335224-BIM-B-1208
Johnson Controls Unitary Products
23
TABLE 10: ELECTRICAL DATA - DK-10 W/O PWRD CONVENIENCE OUTLET
TABLE 11: ELECTRICAL DATA - DK-10 W/PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
2
3
2
3
2
3
2
3
2
3
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
51.2
53.9
56.7 59.4
60
60
70
70
2TP04521825
13.5
37.5
57.1
60.5
64.0 67.3
60
70
70
70
2TP04522425
18
50.0
72.7
76.1
79.6 83.0
80
80
80
90
2TP04523625
25.5
70.8
98.7
102.1 105.6 109.0 100 110
110
110
2TP04525425 40.6
112.7 151.1 154.5 158.0 161.4 175 175
175
175
None
--
--
51.2
53.9
56.7 59.4
60
60
70
70
2TP04521825
18
43.3
64.4
67.8
71.3 74.6
70
70
80
80
2TP04522425
24
57.7
82.4
85.8
89.3 92.7
90
90
90
100
2TP04523625
34
81.8
112.5 115.9 119.4 122.7 125 125
125
125
2TP04525425 54
129.9 140.2 143.5 147.0 150.4 150 175
175
175
None
--
--
26
27.2 28.2 29.4 30 35
35
35
2TP04521846
18
22.6
32.2 33.7 34.9 36.4 35 35
35
40
2TP04522446
24
30.1
41.2 42.7 44 45.5 45 45
45
50
2TP04523646
34
42.7
56.2 57.7 59 60.5 60 60
60
70
2TP04525446
54
67.8
70.1 71.6 72.8 74.3 80 80
80
80
None
--
--
20.6 21.1 22.4 22.9 25 25
25
25
2TP04521858
18
18.1
26.2 26.8 28.4 29 30 30
30
30
2TP04522458
24
24.1
33.4
34 35.6 36.2 35 35
40
40
2TP04523658
34
34.1
45.4
46 47.6 48.3 50 50
50
50
2TP04525458
54
54.2
56.5 57.1 58.7 59.3 70 70
70
70
*
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA
FLA
208
16.0
137.0
3.5
8.2
10.9
5.5
0.0
230
16.0
137.0
3.5
8.2
10.9
5.5
0.0
460
8.3
69.0
1.6
4.1
5.3
2.2
0.0
575
6.4
58.0
1.3
3.6
4.1
1.8
0.0
Maximum HACR breaker of the same AMP size is applicable.
RLA
LRA
FLA
2
3
2
3
2
3
2
3
2
3
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
61.2
63.9
66.7 69.4
70
70
80
80
2TP04521825
13.5
37.5
69.6
73.0
76.5 79.8
70
80
80
80
2TP04522425
18
50.0
85.2
88.6
92.1 95.5
90
90
100
100
2TP04523625
25.5
70.8
111.2 114.6 118.1 121.5 125 125
125
125
2TP04525425 40.6
112.7 163.6 167.0 170.5 173.9 175 175
175
175
None
--
--
61.2
63.9
66.7 69.4
70
70
80
80
2TP04521825
18
43.3
76.9
80.3
83.8 87.1
80
90
90
90
2TP04522425
24
57.7
94.9
98.3 101.8 105.2 100 100
110
110
2TP04523625
34
81.8
125.0 128.4 131.9 135.2 125 150
150
150
2TP04525425 54
129.9 152.7 156.0 159.5 162.9 175 175
175
175
None
--
--
31
32.2 33.2 34.4 35 40
40
40
2TP04521846
18
22.6
38.4 39.9 41.2 42.7 40 40
45
45
2TP04522446
24
30.1
47.5
49 50.2 51.7 50 50
60
60
2TP04523646
34
42.7
62.5
64 65.2 66.7 70 70
70
70
2TP04525446
54
67.8
76.3 77.8 79.1 80.6 90 90
90
90
None
--
--
24.6 25.1 26.4 26.9 30 30
30
30
2TP04521858
18
18.1
31.2 31.8 33.4 34 35 35
35
35
2TP04522458
24
24.1
38.4
39 40.6 41.2 40 40
45
45
2TP04523658
34
34.1
50.4
51 52.6 53.3 60 60
60
60
2TP04525458
54
54.2
61.5 62.1 63.7 64.3 70 70
70
70
*
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA
FLA
208
16.0
137.0
3.5
8.2
10.9
5.5
10.0
230
16.0
137.0
3.5
8.2
10.9
5.5
10.0
5.0
460
8.3
69.0
1.6
1.3
4.1
5.3
2.2
Maximum HACR breaker of the same AMP size is applicable.
3.6
4.1
1.8
4.0
575
6.4
58.0