York MCC Technical Manual Download Page 3

3

Unit dimensions are shown in the Technical Specifications table above.

Outdoor Unit : MOC/MOH 09-18

C

B

E

A

D

           Outdoor Unit : MOC/MOH 25

W

D

H

H

D

W

Indoor Unit : MCC/MCH 09-25

1

1.25

5.7

29

10

590

920/1,050

1/2"
1/4"

655/492
990/764
199/230

26/38

1

2.4

11.3

53
16

710

1,620

5/8"
3/8"

655/590
990/820
199/280

27/59

1

1.01

5

21.5

10

490

900/1,000

3/8"
1/4"

655/492
990/764
199/230

26/36

V/Ph/Hz

Ph

kW

A
A

A

m /h

Type

gr.

Suction

Liquid

H(mm)

W(mm)

D(mm)

kg

1

3.14
14.5

70
20

840

1,750

5/8"
3/8"

655/696
990/850
199/287

29/65

 

3

Models

Power Supply

Power Consumption

Nominal Current

Starting  Current
Fuse Size

Indoor Airflow (high speed)

Indoor

unit

Outdoor

unit

V/Ph/Hz

Ph

kW

A
A
A

m /h

09

09

1

0.99

4.6

21

10

490

12

12

1

1.30

6.1

28

10

580

18

18

1

1.89

8.7

43

16

700

Refrigerant
Refrigerant Charge (MOC/MOH)

Piping

Dimensions and Weights

Indoor/Outdoor

Connection Type

Indoor Airflow (high speed)

Power Supply

208-230/1/60

Compressor

Starting  Current
Fuse Size

Nominal Current

Power Consumption

Expansion Device

System Operation Control

Compressor

         

 

Wired or Wireless Remote Control with LCD Display

Capillary Tube

R22

Rotary

Rotary

Reciprocating

Reciprocating

220-240/1/50 or 380-415/3/50

3

2.73

5.4

34

10

25

25

820

1

2.80

13.2

68

20

  

3

             

Flare and Nuts

Diameter

MOC - MOH

MCC - MCH

3 - Technical Specifications

4 - Dimensions

Summary of Contents for MCC

Page 1: ...MOC MOH MCC MCH MINISPLIT Floor Ceiling TECHNICAL GUIDE Cooling only and Heat Pump Systems Models MCC MOC MCH MOH 09 to 25 Infrared remote control 035 T 700049 001...

Page 2: ...make sure that the power supply has been disconnected ELECTRICAL CONNECTIONS All electrical wiring and connections must comply with local standards Power supply cord used must not be lighter than Poly...

Page 3: ...Nominal Current Starting Current Fuse Size Indoor Airflow high speed Indoor unit Outdoor unit V Ph Hz Ph kW A A A m h 09 09 1 0 99 4 6 21 10 490 12 12 1 1 30 6 1 28 10 580 18 18 1 1 89 8 7 43 16 700...

Page 4: ...clearances A minimium of clearance is necessary around the units to ensure proper air circulation and easy access for maintenance Clearance required for indoor units Clearance required for outdoor uni...

Page 5: ...urely tighten the hex bolts on both sides Disassemble the side panels and the air inlet grill as shown First open the grill then remove the side panel installation screws Slide the panel toward the to...

Page 6: ...Pa 3 When pump down is finisned wait 15 minutes to detect potential circuit leakage Open service valves on the outdoor unit Note The expansion device is located in the outdoor unit 6 Table 2 Maximum p...

Page 7: ...point entered on the control SYSTEM OPERATION MODE SELECTION ROOM TEMPERATURE SETTING Press the TEMP button up or down to change the setting to the desired room temperature The setting range is from 1...

Page 8: ...ityofthebatteries and that they are in good working condition Also make sure that the controlispointeddirectlyattheairconditioningunitwhenyouareusing it that the distance is a maximum of 10 meters and...

Page 9: ...it 9 The units are designed to operate for long periods of time with a minimum of maintenance However the following operations must be performed regularly RECOMMENDED FREQUENCY MAINTENANCE OPERATIONS...

Page 10: ...nt kit 8 C Inlet air wet bulb temperature indo or unit CWB 10 15 20 25 30 35 20 25 30 35 40 Air intake dry bulb temperature outdoor unit CDB Capacity correction factor C1 Operating temperature range 1...

Page 11: ...35 MSC 35 to 55 MSH 35 to 55 MKC 12 to 55 MKH 12 to 55 MAC 18 to 55 MAH 18 to 55 IS IN COMPLIANCE WITH REQUIREMENTS OF MACHINERY DIRECTIVE CEE 89 392 AS MODIFIED WITH DIRECTIVES CEE 91 368 93 44 93 6...

Page 12: ...the unit into a suitable container using a refrigerant reclaim or recovery unit This refrigerant may then be re used if appropriate or returned to the manufacturer for disposal Under No circumstances...

Reviews: