background image

813517-YTG-E-0114

Johnson Controls Unitary Products

11

Models

Dimensions

 1

Refrigerant 

Connections 

2

Height

Width

Opening Widths

Line Size

A

B

C

D

Liquid

Vapor

PC18A

17-3/4

14-1/2

13-3/8

13-1/2

 3/8

 3/4

PC18B

17    

17-1/2

16-3/8

16-1/2

PC24A

21-7/8

14-1/2

13-3/8

13-1/2

PC24B

21-3/8

17-1/2

16-3/8

16-1/2

PC30A

21-7/8

14-1/2

13-3/8

13-/2

PC30B

21-3/8

17-1/2

16-3/8

16-1/2

PC32A

20    

14-1/2

13-3/8

13-1/2

PC35B

18-7/8

17-1/2

16-3/8

16-1/2

PC35C

18-3/4

21    

19-7/8

20    

PC36A

23-7/8

14-1/2

13-3/8

13-1/2

7/8

PC36B

23-1/8

17-1/2

16-3/8

16-1/2

PC36C

22-7/8

21    

19-7/8

20    

PC37A

23-7/8

14-1/2

13-3/8

13-1/2

3/4

PC42B

27-5/8

17-1/2

16-3/8

16-1/2

7/8

PC42C

27-1/8

21    

19-7/8

20    

PC43B

23-1/8

17-1/2

16-3/8

16-1/2

PC43C

22-5/8

21    

19-7/8

20    

PC48C

25-3/8

21    

19-7/8

20    

PC48D

24-5/8

24-1/2

23-3/8

23-1/2

PC60C

27-1/2

21    

19-7/8

20    

PC60D

26-7/8

24-1/2

23-3/8

23-1/2

1 All dimensions are in inches.
2 Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.

BOTTOM
OPENING
DIMENSIONS

20 1/4”

D

-

20

3/8”

(Opening)

A

C

(Opening)

12”

B

21 1/2”

-

-

Models

Dimensions

 1

Refrigerant

Connections 

2

Height

Width

Line Size

A

B

Liquid

Vapor

UC18A

17

13

 3/8

 3/4

UC18B

16-1/2

16

UC24A

21

13

UC24B

20-1/2

16

UC30A

21

13

UC30B

20-1/2

16

UC36A

23-1/2

13

7/8

UC36B

22-1/2

16

UC36C

22

19-1/2

UC42B

26-1/2

16

UC42C

25-1/2

19-1/2

UC48C

23-1/2

19-1/2

UC48D

23

23

UC60C

25-1/2

19-1/2

UC60D

25

23

1 All dimensions are in inches.
2 Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.

21.0

A

B

Summary of Contents for FC18A3XC1

Page 1: ...installation HD Models Horizontal Duct Coils Dedicated horizontal slab coil available for both cooling and heat pump applications Field transition may be required FEATURES Rust proof plastic drain pa...

Page 2: ...62 36 7 29 2 23 8 19 9 70 57 31 5 27 6 22 4 18 8 FC36A PC36A 1150 85 72 46 0 41 9 37 4 32 9 80 67 36 8 32 5 28 5 24 2 75 62 28 8 24 1 26 4 19 6 70 57 24 7 22 9 21 1 19 6 FC36 B C PC36 B C 1250 85 72 5...

Page 3: ...2 9 19 2 MC36A 1150 85 72 46 8 42 6 38 1 33 6 80 67 37 5 33 1 29 1 24 7 75 62 29 3 24 6 26 8 20 0 70 57 25 1 23 2 21 4 20 0 MC36B 1250 85 72 52 0 47 3 42 3 37 3 80 67 41 7 36 8 32 3 27 4 75 62 32 5 27...

Page 4: ...Sensible Capacity Model Coil Rated CFM Entering Air F Dry Wet Bulb MBH Evaporator Temperature and Corresponding Pressure F PSIG 35 61 5 40 68 5 45 76 0 50 84 0 Uncased Upflow UC18 A B 600 85 72 23 3 2...

Page 5: ...02 800 0 09 1000 0 19 HD36S 1000 0 19 1200 0 28 1400 0 38 HD48S 1200 0 14 1400 0 19 1600 0 25 1800 0 32 HD60S 1600 0 16 1800 0 20 2000 0 25 2200 0 30 UNCASED UPFLOW A TYPE Model Airflow Wet Coil UC18A...

Page 6: ...2200 0 46 FC48D PC48D 1600 0 25 1800 0 30 2000 0 35 2200 0 40 FC60C PC60C 1600 0 28 1800 0 33 2000 0 38 2200 0 43 FC60D PC60D 1600 0 21 1800 0 27 2000 0 32 2200 0 38 FC62D 1600 0 18 1800 0 23 2000 0 2...

Page 7: ...YPE Model Application Refrig Conn Types Face Area Sq Ft Rows Deep Fin Per In Coil Size Tube Geometry Tube Dia Fin Type TXV Operating Weight Lbs HD24S3XC1 Cooling Heat Pump Sweat 3 67 3 12 22 x 24 1 x...

Page 8: ...8A3XC1 Cooling Heat Pump Sweat 3 4 2 14 2 14 x 17 5 1 x 0 866 3 8 Enhanced None 36 PC18B3XC1 Sweat 3 4 2 14 2 14 x 17 5 1 x 0 866 3 8 Enhanced None 37 PC24A3XC1 Cooling Heat Pump Sweat 4 38 2 14 2 18...

Page 9: ...12 2 16 x 17 5 1 x 0 866 3 8 Enhanced None 67 MC36A3XC1 Cooling Heat Pump Sweat 4 86 2 14 2 20 x 17 5 1 x 0 866 3 8 Enhanced None 64 MC36B3XC1 Cooling Heat Pump Sweat 4 86 2 14 2 20 x 17 5 1 x 0 866 3...

Page 10: ...lengths See Application Data part number 247077 20 1 4 D 20 3 8 Opening C A B 21 1 2 BOTTOM OPENING DIMENSIONS Models Dimensions 1 Refrigerant Connections 2 Height Width Opening Widths Line Size A B C...

Page 11: ...1 2 16 3 8 16 1 2 PC43C 22 5 8 21 19 7 8 20 PC48C 25 3 8 21 19 7 8 20 PC48D 24 5 8 24 1 2 23 3 8 23 1 2 PC60C 27 1 2 21 19 7 8 20 PC60D 26 7 8 24 1 2 23 3 8 23 1 2 1 All dimensions are in inches 2 Re...

Page 12: ...T SECONDARY DRAIN CONN OPENING FOR 3 4 NPT PRIMARY DRAIN CONN 7 8 1 7 8 4 1 8 1 3 8 OUTLET SAME SIZE AS INLET 3 4 FLANGE DIMENSIONS HD Coils Models Dimensions 1 Refrigerant Connections 2 Height Width...

Reviews: