036-21023-005 Rev. A (0802)

Unitary Products Group

3

* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
**

Refer to Quick Selection Chart for specific furnace match-up.

ACCESSORIES*

Enhanced Coil Guard 

- An enhanced coil guard which offers

superior protection from hail and other types of damage is
available.
* For the most current accessory information, refer to the
price book or consult factory.

SOUND RATINGS*

*Rated in accordance with ARI Standard 270.

COOLING CAPACITY -With Air Handler Coils

UNIT 

MODEL

VAR SPEED AIR HANDLER

COIL MODEL

COOLING

MODEL

ELEC. HEAT 

KW

W

STAGE

(# CYL)

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

H4TS024

N+VSB12

5,7.5,10,15,18

17

G2FD024S17 

1

600

12.4

10.0

14.8

13.5

2

820

24.0

16.8

12.0

G2FD030S17 

1

600

12.8

10.2

15.4

14.0

2

820

24.6

17.2

12.5

G2FD036S17 

1

600

13.0

10.4

15.5

14.3

2

820

25.0

17.5

12.5

H4TS030

N-VSB12

5,7.5,10,15,18

17

G2FD030S17

1

670

15.0

12.0

14.0

12.7

2

1035

30.0

21.6

11.0

G2FD036S17

1

670

15.4

12.2

14.5

13.1

2

1035

31.0

22.0

11.0

N-VSC16

5,7.5,10,15,20

21

G2FD042S21

1

690

16.4

13.4

15.3

14.1

2

1065

31.6

23.4

11.2

H4TS036

N-VSC16

5,7.5,10,15,20

21

G2FD036S21

1

770

20.0

16.0

15.0

13.7

2

1185

35.0

26.0

11.3

G2FD042S21

1

770

20.0

16.0

15.0

13.7

2

1185

35.0

26.0

11.3

G2FD048S21

1

770

20.6

16.6

16.0

14.4

2

1185

36.0

26.6

12.5

H4TS048

N-VSC16

5, 7.5,10,15,20

21

G2FD048S21

1

1050

25.0

20.0

15.2

14.1

2

1605

47.5

35.0

10.4

N-VSD20

5, 7.5,10,15,20

24

G2FD048S24

1

1050

25.0

20.0

15.3

14.2

2

1570

47.5

35.0

10.5

G2FD060S24

1

1050

25.0

21.0

15.5

14.0

2

1570

49.5

37.0

10.7

H4TS060

N-VSD20

5, 7.5,10,15,20

 24

G2FD060S24

1

1250

33.0

26.4

14.5

13.5

2

1900

59.0

43.0

10.4

G2FD061H24

1

1250

33.0

26.4

15.0

14.0

2

1900

59.5

44.0

10.7

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

0

°F entering air temperature, 50% RH, and rated air flow.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.

UNIT MODEL

SOUND RATINGS 

DECIBELS

1 CYLINDER

2 CYLINDER

024

70 db

72 db

030

72 db

74 db

036

73 db

74 db

048

76 db

78 db

060

78 db

79 db

Summary of Contents for H4TS024

Page 1: ...ssor is protected against high and low pressure Hard start components are included to ensure start up under adverse conditions All models have standard crankcase heat for added protection OPTIMUM PERFORMANCE The solid state electronic con trolboard optimizes the compressor staging based on load requirements provides a 5 minute anti short cycle timer for the compressor and simplifies troubleshootin...

Page 2: ...P 1 1 1 1 1 FIN INCH 20 20 20 20 20 LIQUID LINE OD 3 8 3 8 3 8 3 8 3 8 VAPOR LINE OD 3 4 3 4 7 8 7 8 7 8 UNIT CHARGE LBS OZ 3 6 0 6 4 7 0 9 12 9 2 CHARGE PER FOOT OZ 68 68 70 70 70 OPERATING WEIGHT LBS 145 145 200 250 252 1 Rated in accordance with ARI Standard 110 utilizaton range A 2 Dual element fuses or HACR circuit breaker 3 The Unit Charge is correct for the outdoor unit matched indoor coil ...

Page 3: ...0 13 7 2 1185 35 0 26 0 11 3 G2FD042S21 1 770 20 0 16 0 15 0 13 7 2 1185 35 0 26 0 11 3 G2FD048S21 1 770 20 6 16 6 16 0 14 4 2 1185 36 0 26 6 12 5 H4TS048 N VSC16 5 7 5 10 15 20 21 G2FD048S21 1 1050 25 0 20 0 15 2 14 1 2 1605 47 5 35 0 10 4 N VSD20 5 7 5 10 15 20 24 G2FD048S24 1 1050 25 0 20 0 15 3 14 2 2 1570 47 5 35 0 10 5 G2FD060S24 1 1050 25 0 21 0 15 5 14 0 2 1570 49 5 37 0 10 7 H4TS060 N VSD...

