571921-UTG-A-0410
26
Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. GHGD60S41S4
INDOOR COIL MODEL NO.
AHX60
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
1630
1830
2030
ID
DB
(°F)
80 80
75
80
80
80 80 75
80
80 80 80
75 80 80
ID
WB
(°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C.
54.6
57.9
58.1
63.9
69.9
56.8
59.2
59.2
65.2
71.2
58.9
60.5
60.3
66.5
72.6
S.C.
54.4
49.3
42.2
42.0
34.7
56.5
52.5
44.2
43.9
35.7
58.6
55.7
46.2
45.9
36.8
KW
3.2
3.2
3.3
3.3
3.4
3.3
3.3
3.3
3.4
3.4
3.4
3.4
3.4
3.5
3.5
75
T.C.
52.6
55.0
55.3
60.7
66.5
54.5
56.1
56.2
61.9
67.6
56.4
57.2
57.1
63.1
68.8
S.C.
52.3
48.2
40.9
40.6
33.1
54.2
51.0
42.9
42.6
34.2
56.1
53.9
44.9
44.6
35.2
KW
3.6
3.6
3.6
3.7
3.7
3.7
3.7
3.7
3.8
3.8
3.8
3.8
3.8
3.9
3.9
85
T.C.
50.5
52.2
52.4
57.5
63.1
52.2
53.0
53.2
58.6
64.0
53.8
53.9
53.9
59.7
65.0
S.C.
50.3
47.0
39.7
39.3
31.6
51.9
49.6
41.7
41.3
32.7
53.6
52.1
43.6
43.3
33.7
KW
4.0
4.0
4.0
4.1
4.1
4.1
4.1
4.1
4.2
4.2
4.2
4.2
4.2
4.2
4.3
95
T.C.
48.5
49.3
49.5
54.3
59.7
49.9
49.9
50.2
55.3
60.4
51.3
50.5
50.8
56.3
61.2
S.C.
48.2
45.9
38.5
38.0
30.1
49.6
48.1
40.4
40.0
31.1
51.0
50.3
42.3
42.0
32.2
KW
4.4
4.4
4.4
4.5
4.5
4.5
4.5
4.5
4.5
4.6
4.6
4.6
4.6
4.6
4.7
105
T.C.
45.8
45.9
46.0
50.6
55.7
47.1
47.0
46.5
51.4
56.4
48.5
48.1
47.1
52.1
57.0
S.C.
45.6
44.1
37.0
36.5
28.6
46.9
45.9
38.9
38.5
29.6
48.2
47.8
40.9
40.4
30.7
KW
4.9
4.9
4.9
4.9
5.0
5.0
5.0
5.0
5.0
5.1
5.1
5.1
5.1
5.1
5.2
115
T.C.
43.2
42.5
42.4
46.9
51.7
44.4
44.0
42.9
47.4
52.3
45.7
45.6
43.4
48.0
52.9
S.C.
43.0
42.3
35.5
35.1
27.0
44.2
43.8
37.4
37.0
28.1
45.5
45.4
39.4
38.9
29.2
KW
5.4
5.4
5.4
5.4
5.5
5.5
5.5
5.4
5.5
5.6
5.6
5.5
5.5
5.6
5.6
125
T.C.
40.5
39.1
38.8
43.1
47.7
41.7
41.1
39.3
43.5
48.2
42.9
43.1
39.8
43.8
48.7
S.C.
40.3
39.1
34.0
33.6
25.5
41.5
41.1
36.0
35.4
26.6
42.7
42.9
38.0
37.3
27.7
KW
5.9
5.8
5.8
5.9
6.0
5.9
5.9
5.9
6.0
6.0
6.0
6.0
6.0
6.1
6.1
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handlers
Coils
T.C.
S.C.
KW
–
FC/MC62
1.00
0.99
1.08
–
FC64
1.02
1.02
1.10
AHX60
–
1.00
1.00
1.03
F6FP060
–
1.02
1.02
1.01
MV20D
FC/MC62D
1.01
1.00
1.04
MV20D
FC64D
1.02
1.02
1.01
MA20D
FC/MC62D
1.00
0.99
1.08
MA20D
FC64D
1.02
1.02
1.10
Furnaces
Coils
T.C.
S.C.
KW
T*(8,L)X*C20
FC/MC62D
1.00
0.98
0.99
T*9X*C20
FC/MC62D
1.00
0.95
0.99
T*9X*D20
FC/MC62D
1.00
0.96
0.99
T*(8,L)X*C20
FC64D
1.02
1.00
1.01
T*9X*C20
FC64D
1.02
0.98
1.01
T*9X*D20
FC64D
1.02
0.99
1.01
(T*(8,L)C/T*8V)*C20
FC/MC62D
0.99
0.95
0.98
(T*9C/T*9V)*C20
FC/MC62D
0.99
0.95
1.02
(T*9C/T*9V)*D20
FC/MC62D
0.99
0.95
1.02
(T*(8,L)C/T*8V)*C20
FC64D
1.01
0.99
1.00
(T*9C/T*9V)*C20
FC64D
1.01
0.99
1.04
(T*9C/T*9V)*D20
FC64D
1.01
0.98
1.04