background image

813517-YTG-E-0114

Johnson Controls Unitary Products

5

*

Do not exceed minimum/maximum CFM limits shown under Air Flow Data.

APPLICATION LIMITATIONS

These units must be installed in accordance with all national
and local safety codes.
Air flow must be within the minimum and maximum limits
approved for electric heat, evaporator coils and outdoor units.

STATIC PRESSURE VS. AIRFLOW 
(BASED ON WET COIL)

APPLICATION FACTOR-RATED CFM VS. ACTUAL CFM

% OF RATED AIR FLOW

80%

90%

RATED CFM 110% 120%

CAPACITY FACTOR

0.96

0.98

1.00

1.02

1.03

HORIZONTAL - DUCT TYPE

Model

Airflow

Wet Coil

HD24S 

600 0.02 

800 0.09 

1000 0.19 

HD36S 

1000 0.19 

1200 0.28 

1400 0.38 

HD48S 

1200 0.14 

1400 0.19 

1600 0.25 

1800 0.32 

HD60S 

1600 0.16 

1800 0.20 

2000 0.25 

2200 0.30 

UNCASED UPFLOW - “A” TYPE

Model

Airflow

Wet Coil

UC18A 

600 0.16 

800 0.23 

1000 0.30 

UC18B 

600 0.14 

800 0.20 

1000 0.26 

UC24A 

600 0.15 

800 0.21 

1000 0.27 

UC24B 

600 0.13 

800 0.18 

1000 0.23 

UC30A 

800 0.21 

1000 0.27 

1200 0.33 

UC30B 

800 0.18 

1000 0.23 

1200 0.29 

UC36A 

1000 0.24 

1200 0.32 

1400 0.40 

UC36B 

1000 0.15 

1200 0.22 

1400 0.28 

UC36C 

1000 0.10 

1200 0.15 

1400 0.20 

UC42B 

1200 0.21 

1400 0.28 

1600 0.34 

UC42C 

1200 0.14 

1400 0.19 

1600 0.24 

1800 0.28 

UC48C 

1200 0.18 

1400 0.24 

1600 0.29 

1800 0.35 

UC48D 

1200 0.14 

1400 0.20 

1600 0.25 

1800 0.30 

UC60C 

1600 0.28 

1800 0.33 

2000 0.38 

2200 0.43 

UC60D 

1600 0.21 

1800 0.27 

2000 0.32 

2200 0.38 

Summary of Contents for FC18A3XC1

Page 1: ...installation HD Models Horizontal Duct Coils Dedicated horizontal slab coil available for both cooling and heat pump applications Field transition may be required FEATURES Rust proof plastic drain pa...

Page 2: ...62 36 7 29 2 23 8 19 9 70 57 31 5 27 6 22 4 18 8 FC36A PC36A 1150 85 72 46 0 41 9 37 4 32 9 80 67 36 8 32 5 28 5 24 2 75 62 28 8 24 1 26 4 19 6 70 57 24 7 22 9 21 1 19 6 FC36 B C PC36 B C 1250 85 72 5...

Page 3: ...2 9 19 2 MC36A 1150 85 72 46 8 42 6 38 1 33 6 80 67 37 5 33 1 29 1 24 7 75 62 29 3 24 6 26 8 20 0 70 57 25 1 23 2 21 4 20 0 MC36B 1250 85 72 52 0 47 3 42 3 37 3 80 67 41 7 36 8 32 3 27 4 75 62 32 5 27...

Page 4: ...Sensible Capacity Model Coil Rated CFM Entering Air F Dry Wet Bulb MBH Evaporator Temperature and Corresponding Pressure F PSIG 35 61 5 40 68 5 45 76 0 50 84 0 Uncased Upflow UC18 A B 600 85 72 23 3 2...

Page 5: ...02 800 0 09 1000 0 19 HD36S 1000 0 19 1200 0 28 1400 0 38 HD48S 1200 0 14 1400 0 19 1600 0 25 1800 0 32 HD60S 1600 0 16 1800 0 20 2000 0 25 2200 0 30 UNCASED UPFLOW A TYPE Model Airflow Wet Coil UC18A...

Page 6: ...2200 0 46 FC48D PC48D 1600 0 25 1800 0 30 2000 0 35 2200 0 40 FC60C PC60C 1600 0 28 1800 0 33 2000 0 38 2200 0 43 FC60D PC60D 1600 0 21 1800 0 27 2000 0 32 2200 0 38 FC62D 1600 0 18 1800 0 23 2000 0 2...

Page 7: ...YPE Model Application Refrig Conn Types Face Area Sq Ft Rows Deep Fin Per In Coil Size Tube Geometry Tube Dia Fin Type TXV Operating Weight Lbs HD24S3XC1 Cooling Heat Pump Sweat 3 67 3 12 22 x 24 1 x...

Page 8: ...8A3XC1 Cooling Heat Pump Sweat 3 4 2 14 2 14 x 17 5 1 x 0 866 3 8 Enhanced None 36 PC18B3XC1 Sweat 3 4 2 14 2 14 x 17 5 1 x 0 866 3 8 Enhanced None 37 PC24A3XC1 Cooling Heat Pump Sweat 4 38 2 14 2 18...

Page 9: ...12 2 16 x 17 5 1 x 0 866 3 8 Enhanced None 67 MC36A3XC1 Cooling Heat Pump Sweat 4 86 2 14 2 20 x 17 5 1 x 0 866 3 8 Enhanced None 64 MC36B3XC1 Cooling Heat Pump Sweat 4 86 2 14 2 20 x 17 5 1 x 0 866 3...

Page 10: ...lengths See Application Data part number 247077 20 1 4 D 20 3 8 Opening C A B 21 1 2 BOTTOM OPENING DIMENSIONS Models Dimensions 1 Refrigerant Connections 2 Height Width Opening Widths Line Size A B C...

Page 11: ...1 2 16 3 8 16 1 2 PC43C 22 5 8 21 19 7 8 20 PC48C 25 3 8 21 19 7 8 20 PC48D 24 5 8 24 1 2 23 3 8 23 1 2 PC60C 27 1 2 21 19 7 8 20 PC60D 26 7 8 24 1 2 23 3 8 23 1 2 1 All dimensions are in inches 2 Re...

Page 12: ...T SECONDARY DRAIN CONN OPENING FOR 3 4 NPT PRIMARY DRAIN CONN 7 8 1 7 8 4 1 8 1 3 8 OUTLET SAME SIZE AS INLET 3 4 FLANGE DIMENSIONS HD Coils Models Dimensions 1 Refrigerant Connections 2 Height Width...

Reviews: