COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL

1

MODEL

COOLING

MODEL

ELECTRIC 

2

HEAT KW

W

RATED 

CFM

NET MBH

SEER

W/O TXV

SEER 

+ TXV

3

EER

TOTAL SENS.

1 PH 12 SEER AC WITH N1AH / G2FD

H4AH024S06

N1AHB0806

2,5,8,10

17

G2FD024(S,H)17

850

24.0

18.0

12.00

-

10.80

H4AH024S06

N1AHB0806

2,5,8,10

17

G2FD030(S,H)17

850

24.2

18.3

12.00

-

10.70

H4AH030S06

N1AHB1206

5,8,10,15,19

17

G2FD030(S,H)17

1060

28.8

21.5

11.50

-

10.25

H4AH030S06

N1AHB1206

5,8,10,15,19

17

G2FD036(S,H)17

1060

30.2

22.6

12.00

-

10.50

H4AH036S06

N1AHB1206

5,8,10,15,19

17

G2FD036(S,H)17

1250

36.0

27.0

12.00

-

10.85

H4AH036S06

N1AHB1206

5,8,10,15,19

17

G2FD046(S,H)17

1250

35.6

26.8

12.00

-

10.90

H4AH036S06

N1AHD1406

5,8,10,15

24

G2FD048(S,H)24

1250

36.8

27.7

12.20

-

11.20

H4AH042S06

N1AHC1606

5,8,10,15,20

21

G2FD042(S,H)21

1350

40.5

30.0

12.00

-

11.00

H4AH042S06

N1AHC1606

5,8,10,15,20

21

G2FD048(S,H)21

1350

41.5

31.0

12.30

-

11.40

H4AH048S06

N1AHC1606

5,8,10,15,20

21

G2FD048(S,H)21

1620

48.0

35.3

12.20

-

11.30

H4AH048S06

N1AHD2006

8,10,15,20,25,30

24

G2FD060(S,H)24

1620

48.0

35.3

12.30

-

11.30

H4AH060S06

N1AHD2006

8,10,15,20,25,30

24

G2FD060(S,H)24

1850

59.0

43.4

12.00

-

10.50

H4AH060S06

N1AHD2006

8,10,15,20,25,30

24

G2FD061H24

1850

59.5

45.0

12.10

-

10.65

1 PH 12 SEER AC / N1VS - VARIABLE SPEED

H4AH024S06

N1VSB12

10,15,18

17

G2FD024(S,H)17

820

24.6

18.4

13.00

-

12.00

H4AH024S06

N1VSB12

10,15,18

17

G2FD036(S,H)17

820

24.6

18.7

13.00

-

12.20

H4AH030S06

N1VSB12

10,15,18

17

G2FD030(S,H)17

1035

29.2

22.0

12.30

-

11.30

H4AH030S06

N1VSB12

10,15,18

17

G2FD036(S,H)17

1070

30.8

23.3

13.00

-

11.40

H4AH036S06

N1VSB12

10,15,18

17

G2FD036(S,H)17

1250

36.4

27.1

12.60

-

11.40

H4AH036S06

N1VSB12

10,15,18

17

G2FD046(S,H)17

1230

36.0

27.3

12.50

-

11.50

H4AH036S06

N1VSC16

10,15,18

21

G2FD048(S,H)21

1220

37.4

28.3

13.50

-

12.10

H4AH042S06

N1VSC16

10,15,18

21

G2FD042(S,H)21

1350

41.0

30.6

13.00

-

11.80

H4AH042S06

N1VSC16

10,15,18

21

G2FD048(S,H)21

1350

42.0

31.3

13.30

-

12.20

H4AH048S06

N1VSC16

10,15,18

21

G2FD048(S,H)21

1590

48.5

36.1

12.90

-

11.90

H4AH048S06

N1VSD20

10,15,18,30

24

G2FD060(S,H)24

1600

48.0

36.1

13.00

-

11.85

H4AH060S06

N1VSD20

10,15,18,30

24

G2FD060(S,H)24

1600

58.5

44.5

12.55

-

10.90

H4AH060S06

N1VSD20

10,15,18,30

24

G2FD061H24

1600

59.0

45.7

12.65

-

11.10

1 PH 12 SEER AC / F2RP / RC / FP / FC / FV

4,5

H4AH024S06

F2RC/FC030

5,8,10,15

18

-

850

23.2

16.7

11.70

-

10.60

H4AH024S06

F2RP/FP024

5,8,10

18

-

850

24.0

18.0

12.00

-

10.80

H4AH024S06

F2RP/FP030

5,8,10,15

18

-

850

24.6

18.6

12.00

-

10.75

H4AH030S06

F2RC/FC036

5,8,10,15

21

-

1060

28.8

21.5

11.50

-

10.25

H4AH030S06

F2RP/FP030

5,8,10,15

18

-

1060

28.8

21.5

11.50

-

10.30

H4AH030S06

F2RP/FP036

5,8,10,15,19

18

-

1060

29.6

22.1

11.50

-

10.40

H4AH036S06

F2RP/FP036

5,8,10,15,19

21

-

1250

35.4

26.6

11.90

-

10.80

H4AH036S06

F2RP/FP042

5,8,10,15

21

-

1250

35.4

26.6

11.80

-

10.70

H4AH036S06

F2FP048

5,8,10,15,20,25

24

-

1250

36.6

27.5

12.00

-

10.90

H4AH042S06

F2RP/FP042

5,8,10,15

21

-

1350

40.5

30.0

12.00

-

10.90

H4AH042S06

F2FP045

5,8,10,15

24

-

1350

41.5

31.0

12.30

-

11.40

H4AH042S06

F2FP048

5,8,10,15,20,25

24

-

1350

41.0

30.6

12.00

-

11.20

H4AH042S06

F2FV060

8,10,15,20,25

24

-

1350

42.0

31.7

14.00

-

12.25

H4AH048S06

F2FP048

5,8,10,15,20,25

24

-

1620

47.5

34.9

12.00

-

11.00

H4AH048S06

F2FP060

5,8,10,15,20,25

24

-

1620

47.5

34.9

12.00

-

10.80

H4AH048S06

F2FV060

8,10,15,20,25

24

-

1605

48.5

36.1

13.50

-

12.50

H4AH060S06

F2FP060

5,8,10,15,20,25

24

-

1850

59.0

43.4

11.50

-

10.10

H4AH060S06

F2FV060

8,10,15,20,25

24

-

1860

60.5

44.5

13.00

-

11.50

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8

0

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input 
in watt-hours during the same period.

1

G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2

Single phase units require single phase 2HK heaters. 

3

TXV = Use 1TV700 Series Kit.

4

To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

models. All ratings remain the same.

5

FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.

Summary of Contents for H4AH024S06

Page 1: ... which protects the compressor if undesirable operating condi tions occur Additionally the unit has high and low pressure switch for extra protection against high pressure or loss of charge The compressor is protected by a 10 year limited warranty DURABLE FINISH Cabinet is made of powder painted steel over prepainted primer The pre treated flat galva nized steel provides a better paint to steel bo...

Page 2: ...urrent Device Amps 2 20 25 35 45 45 60 Compressor Type 3 Inertia Inertia ScrollC ScrollC ScrollC ScrollC Compressor Amps Rated Load 9 9 12 6 15 4 18 6 20 5 27 5 Locked Rotor 48 66 7 83 105 109 158 Crankcase Heater Yes Yes No No No No Fan Motor Amps Rated Load 0 86 0 86 1 2 1 2 1 2 1 2 Fan Diameter Inches 18 18 24 24 24 24 Fan Motor Rated HP 1 8 1 8 1 4 1 4 1 4 1 4 Nominal RPM 1050 1050 850 850 850...

Page 3: ...7 65 55 4 61 2 G2FD035 S H 14 65 55 4 61 2 G2FD036 S H 17 21 75 55 2 61 7 65 0 G2FD042 S H 21 78 65 5 69 10 G2FD046 S H 17 78 65 5 69 10 75 8 G2FD048 S H 21 24 84 67 13 69 12 75 10 G2FD060 S H 24 90 71 15 77 13 84 0 G2FD061H24 90 77 18 84 9 G1HD024 59 55 0 G1HD036 69 55 7 61 7 65 10 G1HD048 84 67 13 69 9 75 0 G1HD060 96 77 6 84 0 F2RC F2FC024 61 F2RC F2FC030 65 55 2 F2RC F2FC036 73 61 2 F2RP F2FP0...

