background image

TECHNICAL GUIDE

ADD - ON COILS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS

MODELS: MC, PC, FC, HD, UC
600 - 2000 CFM     1.5 - 5 TON COILS

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.
Additional rating information can be found at 

www.ahridirectory.org

UPFLOW/DOWNFLOW

FULL CASED

FC

FULL CASED

MULTI-POSITION

MC

UPFLOW

PARTIAL CASED

PC

HORIZONTAL

DUCT

HD

UPFLOW

UNCASED

UC

ISO 9001

Certified Quality

Management System

813517-YTG-E-0114

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

 

Heating

Air Conditioning

R

DESCRIPTION

These evaporator coils are designed to be installed with UPG fur-
naces or modular air handlers and matched with UPG cooling
and heat pump outdoor units. All coil models are available as
“flex-coil” units without a factory installed metering device. Flex-
coil models allow these coils to be used with R-22 or R-410A for
added flexibility to meet refrigerant system choice. An orifice
metering device or a R-410A TXV should be installed in the field
to meet your system requirements.

FC Models, Full Case Coils - 

Full cased coils are suitable for

use in upflow or downflow applications.

MC Models, Multi-Position Coils - 

MC coils have the added

flexibility that allow them to be installed in any position - upflow,
downflow, or horizontal right or left. This coil can be easily
installed with a UPG furnace or modular air handler in any config-
uration.

PC Models, Partial Case Coils - 

These coils are designed for

installation on top of upflow furnaces. The partial case height on
these coils allows for the flexibility of fabricating the upper portion
of the coil casing in the field. The partial cased coils are for use in
upflow only applications.

UC Models, Uncased Coils - 

These coils are designed for instal-

lation on top of upflow furnaces, and they are to be used for only
upflow applications. The uncased coils allows field modification of
the furnace duct for the coil installation. 

HD Models, Horizontal Duct Coils - 

Dedicated horizontal, slab

coil available for both cooling and heat pump applications. Field
transition may be required.

FEATURES

Rust-proof plastic drain pans - 

The vertical and horizontal drain

pans on these coils are made of a fiberglass reinforced thermoset
polymer that will not rust or compromise stability at high tempera-
tures. 

Insulated Cabinet - 

Evaporator coil cabinets are thermally insu-

lated with foil faced insulation to prevent sweating. HD coils use
fiberglass Tuf-Skin® insulation.

Internally Clean - 

All evaporator coils are factory leak-tested,

dehydrated, sealed and shipped with a holding charge. The suc-
tion and liquid lines are sealed with spun copper fittings with easy
access to attach line set.

Durable Finish Inside and Out - 

Coil casings are made of pre-

painted steel. Pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep. All
internal metal parts are made of G90 galvanized steel.

Optimum Heat Transfer - 

Using the latest in heat transfer tech-

nology, staggered rows of copper tubes are mechanically
expanded into aluminum fins to provide optimum air to surface
contact for ample moisture removal as well as high performance
ratings.

ACCESSORIES

Refer to Price Manual for specific model numbers.

TXV Kits - 

Thermal expansion valve kits are available for flex-coil

applications, for converting R-22 to R-410A refrigerant, or as a
service replacement. All TXV kits are non-braze. All connections
are bolt-on including the valve assembly and equalizer tube. No
orifice or any other metering device is to be used in conjunction
with the TXV.

Coil Casing Without Coil - 

Coil casings are available in four

widths that can be installed with the furnace or modular air han-
dler during initial installation. This option is available to allow the
installer the flexibility to add the coil at a later date without duct
modifications.

UVC Germicidal Light - 

The UVC technology effectively pre-

vents mold, bacteria, and other microorganisms that develop in
air handling systems. The UVC Light Kit provides safe, continu-
ous cleaning while actually saving money by reducing HVAC sys-
tem maintenance and energy consumption.

Summary of Contents for FC18A3XC1

Page 1: ...installation HD Models Horizontal Duct Coils Dedicated horizontal slab coil available for both cooling and heat pump applications Field transition may be required FEATURES Rust proof plastic drain pa...

Page 2: ...62 36 7 29 2 23 8 19 9 70 57 31 5 27 6 22 4 18 8 FC36A PC36A 1150 85 72 46 0 41 9 37 4 32 9 80 67 36 8 32 5 28 5 24 2 75 62 28 8 24 1 26 4 19 6 70 57 24 7 22 9 21 1 19 6 FC36 B C PC36 B C 1250 85 72 5...

Page 3: ...2 9 19 2 MC36A 1150 85 72 46 8 42 6 38 1 33 6 80 67 37 5 33 1 29 1 24 7 75 62 29 3 24 6 26 8 20 0 70 57 25 1 23 2 21 4 20 0 MC36B 1250 85 72 52 0 47 3 42 3 37 3 80 67 41 7 36 8 32 3 27 4 75 62 32 5 27...

Page 4: ...Sensible Capacity Model Coil Rated CFM Entering Air F Dry Wet Bulb MBH Evaporator Temperature and Corresponding Pressure F PSIG 35 61 5 40 68 5 45 76 0 50 84 0 Uncased Upflow UC18 A B 600 85 72 23 3 2...

Page 5: ...02 800 0 09 1000 0 19 HD36S 1000 0 19 1200 0 28 1400 0 38 HD48S 1200 0 14 1400 0 19 1600 0 25 1800 0 32 HD60S 1600 0 16 1800 0 20 2000 0 25 2200 0 30 UNCASED UPFLOW A TYPE Model Airflow Wet Coil UC18A...

Page 6: ...2200 0 46 FC48D PC48D 1600 0 25 1800 0 30 2000 0 35 2200 0 40 FC60C PC60C 1600 0 28 1800 0 33 2000 0 38 2200 0 43 FC60D PC60D 1600 0 21 1800 0 27 2000 0 32 2200 0 38 FC62D 1600 0 18 1800 0 23 2000 0 2...

Page 7: ...YPE Model Application Refrig Conn Types Face Area Sq Ft Rows Deep Fin Per In Coil Size Tube Geometry Tube Dia Fin Type TXV Operating Weight Lbs HD24S3XC1 Cooling Heat Pump Sweat 3 67 3 12 22 x 24 1 x...

Page 8: ...8A3XC1 Cooling Heat Pump Sweat 3 4 2 14 2 14 x 17 5 1 x 0 866 3 8 Enhanced None 36 PC18B3XC1 Sweat 3 4 2 14 2 14 x 17 5 1 x 0 866 3 8 Enhanced None 37 PC24A3XC1 Cooling Heat Pump Sweat 4 38 2 14 2 18...

Page 9: ...12 2 16 x 17 5 1 x 0 866 3 8 Enhanced None 67 MC36A3XC1 Cooling Heat Pump Sweat 4 86 2 14 2 20 x 17 5 1 x 0 866 3 8 Enhanced None 64 MC36B3XC1 Cooling Heat Pump Sweat 4 86 2 14 2 20 x 17 5 1 x 0 866 3...

Page 10: ...lengths See Application Data part number 247077 20 1 4 D 20 3 8 Opening C A B 21 1 2 BOTTOM OPENING DIMENSIONS Models Dimensions 1 Refrigerant Connections 2 Height Width Opening Widths Line Size A B C...

Page 11: ...1 2 16 3 8 16 1 2 PC43C 22 5 8 21 19 7 8 20 PC48C 25 3 8 21 19 7 8 20 PC48D 24 5 8 24 1 2 23 3 8 23 1 2 PC60C 27 1 2 21 19 7 8 20 PC60D 26 7 8 24 1 2 23 3 8 23 1 2 1 All dimensions are in inches 2 Re...

Page 12: ...T SECONDARY DRAIN CONN OPENING FOR 3 4 NPT PRIMARY DRAIN CONN 7 8 1 7 8 4 1 8 1 3 8 OUTLET SAME SIZE AS INLET 3 4 FLANGE DIMENSIONS HD Coils Models Dimensions 1 Refrigerant Connections 2 Height Width...