279747-YTG-A-0407
Unitary Products Group
3
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
RATINGS & PHYSICAL / ELECTRICAL DATA
Models
Input
Output
Nominal
Airflow
Cabinet
Width
Total Unit
Amps
AFUE
Air Temp.
Rise
MBH
MBH
CFM
In.
°F
(G,L)Y8S040A12DH11
40
32
1200
14-1/2
9.0
80.0
20-50
(G,L)Y8S060A12DH11
60
48
1200
14-1/2
9.0
80.0
25-55
(G,L)Y8S080A12DH11
80
64
1200
14-1/2
9.0
80.0
35-65
(G,L)Y8S080B16DH11
80
64
1600
17-1/2
12.0
80.0
25-55
(G,L)Y8S080C16DH11
80
64
1600
21
12.0
80.0
25-55
(G,L)Y8S100B12DH11
100
80
1200
17-1/2
12.0
80.0
40-70
(G,L)Y8S100C16DH11
100
80
1600
21
12.0
80.0
25-55
(G,L)Y8S100C20DH11
100
80
2000
21
14.0
80.0
25-55
(G,L)Y8S115C16DH11
115
92
1600
21
12.0
80.0
35-65
(G,L)Y8S115C20DH11
115
92
2000
21
14.0
80.0
30-60
(G,L)Y8S130D20DH11
130
104
2000
24-1/2
14.0
80.0
40-70
Models
Input
Max. Outlet
Air Temp
Blower
Blower
Size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
Operation
Weight
MBH
°F
Hp
Amps
In.
Lbs.
(G,L)Y8S040A12DH11
40
150
1/3
6.2
10 x 8
20
14
100
(G,L)Y8S060A12DH11
60
155
1/3
6.2
10 x 8
20
14
110
(G,L)Y8S080A12DH11
80
165
1/3
6.2
10 x 8
20
14
120
(G,L)Y8S080B16DH11
80
160
3/4
11.0
11 x 10
20
14
130
(G,L)Y8S080C16DH11
80
160
3/4
11.0
10 x 10
20
14
130
(G,L)Y8S100B12DH11
100
170
1/2
7.0
10 x 8
20
14
125
(G,L)Y8S100C16DH11
100
155
3/4
11.0
11 X 10
20
14
140
(G,L)Y8S100C20DH11
100
155
1
12.2
11 x 11
20
12
140
(G,L)Y8S115C16DH11
115
165
3/4
11.0
11 x 10
20
14
150
(G,L)Y8S115C20DH11
115
160
1
12.2
11 x 11
20
12
150
(G,L)Y8S130D20DH11
130
170
1
12.2
11 x 11
20
12
160