Page 4: ... H 24 1600 48 0 36 1 13 00 11 85 H4AH060S06 N1VSD20 10 15 18 30 24 G2FD060 S H 24 1600 58 5 44 5 12 55 10 90 H4AH060S06 N1VSD20 10 15 18 30 24 G2FD061H24 1600 59 0 45 7 12 65 11 10 1 PH 12 SEER AC F2RP RC FP FC FV4 5 H4AH024S06 F2RC FC030 5 8 10 15 18 850 23 2 16 7 11 70 10 60 H4AH024S06 F2RP FP024 5 8 10 18 850 24 0 18 0 12 00 10 80 H4AH024S06 F2RP FP030 5 8 10 15 18 850 24 6 18 6 12 00 10 75 H4A...

Page 5: ... 11 35 10 10 14 G1FA036S14 1060 29 0 21 5 11 50 10 40 17 21 G1FA036S17 21 1060 28 8 21 5 11 50 10 25 G1HD036 1060 30 4 22 9 12 00 10 70 14 G1UA030S14 1060 28 4 21 2 11 35 10 10 14 G1UA036S14 1060 29 0 21 5 11 50 10 40 17 21 G1UA036S17 21 1060 28 8 21 5 11 50 10 25 17 G2FD030 S H 17 1060 28 8 21 5 11 50 10 25 14 G2FD035 S H 14 1060 28 8 21 5 11 50 10 25 17 G2FD036 S H 17 1060 30 2 22 6 12 00 10 50 ...

Page 6: ...0 59 0 43 4 12 00 10 50 G1HD060 1800 57 5 41 8 11 80 10 25 21 24 G1UA060S21 24 1850 59 0 43 4 12 00 10 50 24 G2FD060 S H 24 1850 59 0 43 4 12 00 10 50 24 G2FD061H24 1850 59 5 45 0 12 10 10 65 COOLING CAPACITY Upflow Downflow Horizontal Furnaces and Coils Continued UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE MIN MAX W RATED CFM NET MBH SEER W O TDR SEER TDR EER TOTAL SENS COOLING CAPACITY With ...

Page 7: ... 41 0 30 6 12 60 11 55 P1XUD20V G1FA060S24 24 1360 42 0 31 7 12 85 11 85 P1XUD20V G1UA060S24 24 1360 42 0 31 7 12 85 11 85 P1XUD20V G2FD048 S H 24 24 1360 42 0 31 3 12 75 11 80 H4AH048S06 P1DUB16V G1FA048S17 17 1500 47 0 32 3 13 00 11 90 P1DUB16V G1UA048S17 17 1500 47 0 32 3 13 00 11 90 P1DUC20V G1FA048S21 21 1610 47 0 35 5 12 40 11 40 P1DUC20V G1UA048S21 21 1610 47 0 35 5 12 40 11 40 P1DUC20V G2F...

Page 8: ...ent accessory information refer to the price book or consult factory SOUND RATINGS Rated in accordance with ARI Standard 270 TYPICAL INSTALLATION TYPICAL FIELD WIRING 1 Phase Application UNIT MODEL SOUND RATINGS DECIBELS WITH SOUND BLANKET WITHOUT SOUND BLANKET 024 72 76 030 74 79 036 76 76 042 76 75 048 77 78 060 80 81 THERMOSTAT TO INDOOR BLOWER TO COIL NEC CLASS 2 WIRING NEC CLASS 1 WIRING TO P...

Page 9: ...7 3 18 1 17 3 16 0 K W 2 38 2 33 2 27 2 22 2 41 2 36 2 30 2 25 2 43 2 38 2 32 2 27 115 T C 21 8 18 6 15 4 13 9 21 9 18 9 15 7 14 3 22 0 19 1 16 0 14 7 S C 15 9 15 8 15 0 13 4 16 4 16 4 15 3 13 8 16 9 16 9 15 6 14 1 K W 2 53 2 45 2 40 2 35 2 56 2 48 2 43 2 38 2 58 2 51 2 46 2 40 125 T C 19 7 16 2 12 8 12 1 19 8 16 3 13 1 12 5 19 8 16 7 13 5 13 0 S C 15 4 15 0 13 8 11 8 16 0 15 5 14 0 12 0 16 5 16 1...

