036-21315-001 Rev. A (0502)
Unitary Products Group
3
- = Not applicable
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL SENS.
1 PH 14 SEER AC WITH N-AH / G2FD
H1RE024S06
N1AHB0806
2,5,8,10
17
G2FD036S17
800
25.2
18.1
-
14.00
12.35
H1RE030S06
N1AHB1206
5,8,10,15,19
17
G2FD036S17
1000
28.8
20.7
-
13.10
11.80
H1RE036S06
N1AHB1206
5,8,10,15,19
17
G2FD036S17
1200
34.0
24.5
-
13.35
11.80
N1AHB1206
5,8,10,15,19
17
G2FD046S17
1200
35.0
25.6
-
14.00
12.20
N1AHD1406
5,8,10,15
24
G2FD048S24
1200
35.4
25.7
-
14.00
12.50
N1AHD1406
5,8,10,15
24
G2FD060S24
1200
36.0
26.1
-
14.20
12.80
H2RE042S06
N1AHC1606
5,8,10,15,20
21
G2FD042S21
1400
39.0
28.2
-
13.25
11.35
N1AHC1606
5,8,10,15,20
21
G2FD048S21
1400
39.5
28.9
-
13.50
11.60
N1AHD1406
5,8,10,15
24
G2FD060S24
1400
40.5
29.6
-
14.00
12.00
H2RE048S06
N1AHD2006
8,10,15,20,25,30
24
G2FD060S24
1600
46.5
33.9
-
13.85
11.80
N1AHD2006
8,10,15,20,25,30
24
G2FD061H24
1600
47.0
34.3
-
14.00
11.90
H2RE060S06
N1AHD2006
8,10,15,20,25,30
24
G2FD060S24
1900
53.5
37.1
-
13.50
12.00
N1AHD2006
8,10,15,20,25,30
24
G2FD061H24
2050
54.5
39.1
-
13.50
12.10
1 PH 14 SEER AC / N1VS - VARIABLE SPEED
H1RE024S06
N1VSB12
10,15,18
17
G2FD036S17
870
25.6
18.1
-
15.00
13.85
N1VSB12
10,15,18
17
G2FD046S17
870
26.2
18.9
-
15.50
14.15
H1RE030S06
N1VSB12
10,15,18
17
G2FD036S17
1000
29.4
20.7
-
14.50
12.95
N1VSB12
10,15,18
17
G2FD046S17
1070
30.0
21.6
-
15.35
13.60
H1RE036S06
N1VSB12
10,15,18
17
G2FD046S17
1250
35.2
25.6
-
14.00
12.40
N1VSC16
10,15,18
21
G2FD048S21
1285
36.0
25.7
-
15.00
13.60
H2RE042S06
N1VSC16
10,15,18
21
G2FD048S21
1420
40.5
28.9
-
14.50
12.50
N1VSC16
10,15,18
21
G2FD048S21
1420
40.5
28.9
-
14.50
12.50
N1VSD20
10,15,18,30
24
G2FD060S24
1420
41.5
29.6
-
15.50
13.20
H2RE048S06
N1VSC16
10,15,18
21
G2FD048S21
1590
46.0
33.2
-
14.30
12.20
N1VSD20
10,15,18,30
24
G2FD060S24
1600
47.0
33.9
-
14.65
12.40
H2RE060S06
N1VSD20
8,10,15,20,25,30
24
G2FD060S24
1780
53.5
36.3
-
13.75
12.35
N1VSD20
8,10,15,20,25,30
24
G2FD061H24
1780
54.5
37.0
-
14.00
12.60
1 PH 14 SEER AC / F2RP / RC / FP / FC / FV
4,5
H1RE024S06
F2RP/FP036
5,8,10,15,19
21
-
800
25.0
18.0
-
13.80
12.30
F2FP040
5,8,10,15
21
-
800
25.4
17.4
-
14.00
12.75
H1RE030S06
F2RP/FP036
5,8,10,15,19
21
-
1000
29.8
21.5
-
13.85
12.40
F2FP045
5,8,10,15
24
-
1000
30.6
21.5
-
14.00
12.70
H1RE036S06
F2RP/FP036
5,8,10,15,19
21
-
1200
34.4
24.8
-
13.50
12.10
F2RP/FP042
5,8,10,15
21
-
1200
34.4
24.8
-
13.30
11.90
F2FP045
5,8,10,15
24
-
1200
36.0
25.5
-
14.00
12.65
H2RE042S06
F2FP045
5,8,10,15
24
-
1400
40.5
29.8
-
14.00
12.00
F2FP048
5,8,10,15,20,25
24
-
1400
39.5
28.9
-
13.25
11.30
H2RE048S06
F2FP060
5,8,10,15,20,25
24
-
1600
46.0
33.4
-
13.00
11.25
F2FV060
8,10,15,20,25
24
-
1625
47.5
34.9
-
15.50
13.20
H2RE060S06
F2FP060
10,15,20,25
24
--
1900
53.0
36.7
-
13.00
11.60
F2FV060
10,15,20,25
24
--
1900
53.5
36.3
-
13.75
12.35
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.