background image

036-21137-003 Rev. A (1102)

                            

2

Unitary Products Group

PHYSICAL AND ELECTRICAL DATA - 1 Phase

MODEL

H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H3RC060S06

Unit Supply Voltage

208/230 – 1 – 60

Normal Voltage Range 

1

187 to 252

Minimum Circuit Ampacity

10.1

14.1

16.5

19.7

26.2

28.5

37.4

Max. Overcurrent Device Amps 

2

15

25

25

30

45

50

60

Compressor Type

3

Recip

Inertia

Recip

Recip

Scroll

B

Recip

Scroll

C

Compressor Amps

Rated Load

7.7

10.9

12.8

14.7

19.9

21.8

28.8

Locked Rotor

48

60

68

82

115

105

169

Crankcase Heater

No

No

No

Yes

No

No

No

Fan Motor Amps

Rated Load

0.5

0.5

0.5

1.3

1.3

1.3

1.3

Fan Diameter Inches

18

18

22

22

22

22

22

Fan Motor

Rated HP

1/12

1/12

1/15

1/4

1/4

1/4

1/4

Nominal RPM

1,100

1,100

850

850

850

850

850

Nominal CFM

2,000

2,000

2,300

3,300

3,300

3,300

3,400

Coil

Face Area Sq. Ft.

12.58

12.58

15.72

15.72

17.03

19.65

23.58

Rows  Deep

1

1

1

1

1

1

1

Fin / Inches

18

18

18

18

18

18

18

Liquid Line OD

3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line OD

3/4

3/4

3/4

3/4

7/8

7/8

7/8

Unit Charge (Lbs. - Oz.) 

4

4 - 9

4 - 7

5 - 8

5 - 3

6 - 13

7 - 7

9 - 0

Charge Per Foot, Oz.

0.68

0.68

0.68

0.68

0.70

0.70

0.70

1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-

tract the amount of refrigerant, using the difference in length multiplied by the per foot value.

PHYSICAL AND ELECTRICAL DATA - 3 Phase

MODEL

H1RC036S25 H1RC048S25 H1RC060S25

H1RC036S46 H1RC048S46 H1RC060S46

Unit Supply Voltage

208/230 – 3 – 60

460 - 3 - 60

Normal Voltage Range 

1

187  to 252

432 to 504

Minimum Circuit Ampacity

13.3

18.9

22.9

7.6

9.6

12.0

Max. Overcurrent Device Amps 

2

20

30

40

15

15

20

Compressor Type

Inertia

Inertia

Scroll

Inertia

Inertia

Scroll

Compressor Amps

Rated Load

9.6

14.1

17.3

5.4

7.0

9.0

Locked Rotor

78.0

130.0

123.0

40.0

64.0

62.0

Crankcase Heater

No

No

No

No

No

No

Fan Motor Amps

Rated Load

1.3

1.3

1.3

0.8

0.8

0.8

Fan Diameter Inches

22

22

22

22

22

22

Fan Motor

Rated HP

1/4

1/4

1/4

1/4

1/4

1/4

Nominal RPM

850

850

850

850

850

850

Nominal CFM

3,300

3,300

3,400

3,300

3,300

3,400

Coil

Face Area Sq. Ft.

15.72

17.03

23.58

15.72

17.03

23.58

Rows Deep

1

1

1

1

1

1

Fin / Inches

18

18

18

18

18

18

Liquid Line OD

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line OD

3/4

7/8

1-1/8

3/4

7/8

1-1/8

Unit Charge (Lbs. - Oz.) 

3

6 - 2

7 - 10

9 - 3

6 - 2

7 - 10

9 - 3

Charge Per Foot, Oz.

0.68

0.70

0.76

0.68

0.70

0.76

Operating Weight Lbs.

157

184

198

157

184

198

1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-

tract the amount of refrigerant, using the difference in length multiplied by the per foot value.

Summary of Contents for H*RC018 THRU 060

Page 1: ...is is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating condi tions occur A liquid line filter dr...

Page 2: ...ed indoor coil and 15 feet of refrigerant tubing For tubing lengths other than 15 feet add or sub tract the amount of refrigerant using the difference in length multiplied by the per foot value PHYSIC...

Page 3: ...2 12 702 0 703 0 G2FD048S H 21 24 84 73 16 78 10 87 11 702 16 702 10 703 11 G2FD060S H 24 90 87 15 703 15 703 20 G2FD061H24 90 87 19 703 19 703 25 G1HD024 59 53 5 59 4 701 5 701 4 G1HD036 69 59 13 63...

Page 4: ...F048SOF 78 78 21 87 6 702 21 703 6 G1NF060SOF 87 87 18 703 18 703 0 F2RP024N06 61 53 4 59 4 701 4 701 4 F2RP030N06 65 59 6 63 4 701 6 701 4 F2RP036N06 75 63 4 73 8 701 4 702 8 F2RP042N06 78 73 13 78 0...

Page 5: ...changed verify the evaporator nameplate has been marked with the correct orifice size Additional R 22 Charge Orifice Size for Various Matched Systems 3 Phase Outdoor Unit H1RC036S H1RC048S H1RC060S U...

Page 6: ...18 21 G2FD048 S H 21 1400 43 0 30 6 13 00 11 55 N1VSC16 10 15 18 21 G2FD048 S H 21 1590 47 0 30 6 12 80 11 40 H2RC048S06 N1VSC16 10 15 18 21 G2FD048 S H 21 1590 47 0 34 9 12 80 12 80 11 40 N1VSD20 10...