Page 4: ...A048S17 1 670 15 0 12 2 14 0 12 7 2 1035 29 6 21 6 11 3 G2FD030S17 1 670 15 4 12 2 13 7 13 0 2 1035 29 8 21 6 11 0 G2FD036S17 1 670 15 0 12 0 14 1 13 2 2 1035 29 6 21 6 11 0 G2FD046S17 1 670 15 0 12 0 14 5 13 5 2 1035 29 6 21 6 11 2 P1XUC16V075 21 G1UA036S21 1 690 15 0 12 0 14 5 13 0 2 1065 29 6 21 6 11 0 G1FA036S21 1 690 15 0 12 0 14 5 13 0 2 1065 29 6 21 6 11 0 G1UA048S21 1 690 15 4 12 2 14 5 13...

Page 5: ...5 5 14 2 2 1200 37 0 27 0 11 6 H4TS048 P1XUC16V075 P1XUC20V095 P1DUC20V096 21 G1UA048S21 1 1050 24 0 19 0 14 5 13 5 2 1500 47 5 35 0 10 2 G1FA048S21 1 1050 24 0 19 0 14 5 13 5 2 1500 47 5 35 0 10 2 G1UA060S21 1 1050 25 0 20 0 14 7 13 3 2 1500 49 0 36 0 10 4 G1FA060S21 1 1050 25 0 20 0 14 7 13 3 2 1500 49 0 36 0 10 4 G2FD048S21 1 1050 24 0 19 0 14 7 13 9 2 1500 47 5 35 0 10 2 P1XUD20V112 24 G1UA060...

Page 6: ...10 4 9 6 8 8 K W 0 99 0 97 0 96 0 94 1 00 0 97 0 96 0 95 1 02 1 00 0 99 0 98 115 T C 12 4 11 3 10 5 9 7 12 5 11 6 10 7 9 8 12 6 11 7 10 8 9 9 S C 9 5 9 4 8 8 8 1 9 9 9 7 8 9 8 2 10 4 9 8 9 0 8 3 K W 1 05 1 03 1 01 1 00 1 06 1 03 1 02 1 00 1 08 1 07 1 05 1 03 125 T C 11 5 10 5 9 8 9 1 11 6 11 0 10 0 9 2 11 8 11 0 10 1 9 2 S C 9 2 9 1 8 2 7 6 9 6 9 3 8 3 7 7 10 1 9 2 8 4 7 8 K W 1 10 1 09 1 06 1 06 ...

Page 7: ...9 18 0 K W 2 17 2 11 2 06 2 00 2 19 2 13 2 08 2 03 2 21 2 16 2 10 2 06 115 T C 23 9 21 9 19 9 18 0 24 1 22 0 20 0 18 4 24 2 22 3 20 2 18 7 S C 16 0 16 0 16 2 16 1 16 6 16 6 16 8 16 7 17 2 17 3 17 3 17 0 K W 2 30 2 23 2 16 2 11 2 32 2 25 2 19 2 13 2 34 2 28 2 21 2 17 125 T C 22 3 20 4 18 7 16 7 22 5 20 4 18 7 17 3 22 6 20 8 18 8 17 5 S C 15 5 15 5 15 7 15 5 16 0 16 1 17 2 19 1 16 7 16 8 16 7 16 0 K...

Page 8: ...2 6 11 5 14 8 13 6 12 6 11 6 15 1 14 0 12 8 11 8 S C 12 1 11 5 10 3 9 6 12 4 11 3 10 5 9 5 12 5 11 5 10 5 9 7 K W 1 40 1 37 1 35 1 32 1 42 1 40 1 37 1 36 1 47 1 46 1 41 1 40 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1VSB12 G2FD030S17 0 91 0 90 1 02 N1VSB12 G2FD036S17 0 94 0 91 1 01 N1VSC16 G2FD036S21 0 94 0 99 0 99 F2FP040 ...

Page 9: ...4 8 22 5 29 3 27 2 24 8 22 5 29 7 27 6 25 1 23 0 S C 21 3 21 1 21 7 21 7 21 7 21 9 22 0 22 1 23 0 23 1 23 3 23 2 K W 3 93 3 83 3 62 3 78 3 94 3 85 3 78 3 69 4 00 3 90 3 81 3 75 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1VSB12 G2FD030S17 0 95 0 92 0 97 N1VSB12 G2FD036S17 0 98 0 94 1 00 N1VSC16 G2FD036S21 0 98 0 99 1 00 F2FP0...

