53 2 51 2 54 2 53 2 53 2 53 2 50 2 53 2 51 2 53 2 53 2 50 COOLING PERFORMANCE DATA 2 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6A30 CONDEN...

Page 11: ...5 16 1 14 3 14 9 11 2 15 7 17 5 16 6 17 4 12 8 K W 2 68 2 67 2 68 2 66 2 64 2 62 2 61 2 63 2 61 2 58 2 56 2 56 2 58 2 56 2 53 COOLING PERFORMANCE DATA 3 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B36...

Page 12: ...3 19 1 16 9 17 9 12 8 22 7 19 9 18 9 20 4 14 1 K W 3 04 3 03 3 02 3 02 2 97 3 03 3 02 3 03 3 02 2 98 3 03 3 02 3 04 3 03 3 00 COOLING PERFORMANCE DATA 3 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B4...

Page 13: ...3 2 20 0 17 4 20 8 14 3 24 4 22 1 18 8 23 3 16 0 K W 4 16 4 16 4 15 4 15 4 09 4 11 4 12 4 14 4 11 4 07 4 06 4 08 4 12 4 06 4 04 COOLING PERFORMANCE DATA 4 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B48...

Page 14: ...6 7 24 9 21 6 23 2 16 7 27 1 24 7 22 6 24 6 17 6 K W 4 79 4 77 4 78 4 74 4 70 4 78 4 77 4 78 4 75 4 71 4 78 4 77 4 79 4 75 4 72 COOLING PERFORMANCE DATA 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PHG6B60...

Page 15: ...DOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 550 750 950 MBH COP KW MBH COP KW MBH COP KW 60 60 28 9 4 46 1 83 30 1 4 96 1 69 31 4 5 51 1 55 70 27 5 3 87 2 01 28 7 4 30 1 86 29 9 4 80 1 71 80 26 2 3...

Page 16: ...IT AIR TEMP ENTERING INDOOR COIL ID CFM 750 950 1150 MBH COP KW MBH COP KW MBH COP KW 60 60 38 5 4 76 2 13 37 5 4 60 2 22 36 6 4 44 2 30 70 36 5 4 15 2 34 35 7 3 99 2 44 34 8 3 83 2 55 80 34 6 3 63 2...

Page 17: ...UTDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1000 1200 1400 MBH COP KW MBH COP KW MBH COP KW 60 60 43 9 4 52 2 53 43 0 4 45 2 58 42 0 4 37 2 64 70 42 1 4 01 2 76 41 2 3 94 2 82 40 3 3 87 2 88 80 4...

Page 18: ...UTDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1070 1270 1470 MBH COP KW MBH COP KW MBH COP KW 60 60 47 0 4 42 2 80 46 5 4 36 2 89 46 1 4 30 2 98 70 44 7 3 86 3 07 44 3 3 81 3 17 43 9 3 76 3 26 80 4...

Page 19: ...TDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1300 1500 1700 MBH COP KW MBH COP KW MBH COP KW 60 60 61 4 4 63 3 46 60 8 4 52 3 56 60 1 4 42 3 68 70 58 7 4 04 3 82 58 2 3 93 3 97 57 7 3 82 4 12 80 56...

Page 20: ...TDOOR UNIT AIR TEMP ENTERING INDOOR COIL ID CFM 1530 1730 1930 MBH COP KW MBH COP KW MBH COP KW 60 60 73 6 4 77 4 15 73 1 4 56 4 18 72 5 4 37 4 21 70 70 6 4 22 4 53 70 2 4 03 4 60 69 8 3 85 4 67 80 67...

Page 21: ...within a confined space and recirculate Direction Distance in Direction Distance in Top3 3 Units must be installed outdoors Over hanging structure or shrubs should not obstruct condenser air discharge...

Page 22: ...ne Frequency Hz 125 250 500 1000 2000 4000 8000 PHG6A24 70 3 64 7 59 2 59 8 58 1 54 3 49 2 43 2 PHG6A30 69 0 57 5 58 0 58 0 63 8 53 2 47 6 49 7 PHG6B36 72 8 60 1 62 5 60 4 64 5 58 8 53 0 46 0 PHG6B42...

Page 23: ...453 28 15 161 102 90 100 PHG6B36065 503 498 29 14 176 122 104 96 PHG6B36100 510 505 29 14 178 123 109 95 PHG6B42065 537 532 29 14 190 132 112 98 PHG6B42100 539 534 29 14 191 133 109 101 PHG6B48065 556...

Page 24: ...237 192 Low Cool A 902 822 764 713 669 612 557 513 480 437 B 855 734 669 615 572 509 454 418 385 334 C 827 678 611 545 504 448 396 356 311 263 D 675 546 466 404 347 277 205 160 126 80 High Heat A 118...

Page 25: ...A 1126 1067 1006 945 860 777 718 664 608 551 B 1015 952 884 802 709 646 582 528 467 402 C 955 886 821 721 642 584 508 453 391 324 D 910 836 774 661 592 537 453 396 333 265 Low Heat A 970 902 837 742...

Page 26: ...704 1667 1645 1612 1572 1520 1477 1419 1384 1327 B 1506 1468 1441 1404 1358 1302 1259 1203 1159 1101 C 1322 1278 1238 1191 1138 1077 1030 975 920 859 D 1251 1205 1157 1107 1051 987 938 884 824 761 Low...

Page 27: ...4 930 872 810 High Heat A 2114 2046 1974 1914 1874 1815 1745 1696 1645 1582 B 1982 1930 1887 1844 1806 1752 1697 1643 1604 1545 C 1785 1746 1720 1687 1647 1596 1551 1494 1459 1402 D 1614 1578 1554 152...

Page 28: ...75 1329 1280 1232 1181 1135 C 1410 1361 1307 1255 1204 1155 1100 1044 992 938 D 1323 1270 1213 1156 1104 1052 993 933 880 821 Low Heat A 1594 1553 1507 1462 1415 1369 1321 1274 1223 1178 B 1323 1270 1...

Page 29: ...06 0 02 0 16 1300 0 07 0 03 0 17 1400 0 08 0 04 0 18 42 3 5 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08...

Page 30: ...N REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A032 UNIT TYPICAL SLAB ON GROUND INSTALLATION A0325 001 SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCON...

Page 31: ...roducts 31 UNIT TYPICAL ROOF CURB INSTALLATION SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPLY LINE MANUAL GAS SHUTOF...

Page 32: ...change without notice Published in U S A 5331896 YTG C 1017 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes 5331896 YTG B 0817 York International Corp 5005 York Drive Norman OK 7...

Reviews: