567173-XTG-A-0310

Johnson Controls Unitary Products

3

SOUND POWER RATINGS

* Rated in accordance with ARI 270-95 Standards.

COOLING CAPACITY (R-22) 

 With Air Handler Coils

Unit

Model

Air Handler

Cooling

Model

W

Rated

CFM

Net MBH

KW

Total

Sensible

GCGA & FRP (Single Phase)

GCGA36S23S3

FXRP036H06

21-1/2

1200

34.9

24.7

3.90

GCGA48S23S3

FXRP048H06

24

1600

45.1

32.5

5.04

GCGA60S23S3

FXRP060H06

24

2000

55.0

39.5

7.14

GCGA76S23S3

K4EU090A33

52

2800

76.2

56.7

8.02

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.

COOLING CAPACITY (R-407C) 

 With Air Handler Coils

Unit

Model

Air Handler

Cooling

Model

W

Rated

CFM

Net MBH

KW

Total

Sensible

GCGA & FRP (Single Phase)

GCGA36S23S3

FXRP036H06

21-1/2

1200

33.2

23.7

3.84

GCGA48S23S3

FXRP048H06

24

1600

44.8

32.6

5.18

GCGA60S23S3

FXRP060H06

24

2000

52.4

37.5

7.13

GCGA76S23S3

K4EU090A33

52

2800

72.5

54.8

8.10

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.

UNIT MODEL

(dBA)*

36

78.0

48

80.0

60

82.0

76

84.0

Summary of Contents for GCGA36 THRU 76

Page 1: ...ier further protects the compressor Durable Finish The cabinet is made of pre painted steel The pre treated galvanized steel provides a better paint to steel bond which resists corrosion and rust cree...

Page 2: ...Rows Deep 1 1 1 1 Fin Inches 18 18 18 18 Liquid Line Set OD Field Installed 3 8 3 8 3 8 1 2 Vapor Line Set OD Field Installed 3 4 7 8 7 8 1 1 8 R 22 Indoor Orifice 0 071 0 079 0 090 TXV R 22 Unit Cha...

Page 3: ...in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt hours during the same period COOLING CAPACITY R 407C With Air Handler Coils Unit Model Air Ha...

Page 4: ...6 9 03 40 68 6 80 6 6 19 76 9 6 61 73 2 7 11 69 3 7 66 65 2 8 22 60 9 8 76 56 2 9 28 45 76 1 87 7 6 35 83 7 6 77 79 7 7 28 75 6 7 84 71 3 8 43 66 8 9 00 61 9 9 55 50 84 1 94 9 6 51 90 6 6 93 86 4 7 45...

Page 5: ...KW 3 86 3 86 3 85 4 06 4 18 4 08 4 03 4 02 4 22 4 30 4 28 4 17 4 16 4 36 4 43 125 T C 24 9 24 1 23 8 27 6 30 4 26 6 24 7 24 4 28 3 30 9 27 9 27 6 24 9 28 6 31 0 S C 24 9 24 1 20 0 20 4 15 6 26 6 24 7...

Page 6: ...KW 5 11 5 06 5 04 5 38 5 65 5 36 5 27 5 24 5 56 5 82 5 59 5 54 5 41 5 72 5 97 125 T C 32 9 31 7 31 7 36 4 41 3 34 3 33 7 32 1 37 0 41 6 35 4 34 9 32 6 37 3 41 9 S C 32 9 31 7 27 5 27 8 21 6 34 3 33 7...

Page 7: ...KW 7 25 7 22 7 18 7 53 7 78 7 51 7 44 7 39 7 70 7 93 7 73 7 59 7 54 7 83 8 08 125 T C 41 2 39 8 40 6 45 7 50 0 42 9 41 3 41 6 46 1 50 4 44 0 41 7 41 4 46 4 50 6 S C 41 2 39 8 34 7 34 7 26 3 42 9 41 3...

Page 8: ...S C 59 9 58 8 52 5 51 9 36 9 61 1 58 0 54 3 53 6 37 3 60 9 59 3 55 7 55 2 37 9 KW 9 31 9 27 8 95 9 18 9 41 9 48 9 40 9 09 9 31 9 54 9 63 9 53 9 20 9 44 9 67 125 T C 56 7 57 2 58 8 66 5 66 6 58 0 55 4...

Reviews: