036-21315-001 Rev. A (0502)

10

Unitary Products Group

Multipliers for determining the performance with other indoor sections.

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

H1RE036S06

INDOOR COIL MODEL NO.

G1UA048S21, 24

CONDENSER 

ENTERING AIR

TEMPERATURE

ID CFM

1000

1200

1400

ID DB

85

80

70

85

80

70

85

80

70

ID WB

72

67

57

72

67

57

72

67

57

75

T.C.

40.0

36.9

34.3

41.3

38.1

35.7

42.0

38.9

36.7

S.C.

25.4

24.4

23.4

27.6

26.3

25.5

29.6

27.9

27.2

K.W

1.98

1.96

1.94

1.99

1.97

1.95

2.00

1.98

1.96

85

T.C.

38.6

35.6

32.7

39.6

36.6

34.0

40.2

37.3

34.9

S.C.

24.8

23.8

22.8

27.0

25.8

24.9

29.1

27.6

26.6

K.W

2.21

2.18

2.17

2.22

2.19

2.18

2.23

2.20

2.19

95

T.C.

37.2

34.2

31.0

37.8

35.2

32.4

38.4

35.8

33.0

S.C.

24.2

23.3

22.3

26.4

25.3

24.2

28.5

27.2

25.9

K.W

2.44

2.41

2.40

2.45

2.42

2.41

2.46

2.42

2.42

105

T.C.

35.5

32.3

29.6

36.1

33.1

30.6

36.7

33.7

31.2

S.C.

23.5

22.6

21.7

25.6

24.6

23.5

27.6

26.5

25.3

K.W

2.75

2.72

2.72

2.75

2.73

2.72

2.76

2.73

2.73

115

T.C.

33.7

30.4

28.1

34.4

31.1

28.7

35.0

31.7

29.4

S.C.

22.8

21.8

21.1

24.7

23.9

22.8

26.8

25.8

24.6

K.W

3.06

3.04

3.03

3.06

3.04

3.02

3.07

3.04

3.03

125

T.C.

31.9

28.5

26.7

32.7

29.1

26.9

33.3

29.7

27.6

S.C.

22.2

21.1

20.5

23.9

23.1

22.1

25.9

25.1

24.0

K.W

3.37

3.36

3.34

3.37

3.35

3.32

3.38

3.35

3.33

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Air Handler

Coil

T.C.

S.C.

KW

N1AHB1206

G2FD036S17

0.97

0.97

1.01

N1AHB1206

G2FD046S17

0.99

1.01

1.00

N1VSB12

G2FD046S17

1.00

1.01

0.99

N1VSC16

G2FD048S21

1.02

1.02

0.92

N1AHD14

G2FD048S24

1.01

1.02

0.99

N1AHD14

G2FD060S24

1.02

1.03

0.98

F2FP045

1.02

1.01

0.99

F2RP/F2FP042

0.98

0.98

1.01

F2RP/F2FP036

0.98

0.98

0.99

G1FA048S21,24

1.00

1.00

1.00

GFD042S21

0.99

1.00

1.00

G2FD036S17

0.97

0.97

1.01

G2FD036S21

0.97

0.98

0.99

G2FD046S17

0.99

1.01

1.00 

G2FD048S21,24

1.00

1.02

0.99

G1HD048S

0.99

0.99

0.99

G1NA036S17L

0.94

0.92

1.02

G1NA042S24W

0.98

0.99

1.01

GNA048S21D

0.94

0.92

1.02 

G1UA048S21,24

1.00

1.00

1.00

Variable Speed 

Furnace

Coil

T.C.

S.C.

KW

P1DUB16V

G2FD036S17

0.98

0.97

0.95

P1DUC20V

G1FA048S21

1.03

1.00

0.89

P1DUC20V

G1UA048S21

1.03

1.00

0.89

P1DUC20V

G2FD036S21

0.98

0.98

0.93

P1DUC20V

G2FD048S21

1.02

1.02

0.90

P1XDB12V

G2FD036S17

0.99

0.97

0.97

P1XDD20V

G2FD048S24

1.03

1.02

0.97

P1XUB12V

G2FD036S17

0.98

0.97

0.95

Summary of Contents for H*RE024

Page 1: ...ing condi tions occur A liquid line filter drier further protects the compressor DURABLE FINISH The cabinet is made of pre painted steel The pre treated galvanized steel provides a better paint to ste...

Page 2: ...ne OD 3 8 3 8 3 8 3 8 3 8 3 8 Vapor Line OD 7 8 7 8 7 8 1 1 8 1 1 8 1 1 8 Unit Charge Lbs Oz 4 8 0 9 14 9 6 14 0 14 3 15 13 Charge Per Foot oz 0 70 0 70 0 70 0 76 0 76 0 76 Operating Weight Lbs 209 22...

