036-21137-003 Rev. A (1102)
10
Unitary Products Group
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.
a. Increase capacity 1% for each 2° increase in sub-cooling.
b. Decrease capacity 1% for each 2° decrease in sub-cooling.
3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°. Maximum recommended
condensing temperature is 140°F.
H2RC048S06
P1DUC20V
G1FA048S21
21
1610
46.5
34.9
-
12.10
11.15
P1DUC20V
G2FD048(S,H)21
21
1610
46.5
34.9
-
12.25
11.05
P1XDD20V
G2FD048(S,H)24
24
1610
47.0
35.4
-
12.40
11.00
P1XUC16V
G1FA048S21
21
1480
46.0
34.4
-
12.10
10.90
P1XUC16V
G2FD048(S,H)21
21
1480
46.0
34.4
-
12.30
10.80
P1XUC20V
G1FA048S21
21
1590
46.5
34.9
-
12.10
11.10
P1XUC20V
G2FD048(S,H)21
21
1590
46.5
34.9
-
12.25
11.00
P1XUD20V
G1FA060S24
24
1560
48.5
36.5
-
13.00
11.45
P1XUD20V
G2FD048(S,H)24
24
1560
47.0
35.4
-
12.50
11.20
P1XUD20V
G2FD060(S,H)24
24
1560
48.5
36.5
-
13.00
11.45
H1RC048S(25,46)
P1DUC20V
G1FA048S21
21
1610
45.5
33.7
-
12.20
11.20
P1DUC20V
G2FD048(S,H)21
21
1610
45.5
33.7
-
12.25
11.40
P1XUC16V
G1FA048S21
21
1480
45.0
33.2
-
12.20
10.95
P1XUC16V
G2FD048(S,H)21
21
1480
45.0
33.2
-
12.30
11.10
P1XUC20V
G1FA048S21
21
1590
45.5
33.7
-
12.10
11.15
P1XUC20V
G2FD048(S,H)21
21
1590
45.5
33.7
-
12.25
11.35
P1XUD20V
G1FA060S24
24
1620
47.0
34.8
-
12.75
11.65
P1XUD20V
G2FD048(S,H)24
24
1620
45.5
33.7
-
12.25
11.30
P1XUD20V
G2FD060(S,H)24
24
1620
47.0
34.8
-
12.75
11.65
H3RC060S06
H1RC060S(25,46)
P1XDD20V
G2FD060(S,H)24
24
1805
57.0
42.6
-
11.50
10.00
P1XUC20V
G1FA060S21
21
1620
57.0
42.1
-
12.10
10.20
P1XUD20V
G1FA060S24
24
1620
57.0
42.1
-
12.10
10.40
P1XUD20V
G2FD060(S,H)24
24
1620
57.0
42.1
-
12.10
10.40
P1XUD20V
G2FD061
H
24
24
1800
58.0
43.2
-
12.10
10.55
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. TXV = Use 1TV700 Series Kit.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING PERFORMANCE
MODEL
SUCT. T/P
@ COMPR.
AIR TEMP ON CONDENSER
MODEL
SUCT. T/P
@ COMPR.
AIR TEMP ON CONDENSER
75
°
F
95
°
F
115
°
F
75
°
F
95
°
F
115
°
F
TEMP. PSIG MBH KW MBH KW MBH KW
TEMP. PSIG MBH KW MBH KW MBH KW
H2RC018S06
35
61.5
17.19 1.44 13.89 1.59
11.63
1.70
H2RC042S06
35
61.5
35.94 3.12 31.92 3.76 27.86 4.54
40
68.5
18.77 1.45 15.80 1.63 13.53 1.77
40
68.5
39.29 3.15
35.11
3.77 30.80 4.55
45
76.0
20.48 1.47 17.70 1.66 15.04 1.83
45
76.0
42.48 3.21 38.17 3.84 33.70 4.63
50
84.0
21.99 1.48 19.60 1.70 16.81 1.89
50
84.0
45.62 3.23 41.40 3.92 36.56 4.39
H2RC024S06
35
61.5
20.81 1.81 16.82 2.00 14.07 2.14
H2RC048S06
35
61.5
40.62 3.39 36.09 4.08 31.50 4.91
40
68.5
22.73 1.83 19.13 2.05 16.37 2.23
40
68.5
44.42 3.41 39.69 4.09 34.83 4.94
45
76.0
24.80 1.85 21.43 2.09 18.20 2.31
45
76.0
48.02 3.47 43.16 4.16 38.10 5.02
50
84.0
26.63 1.86 23.73 2.14 20.36 2.37
50
84.0
51.58 3.50 46.81 4.25 41.33 4.76
H2RC030S06
35
61.5
26.48 2.34 21.42 2.59 17.91 2.77
H1RC048S(25,46)
35
61.5
39.75 3.32 35.31 3.99 30.82 4.81
40
68.5
28.94 2.36 24.34 2.65 20.84 2.92
40
68.5
43.46 3.34 38.84 4.00 34.08 4.83
45
76.0
31.56 2.39 27.07 2.71 23.17 2.96
45
76.0
46.99 3.40 42.23 4.07 37.28 4.91
50
84.0
33.89 2.40 30.20 2.77 25.92 3.07
50
84.0
50.47 3.43 45.80 4.16 40.44 4.66
H2RC036S06
35
61.5
29.38 2.76 23.75 3.06 19.87 3.26
H3RC060S06
H1RC060S(25,46)
35
61.5
50.26 4.42 44.64 5.32 38.97 6.42
40
68.5
32.09 2.78 27.00 3.13 23.12 3.40
40
68.5
54.95 4.46 49.10 5.33 43.08 6.44
45
76.0
35.01 2.81 30.25 3.19 25.70 3.51
45
76.0
59.41 4.54 53.38 5.43 47.13 6.55
50
84.0
37.59 2.83 33.50 3.26 28.74 3.62
50
84.0
63.81 4.58 57.90 5.55 51.13 6.22
H1RC036S(25,46)
35
61.5
29.20 2.70 23.61 2.99 19.75 3.19
40
68.5
31.90 2.72 26.84 3.06 22.98 3.32
45
76.0
34.80 2.75 30.07 3.12 25.54 3.43
50
84.0
37.36 2.77 33.30 3.19 28.57 3.54
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
2
EER
TOTAL
SENS.