PREPARATION BEFORE INSTALLATION
• Before doing any work, check the interior power supply cord and the main breaker capacity are sufficient and the
installation area is sufficient and complies with the requirements.
• Check that the power supply available agrees with nameplate voltage.
• Electrical work, wiring and cables must be performed in compliance with national and local wiring codes and
standard.
• Do not use the extension cables. In the case extended cables are needed, use the terminal block.
SELECTION OF THE LOCATION
• Select a place which provides the space around the units as shown in the diagram below.
Models
MHC-MHH/BOC-BOH
07
09
12
18
25
A
60cm
60cm
60cm
60cm
60cm
B
70cm
70cm
70cm
70cm
70cm
C
60cm
60cm
60cm
60cm
60cm
D
10cm
10cm
10cm
10cm
10cm
Models
MHC-MHH/BOC-BOH
07
09
12
18
25
A
20cm
20cm
20cm
20cm
20cm
B
60cm
60cm
60cm
60cm
60cm
C
40cm
40cm
40cm
40cm
40cm
D
20cm
20cm
20cm
20cm
20cm
Outdoor
Cautions
• Do not install in a place that cannot bear the weight of the unit.
Indoor
BO 07-12
BO 18
BO 25
497
133.5
133.5
248
230
268
429
150
550
150
100
100
64
64
234
315
287
24
24
335
517
144
144
296
260
316
02_MHC/BOH 07-25.p65
18/3/02, 16:31
6
Summary of Contents for MHC-MHH
Page 18: ...18 HIGH WALL...