Page 10: ... 2 96 2 87 3 21 3 13 3 02 2 94 115 T C 28 0 24 6 20 1 17 6 27 6 24 8 20 6 18 2 28 8 25 4 21 1 18 8 S C 19 8 19 5 18 5 17 2 21 4 20 2 19 6 17 9 21 8 21 9 20 7 18 5 K W 3 29 3 19 3 07 2 98 3 30 3 22 3 11 3 03 3 38 3 28 3 17 3 10 125 T C 25 9 21 8 17 0 15 1 24 6 21 8 17 4 15 7 26 5 22 5 17 8 16 3 S C 17 7 18 0 16 7 15 5 19 9 18 6 17 9 15 9 19 7 21 2 19 1 16 3 K W 3 48 3 35 3 22 3 13 3 46 3 37 3 26 3 ...

Page 11: ...99 125 T C 31 7 27 7 19 7 32 5 27 9 20 7 33 2 29 4 21 7 S C 27 5 25 1 20 4 27 1 25 0 21 9 26 7 25 6 23 3 K W 4 51 4 44 4 31 4 58 4 52 4 35 4 56 4 49 4 36 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHB1206 G2FD036 S H 17 1 00 1 00 1 00 N1AHB1206 G2FD046 S H 17 0 99 0 99 0 98 N1AHD1406 G2FD048 S H 24 1 02 1 03 0 99 N1VSB12 G2...

Page 12: ...3 4 07 3 98 3 94 4 26 4 19 4 11 4 07 115 T C 37 8 35 3 30 9 26 4 38 9 35 6 30 9 27 2 39 9 36 0 30 9 28 0 S C 29 0 25 5 26 6 25 2 31 0 27 2 28 4 26 9 33 0 29 0 30 3 28 5 K W 4 40 4 34 4 22 4 22 4 52 4 46 4 32 4 31 4 65 4 57 4 45 4 43 125 T C 35 0 32 9 28 3 23 7 36 4 33 2 28 0 24 6 37 7 33 4 27 7 25 5 S C 29 4 24 0 25 3 23 5 31 6 25 8 27 4 25 2 33 7 27 6 29 4 26 9 K W 4 79 4 72 4 57 4 61 4 91 4 85 4...

Page 13: ... 7 43 6 40 0 35 2 S C 32 6 31 5 30 9 34 1 33 1 32 5 35 6 34 7 34 0 K W 5 23 5 15 5 02 5 29 5 23 5 10 5 35 5 32 5 19 125 T C 37 2 34 1 30 3 37 9 34 2 30 8 38 4 34 4 31 3 S C 31 2 30 3 29 6 32 4 31 8 31 3 33 7 33 4 32 9 K W 5 75 5 69 5 46 5 82 5 77 5 56 5 89 5 86 5 67 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHC1606 G2FD048...

Page 14: ... 5 70 5 62 5 50 5 75 5 67 5 56 5 80 5 73 5 63 105 T C 59 7 55 6 49 8 60 3 56 2 50 5 60 9 56 7 51 1 S C 42 5 40 7 41 2 44 2 42 0 42 0 45 8 43 2 42 8 K W 6 36 6 25 6 09 6 41 6 31 6 16 6 46 6 37 6 24 115 T C 55 8 51 6 45 2 55 9 52 2 45 7 56 0 52 7 46 1 S C 41 4 39 2 38 7 42 9 40 9 40 0 44 4 42 6 41 3 K W 7 12 6 99 6 84 7 17 7 04 6 92 7 23 7 10 7 00 125 T C 51 9 47 6 40 6 51 5 48 2 40 9 51 1 48 7 41 1...

Page 15: ...TION UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER UPFLOW HORIZONTAL AND DOWNFLOW F2RC F2FC OR F2RC F2FP FAN COIL UNITS UPFLOW HORIZONTAL G2FD COIL ...

Page 16: ...e without notice Printed in U S A 036 21215 003 Rev B 1202 Copyright by York International Corp 2002 All rights reserved Supersedes 036 21215 003 Rev A 0602 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...