Page 3: ...1VSD20 10 15 18 30 24 G2FD060S24 1600 47 0 33 9 14 65 12 40 H2RE060S06 N1VSD20 8 10 15 20 25 30 24 G2FD060S24 1780 53 5 36 3 13 75 12 35 N1VSD20 8 10 15 20 25 30 24 G2FD061H24 1780 54 5 37 0 14 00 12...

Page 4: ...24 1000 30 2 21 8 14 00 12 50 H1RE036S06 1050 1350 21 24 G1FA048S21 24 1200 35 2 25 3 14 00 12 30 G1HD048 1200 34 8 25 0 13 75 12 30 17 G1NA036S17L 1200 33 0 23 4 13 00 11 30 24 G1NA042S24W 1200 34 6...

Page 5: ...7 14 00 12 65 H1RE036S06 P1DUB16V G2FD036S17 17 1200 34 4 24 5 14 00 12 70 P1DUC20V G1FA048S21 21 1200 36 2 25 3 15 50 14 15 P1DUC20V G1UA048S21 21 1200 36 2 25 3 15 50 14 15 P1DUC20V G2FD036S21 21 12...

Page 6: ...tomatic fan on cooling or cooling and heating 6ET07700324 One Stage Heat One Stage Cool electronic programmable 5 day 2 day manual changeover SOUND RATINGS Includes Blanket COOLING PERFORMANCE MODEL S...

Page 7: ...S WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL NOTE ALL OUTDOOR WIRING MUST BE WEATHERPROOF ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC AND OR LOCAL CODES POWER WIRING 208 230 1 60...

Page 8: ...07 2 25 2 21 2 17 2 14 2 28 2 24 2 21 2 17 115 T C 23 6 21 7 20 0 18 6 23 8 22 0 20 5 18 9 24 0 22 3 20 7 19 1 S C 15 9 15 8 15 8 14 6 17 1 16 9 16 1 14 9 17 9 17 6 16 3 15 1 K W 2 36 2 31 2 26 2 21...

Page 9: ...19 2 16 2 10 2 23 2 20 2 17 2 12 2 24 2 21 2 18 2 13 115 T C 28 6 26 0 24 0 21 2 29 0 26 5 24 4 22 1 29 3 26 8 24 7 22 5 S C 18 8 18 7 17 9 18 7 20 4 20 4 19 4 20 3 21 5 21 4 20 5 20 8 K W 2 37 2 32...

Page 10: ...23 9 22 8 26 8 25 8 24 6 K W 3 06 3 04 3 03 3 06 3 04 3 02 3 07 3 04 3 03 125 T C 31 9 28 5 26 7 32 7 29 1 26 9 33 3 29 7 27 6 S C 22 2 21 1 20 5 23 9 23 1 22 1 25 9 25 1 24 0 K W 3 37 3 36 3 34 3 37...

Page 11: ...2 34 5 31 7 29 3 37 6 34 8 32 1 30 0 37 8 35 0 32 3 30 3 S C 25 1 25 2 25 5 25 6 26 7 26 7 27 1 26 6 27 7 27 7 27 9 26 9 K W 4 26 4 23 4 21 4 19 4 32 4 29 4 27 4 26 4 36 4 34 4 31 4 30 125 T C 34 7 3...

Page 12: ...3 78 3 75 3 74 3 79 3 76 3 75 3 79 3 77 3 75 115 T C 44 1 41 1 37 8 44 9 41 6 38 4 45 6 42 2 39 1 S C 30 8 29 8 28 1 33 1 31 9 30 2 35 4 34 1 32 3 K W 4 18 4 16 4 15 4 19 4 16 4 15 4 21 4 16 4 15 125...

Page 13: ...47 6 56 5 52 5 48 0 57 1 52 9 48 4 S C 40 0 38 3 35 7 41 4 39 6 37 1 42 8 40 8 38 4 K W 4 51 4 47 4 43 4 52 4 48 4 44 4 53 4 48 4 45 115 T C 52 8 49 0 45 3 53 5 49 5 45 2 54 3 50 0 45 2 S C 38 9 37 0...

Page 14: ...N UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APP...

Page 15: ...036 21315 001 Rev A 0502 Unitary Products Group 15 NOTES...

Page 16: ...o change without notice Printed in U S A 036 21315 001 Rev A 0502 Copyright by York International Corp 2002 All rights reserved Supersedes 550 50 TG1Y 600 Unitary 5005 Norman Product York OK Group Dri...