P5417054
33
•
This “Individual Louver Setting” is NOT available when two wired controllers are used in the same
H-LINK. (This includes the combination with the wired controller and the wireless controller.)
•
The individual louver setting is available for up to 16 indoor units by single wired controller.
•
The individual louver settings with the same refrigerant cycle are available for up to four indoor units
without the communication cable for the wired controller.
4. Select the indoor unit to change the louver direction by
pressing “ ” and press “OK”.
(This screen is NOT displayed when only one indoor
unit is connected to the wired controller. In this case,
move to Item 5.)
5. Press “ ” and select the louver direction.
The selected louver is opened and the other louvers are
closed.
6. Press “Menu” while “Back/Help” is pressed.
The confirmation screen will be displayed.
7. Select “Yes” and press “OK”. Screen of Item 5. will be
displayed after the change of setting is confirmed.
If “No” is selected and “OK” is pressed, the screen will
return to Item 5.
▫
Regarding the “Individual Louver Setting”, the
louver selected at Item 5. will be set as “Number
1” and the other louver numbers will be changed
automatically as shown at right.
OK
Individual Louver Setting
01-01
01-02
01-03
Select unit to set.
01-04
Entr
Rtrn
Sel.
Back
OK
Individual Louver Setting:01-03
Adjust air direction & louver angle.
1
2
3
4
Adj.
Sel.
Entr
Rtrn
Back
Change louver outlet number?
(2 1, 3 2, 4 3, 1 4)
Louver Outlet Setting:01-03
Yes
No
Sel.
Entr
Rtrn
OK
Back
8.10 Control of Dew Condensation Prevention
This function limits the occurrence of condensation around louvers. Condensation can occur when the air
conditioner has run in cooling mode over a prolonged period of time at 80.6
o
F DB (27
o
C DB) and a high
rate of humidity (Relative Humidity: Approximately 80%). If there is any anticipation of upcoming operation
under these conditions, set optional function K8 to "01" on the function selection menu to safeguard against
condensation.
3. Select “Individual Louver Setting” from Individual Louver
Setting screen and press “OK”.
OK
Cancel INDV Louver SET
Individual Louver Setting
Individual Louver Setting
Entr
Rtrn
Sel.
Back