Page 7: ...11 00 17 G1FA048S17 1000 31 2 22 3 12 50 12 50 11 45 21 G1FA048S21 1000 31 2 22 3 12 50 12 50 11 35 G1HD036 1000 30 8 21 9 12 75 12 75 11 25 17 G1NA030S17K 1000 30 2 21 4 12 00 12 00 11 05 21 G1NA030S...

Page 8: ...1FA048S21 1575 46 5 34 9 12 00 12 00 11 00 21 24 G1FA060S21 24 1575 48 0 36 0 12 50 12 50 11 10 G1HD048 1575 46 0 34 5 12 00 12 00 10 80 G1HD060 1575 47 5 35 6 12 40 12 40 11 05 21 G1NA048S21D 1575 46...

Page 9: ...0 11 15 P1DUB16V G2FD036 S H 17 17 1200 34 4 24 2 12 25 11 40 P1DUC20V G1FA036S21 21 1200 33 6 23 6 12 00 11 30 P1DUC20V G2FD036 S H 21 21 1200 34 8 24 4 13 00 11 60 P1XDB12V G2FD036 S H 17 17 1130 34...

Page 10: ...s for specific model number 2 TXV Use 1TV700 Series Kit 3 Variable speed furnaces have B O D Blower on Delay standard COOLING PERFORMANCE MODEL SUCT T P COMPR AIR TEMP ON CONDENSER MODEL SUCT T P COMP...

Page 11: ...Stage only manual mechanical thermostat Add sub base for 1H 1C 1H 1C manual change over electronic non programmable thermostat 1H 1C auto manual changeover electronic programmable deluxe 7 day thermo...

Page 12: ...30 1 60 CONTACTOR TERMINALS COIL GND LUG C Y R G W Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA WIRE NEC CLASS 2 FURNACE OR AIR HANDLER TERMINAL BLOCK ROOM T...

Page 13: ...14 2 13 6 KW 1 47 1 45 1 43 1 48 1 47 1 45 1 49 1 48 1 46 105 T C 18 1 16 3 14 2 18 7 17 1 15 0 19 4 17 8 15 8 S C 11 3 10 6 9 7 13 0 12 2 11 3 14 7 13 8 12 9 KW 1 58 1 55 1 52 1 59 1 57 2 53 1 61 1 5...

Page 14: ...6 2 07 2 02 1 98 2 09 2 04 2 00 115 T C 21 3 18 6 16 2 22 0 19 5 17 0 22 8 20 5 17 7 S C 14 0 12 9 12 0 16 3 15 3 14 2 18 6 17 8 16 4 KW 2 19 2 13 2 08 2 22 2 16 2 10 2 25 2 18 2 12 125 T C 19 8 16 4...

Page 15: ...3 19 5 KW 2 70 2 61 2 55 2 74 2 64 2 57 2 77 2 68 2 59 125 T C 24 0 20 4 17 0 26 7 21 7 16 8 29 4 23 2 16 7 S C 17 1 15 6 14 1 20 2 17 9 16 0 23 3 20 5 17 8 KW 2 88 2 76 2 70 2 94 2 79 2 70 3 00 2 84...

Page 16: ...2 22 6 28 4 25 5 22 9 S C 21 4 20 0 19 0 23 8 22 3 21 1 26 2 24 6 23 2 KW 3 36 3 29 3 19 3 38 3 31 3 23 3 39 3 33 3 26 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 10...

Page 17: ...33 4 30 8 27 2 33 6 31 3 27 7 S C 23 7 22 5 20 7 24 5 23 6 21 9 25 4 24 6 23 0 KW 4 01 3 88 3 75 4 02 3 91 3 77 4 03 3 93 3 78 125 T C 31 0 27 6 23 5 31 1 28 1 24 1 31 3 28 5 24 4 S C 23 1 21 3 19 6 2...

Page 18: ...37 4 43 9 41 5 38 1 44 2 42 0 38 9 S C 28 4 27 6 25 9 30 0 29 7 28 2 31 6 31 8 30 5 KW 3 39 3 38 3 36 3 39 3 38 3 36 3 40 3 39 3 37 115 T C 41 2 38 1 34 1 41 6 38 7 34 9 42 0 39 3 35 7 S C 27 8 26 7...

Page 19: ...2 6 41 9 37 2 33 1 S C 30 5 28 3 26 3 33 1 30 5 28 4 35 7 32 8 30 5 KW 4 28 4 15 4 02 4 32 4 17 4 05 4 35 4 19 4 08 125 T C 36 3 31 3 28 5 36 9 31 9 28 8 37 6 32 5 29 1 S C 29 2 26 8 24 8 31 8 28 9 26...

Page 20: ...6 2 42 5 39 3 36 2 S C 30 5 30 6 29 5 30 9 32 6 32 8 31 5 32 8 34 1 34 2 32 7 34 5 KW 4 67 4 45 4 25 4 03 4 72 4 49 4 30 4 09 4 74 7 53 4 34 4 18 115 T C 41 8 38 3 35 3 31 7 42 3 38 8 35 8 33 0 42 5 3...

Page 21: ...38 8 43 1 42 6 41 6 KW 5 24 5 10 5 06 5 25 5 11 5 07 5 26 5 12 5 08 105 T C 58 1 54 6 50 0 58 9 55 7 51 3 59 7 56 8 52 7 S C 36 9 36 0 34 4 39 8 39 0 37 3 42 7 41 9 40 2 KW 5 86 5 72 5 63 5 87 5 74 5...

Page 22: ...LOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APPLICAT...

Page 23: ...036 21137 003 Rev A 1102 Unitary Products Group 23 NOTES...

Page 24: ...nge without notice Printed in U S A 036 21137 003 Rev A 1102 Copyright by York International Corp 2002 All rights reserved Supersedes 036 21137 002 Rev C 0602 Unitary 5005 Norman Products York OK Grou...

Reviews: