![background image](http://html1.mh-extra.com/html/york/ghgd18/ghgd18_technical-manual_3964565005.webp)
571921-UTG-A-0410
Johnson Controls Unitary Products
5
— = Not applicable.
13 SEER HP WITH AHP / SHP / AHX / F*FP
GHGD18S41S3
AHP18 17
–
600
18.0
14.0
13.00
11.00
AHX18 17
–
600
18.0
14.0
14.50
12.00
F4FP024 17
–
600
18.0
14.0
13.00
11.00
F6FP018 17
–
600
18.0
14.0
14.50
12.00
F6FP024 17
–
610
18.0
14.0
14.50
12.00
GHGD24S41S4
AHP30
17
–
800
23.8
17.1
13.00
11.00
F4FP040
21
–
800
23.8
17.1
13.00
11.00
AHX30
17
–
820
24.0
17.5
14.00
12.00
AHX36
21
–
820
24.0
17.5
14.00
12.00
F6FP030
17
–
850
24.0
17.6
14.00
12.00
F6FP036
21
–
855
24.0
17.6
14.00
12.00
GHGD30S41S4
AHP30
17
–
1000
30.0
22.2
13.00
11.00
AHP36
21
–
1000
30.0
22.2
13.00
11.00
AHX30
17
–
1025
30.0
22.6
14.50
12.00
AHX36
21
–
1005
30.0
22.4
14.50
12.00
F4FP040
21
–
1000
29.8
21.8
13.00
11.00
F6FP030
17
–
1035
30.0
22.0
14.00
11.50
F6FP036
21
–
980
30.0
22.0
14.50
12.00
GHGD36S41S4
AHP36
21
–
1200
36.0
26.4
13.00
11.00
AHX36
21
–
1225
36.0
26.8
14.50
12.00
F6FP042
24
–
1290
36.0
27.6
14.50
12.00
F5FP048
24
–
1235
36.0
27.2
14.50
12.00
F4FP045
24
–
1200
36.0
26.8
13.00
11.00
AHX42
21
–
1190
36.0
26.8
14.50
12.00
AHP42
21
–
1255
36.0
27.2
13.00
11.00
GHGD42S41S4
AHX42
21
–
1395
40.5
32.4
14.00
12.00
F6FP042
24
–
1455
40.5
32.8
13.50
11.50
AHP60
24
–
1400
42.0
32.4
14.00
12.00
AHP48
24
–
1370
41.0
31.0
13.00
11.00
AHX48
24
–
1445
42.0
33.0
14.50
12.00
F4FP045
24
–
1400
41.0
31.8
13.00
11.00
F5FP048
24
–
1455
41.5
32.6
14.00
12.00
F6FP048
24
–
1380
42.0
32.4
14.50
12.00
F5FP060
24
–
1485
42.0
33.2
14.00
12.00
GHGD48S41S4
AHP48
24
–
1685
45.0
34.6
13.00
11.00
AHP60
24
–
1600
44.5
34.0
14.50
12.00
AHX48
24
–
1660
45.5
35.0
14.50
12.00
AHX60
24
–
1570
45.5
34.4
14.50
12.00
F5FP060
24
–
1665
44.5
34.2
14.50
12.00
F6FP048
24
–
1625
45.0
34.4
14.50
12.00
F6FP060
24
–
1570
45.5
34.4
14.50
12.00
GHGD60S41S4
AHX60
24
–
1830
55.0
40.5
14.00
11.50
F6FP060
24
–
1875
56.0
41.5
14.00
12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.