York GY8S-DH Technical Manual Download Page 2

279747-YTG-A-0407

2

Unitary Products Group

FRONT

LEFT SIDE

RIGHT SIDE

FRONT

FRONT

BOTTOM IMAGE

TOP IMAGE

A

B

40

3/4

20

31-1/8

5-3/4

2-1/2

28-1/2

1-1/8

7-3/8

A

C

20

1-1/4

T’STAT WIRING

7/8” K.O.

GAS INLET

1-1/4” X 2-1/2”

ALT. GAS INLET

1-1/4” X 2-1/2”

(VENT CONNECTION)

5

1-7/8

20

B

D

3-3/4

4” Diameter

4” Diameter

CABINET AND DUCT DIMENSIONS

Models

CFM

Cabinet

Size

Cabinet Dimension

A

B

C

D

(G,L)Y8S040A12DH11

1200

A

14 1/2

13 1/4

12

10 3/8

(G,L)Y8S060A12DH11

1200

A

14 1/2

13 1/4

12

10 3/8

(G,L)Y8S080A12DH11

1200

A

14 1/2

13 1/4

12

10 3/8

(G,L)Y8S080B16DH11

1600

B

17 1/2

16 1/4

15

11 3/4

(G,L)Y8S080C16DH11

1600

C

21

19 3/4

18-1/2

13 1/2

(G,L)Y8S100B12DH11

1200

B

17 1/2

16 1/4

15

11 3/4

(G,L)Y8S100C16DH11

1600

C

2

19 3/4

18-1/2

13 1/2

(G,L)Y8S100C20DH11

2000

C

21

19 3/4

18-1/2

13 1/2

(G,L)Y8S115C16DH11

1600

C

21

19 3/4

18-1/2

13 1/2

(G,L)Y8S115C20DH11

2000

C

21

19 3/4

18-1/2

13 1/2

(G,L)Y8S130D20DH11

2000

D

24 1/2

23 1/4

22

15 1/4

Summary of Contents for GY8S-DH

Page 1: ...and may be common vented with another gas appliance as allowed by the National Fuel Gas Code ANSI Z223 1 latest edition WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger w...

Page 2: ...net Dimension A B C D G L Y8S040A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S060A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S080A12DH11 1200 A 14 1 2 13 1 4 12 10 3 8 G L Y8S080B16DH11 1600 B 17 1 2...

Page 3: ...1 2 12 0 80 0 40 70 G L Y8S100C16DH11 100 80 1600 21 12 0 80 0 25 55 G L Y8S100C20DH11 100 80 2000 21 14 0 80 0 25 55 G L Y8S115C16DH11 115 92 1600 21 12 0 80 0 35 65 G L Y8S115C20DH11 115 92 2000 21...

Page 4: ...1491 1412 1311 1192 1049 908 750 Low 1561 1493 1430 1373 1304 1199 1089 967 816 699 G L Y8S100B12DH11 High 1710 1650 1580 1510 1420 1330 1260 1160 1090 930 Medium High 1480 1440 1380 1330 1270 1180 10...

Page 5: ...em Static Pressure ESP without the filter 4 Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to deter...

Page 6: ...ion of compatible thermosets are available to provide optimum performance and features for any installation 1H 1C manual change over electronic non programmable thermostat 1H 1C auto manual changeover...

Page 7: ...eat W First Stage Heat W Single Stage Heat HM1 Humidistat Thermostat Installer Setup Number 1 System Type must be set to 0 Selection of GAS ELEC switch on thermostat not necessary Thermostat Installer...

Page 8: ...change without notice Printed in U S A 279747 YTG A 0407 Copyright by York International Corp 2007 All rights reserved Supersedes 246794 YTG C 0706 Unitary 5005 Norman Products York OK Group Drive 73...