Page 10: ... 14 1 18 4 16 9 15 5 14 2 18 6 17 1 15 9 14 6 S C 14 8 14 6 14 7 13 5 15 5 15 4 15 3 13 7 16 8 16 7 15 2 14 1 K W 1 72 1 72 1 70 1 68 1 73 1 73 1 72 1 70 1 77 1 77 1 76 1 75 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1VSB12 G2FD036S17 0 91 0 96 1 03 N1VSC16 G2FD042S21 0 97 0 96 1 02 N1VSC16 G2FD036S21 0 97 0 96 1 02 N1VSD20 ...

Page 11: ... 7 24 1 32 4 29 9 27 0 25 1 32 9 29 8 27 2 25 4 S C 23 3 23 3 23 3 23 3 24 6 24 8 24 8 24 6 26 0 25 6 25 7 24 2 K W 3 46 3 40 3 30 3 20 3 51 3 43 3 33 3 27 3 55 3 48 3 39 3 32 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1VSB12 G2FD036S17 0 94 0 96 1 06 N1VSC16 G2FD036S21 0 97 0 98 1 07 N1VSC16 G2FD042S21 0 97 0 98 1 08 N1VSD2...

Page 12: ... 19 3 19 1 18 7 17 3 K W 1 92 1 88 1 85 1 83 1 95 1 92 1 89 1 86 1 99 1 95 1 93 1 90 125 T C 21 4 19 4 17 4 16 3 21 4 19 7 17 8 16 6 21 6 19 7 18 5 16 8 S C 16 8 16 6 16 5 15 5 17 8 17 5 17 5 15 9 18 7 18 4 17 5 16 1 K W 2 03 1 98 1 94 1 92 2 06 2 02 1 98 1 96 2 09 2 05 2 03 1 99 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1V...

Page 13: ... 34 1 34 0 34 5 34 4 K W 5 13 4 95 4 78 4 61 5 21 5 03 4 87 4 71 5 28 5 11 4 95 4 79 125 T C 42 9 39 2 35 8 32 2 43 2 39 5 36 0 33 0 43 6 39 7 36 4 33 3 S C 30 2 30 1 31 0 30 3 31 7 31 5 31 9 32 6 33 1 32 9 33 3 32 9 K W 5 41 5 20 4 83 4 82 5 49 5 28 5 11 4 94 5 55 5 37 5 19 5 01 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1V...

Page 14: ... 33 9 31 0 28 1 25 9 34 1 31 2 28 5 26 4 S C 24 4 24 4 24 6 24 6 25 7 25 6 25 8 25 1 26 9 26 8 27 0 25 5 K W 2 53 2 50 2 45 2 40 2 57 2 53 2 49 2 45 2 61 2 57 2 52 2 49 115 T C 31 4 28 7 26 0 23 9 31 7 28 9 26 4 24 4 31 9 29 1 26 8 24 8 S C 23 8 23 7 23 8 23 1 25 0 24 8 25 0 23 6 26 1 26 0 26 0 24 0 K W 2 71 2 66 2 59 2 54 2 75 2 70 2 64 2 59 2 79 2 74 2 68 2 63 125 T C 29 3 26 7 24 1 22 4 29 5 26...

Page 15: ...7 0 61 8 56 7 51 8 47 4 S C 40 6 40 7 41 0 40 9 42 7 42 7 43 4 43 5 44 0 44 1 44 5 44 5 K W 6 03 5 77 5 54 5 31 6 15 5 90 5 65 5 45 6 21 5 97 5 71 5 49 115 T C 57 2 52 3 47 6 43 2 57 9 53 1 48 4 44 2 58 0 53 4 48 6 45 2 S C 39 3 39 2 39 6 39 5 41 7 41 9 42 0 41 9 42 6 42 9 43 1 43 6 K W 6 39 6 10 5 84 5 58 6 50 6 23 5 94 5 72 6 57 6 28 6 01 5 83 125 T C 53 5 48 9 44 5 40 4 54 4 50 0 45 3 41 4 54 2...

Page 16: ...rk OK Group Drive 73069 MATCHING INDOOR COMPONENTS G1UA 1 2 CASED UPFLOW G2FD MULTI POSITION UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APPLICATIONS N AH OR N VS MODULAR BLOWER UPFLOW HORIZONTAL AND DOWNFLOW F RC F FC OR F RC F FP FAN COIL UNITS UPFLOW HORIZONTAL G FD...

Reviews: