1. Isolate all sources of electrical supply to the unit including any control system supplies switched by the unit. Ensure that all points of electrical and
gas isolation are secured in the OFF position. The supply cables and gas pipework may then be disconnected and removed. For points of
connection refer to unit installation instructions.
2.
2.
2.
2.
2. Remove all refrigerant from each system of the unit into a suitable container using a refrigerant reclaim or recovery unit. This refrigerant may then
be reused, if appropriate, or returned to the manufacturer for disposal. Under No circumstances should refrigerant be vented to atmosphere.
Under No circumstances should refrigerant be vented to atmosphere.
Under No circumstances should refrigerant be vented to atmosphere.
Under No circumstances should refrigerant be vented to atmosphere.
Under No circumstances should refrigerant be vented to atmosphere.
Where appropriate, drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulations
governing disposal of oily wastes.
3.
3.
3.
3.
3. Packaged unit can generally be removed in one piece after disconnection as above. Any fixing down bolts should be removed and then unit lifted
from position using the points provided and equipment of adequate lifting capacity. Reference MUST be made to the unit installation instructions
for unit weight and correct methods of lifting. Note that any residual or spilt refrigerant oil should be mopped up and disposed of as described above.
4.
4.
4.
4.
4. After removal from position the unit parts may be disposed of according to local laws and regulations.
INSTALLATION, REMOVAL AND DISPOSAL
INSTALLATION, REMOVAL AND DISPOSAL
INSTALLATION, REMOVAL AND DISPOSAL
INSTALLATION, REMOVAL AND DISPOSAL
INSTALLATION, REMOVAL AND DISPOSAL
This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury!
This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury!
This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury!
This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury!
This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury!
All work must only be carried out by competent persons using suitable protective clothing and safety precautions.
All work must only be carried out by competent persons using suitable protective clothing and safety precautions.
All work must only be carried out by competent persons using suitable protective clothing and safety precautions.
All work must only be carried out by competent persons using suitable protective clothing and safety precautions.
All work must only be carried out by competent persons using suitable protective clothing and safety precautions.
Read the Manual
Read the Manual
Read the Manual
Read the Manual
Read the Manual
Risk of electric shock
Risk of electric shock
Risk of electric shock
Risk of electric shock
Risk of electric shock
Unit is remotely controlled and
Unit is remotely controlled and
Unit is remotely controlled and
Unit is remotely controlled and
Unit is remotely controlled and
may start without warning
may start without warning
may start without warning
may start without warning
may start without warning
YORK
®
International Corporation
CM Choi
Shipping Manager
The product complies with the harmonized European safety standards and harmonized EMC standards listed above.
We have internal production control system that ensures compliance between the manufacturer products and the technical documentation.
The product is CE mark.
We declare under our sold responsibility that the equipment follows the provisions of the Directives stated above.
Authorized Representative:
Type of Equipment
Brand Name
Type Designation
Application of Council
Directive (s)
The following harmonized standards have been applied:
Standard (s)
EN 60335-2-40/A1:2000
EN 60335-2-40/A1:2000
EN 55014-1:2000/A2:2002
EN 55014-2:1997/A1:2001
EN 55022:1998/A1:2000
EN 61000-3-2:2000
EN 61000-3-3:1995/A1:2001
EN 61000-3-11:2000
EN 60825
EN 60335-1:1994+A11:1995+A1, A12:1996+A13, A14:1998+A15, A2:2000+A16:2001
EN 60335-2-40:1997+A1:2000
EN 55014-1:1993+A1:1997/A2:1999
EN 55104-2:1997
EN 61000-3-2:1995/A1:1998/A2:1998
EN 61000-3-2:1995/A14:2000
EN 61000-3-3:1995
EN 60335-2-40:2003
EN 50366:2003
DECLARATION OF CONFORMITY
YORK International (Northern Asia) Ltd.
15/F., Tower II, World Trade Square, 123 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong
Telephone: (852) 2331 9286 Fax: (852) 2331 9840
Technical Service Division: Telephone: (852) 2331 9286 Fax: (852) 2304 0068
Air Conditioners
YORK
HAEA-HADA07/09/12FS, HAEB-HADB07/09/12FS, HAEC-HADC07/09/12FS, HAKA-HAJA07/09/12FS,
HAKB-HAJB07/09/12FS, HAKC-HAJC07/09/12FS, HEEB-HEDB07/09/12/18/24/30FS,
HEKB-HEJB07/09/12/18/21/24/30FS, HLEA-HLDA07/09/12/18/24FS, HLCA-HLHA24/28/FS,
HMEA09MC/MD/ME, HMDA18MC, HMDA21MD, HMDA27ME, HMKB09MC/MD/ME/MF,
HMKB12MD/MF, HMJB18MC, HMJB21MD, HMJB27ME, HMJB30MF, HRKB09AB/AG/AH,
HRKB12AG, HRJB18AB, HRJB21AG, HRJB27AH, HRKA09AB, HRJA18AB,
HSKB-HSJB07/09/12/18/24FS, HTEA-HTDA18/21/24/30FS, HVKA-HVJA09/12/21/24AS,
HVKC-HVJC07/09/12DS, HVKC-HVJC18AS, PECA09/12FD,
PECB09/12/14FS, PESA09/12FD, PESB09/12/14FS, PLCA09FC/FD, PLCB09FC/FD,
PLSA09FC/FD, PLSB09FC/FD
MACC-MAHC07/09/12/18/24FS, MECB-MEHB07/09/12/18/24FS, MLCA-MLHA07/09/12/18/24FS,
MLCB-MLHB07/09/12/18/24FS
EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC and Machine Safety Directive: MSD 98/37/CE
J190
2/03/2005, 4:57 AM
20