Multipliers for determining the performance with other indoor sections.
*
= Single-phase outdoor units only.
*
= Single-phase outdoor units only.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
EABD-F042S, EABD-(T,W)042S**
EVAPORATOR COIL MODEL NO
FC/MC/PC/UC48
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1200
1400
1600
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
51.7
3.1
4.3
52.6
3.0
4.4
53.4
2.9
4.5
70
49.6
3.2
3.9
50.4
3.2
4.0
51.3
3.1
4.1
80
47.4
3.4
3.6
48.3
3.3
3.7
49.2
3.3
3.8
47
60
40.4
2.8
3.6
42.2
2.7
3.8
44.0
2.7
4.0
70
39.7
3.0
3.4
42.0
2.9
3.6
42.5
2.8
3.6
80
39.1
3.1
3.2
40.1
3.1
3.3
41.1
3.0
3.4
40
60
38.4
2.7
3.6
39.1
2.6
3.7
39.8
2.6
3.7
70
35.7
2.8
3.3
36.9
2.7
3.3
38.1
2.7
3.4
80
33.1
2.9
2.9
34.8
2.9
3.0
36.5
2.9
3.1
30
60
33.5
2.5
3.3
33.4
2.5
3.3
33.3
2.4
3.3
70
31.0
2.6
3.0
31.7
2.6
3.0
32.3
2.5
3.0
80
28.6
2.7
2.7
30.0
2.7
2.8
31.3
2.7
2.8
17
60
27.1
2.3
2.9
27.4
2.3
2.9
27.7
2.3
2.9
70
25.2
2.4
2.6
25.0
2.4
2.6
26.4
2.4
2.6
80
23.3
2.5
2.4
24.1
2.5
2.4
25.0
2.4
2.4
10
60
24.1
2.2
2.7
24.3
2.2
2.7
24.6
2.1
2.6
70
22.6
2.3
2.5
22.9
2.2
2.4
23.2
2.2
2.4
80
21.2
2.3
2.2
21.5
2.3
2.2
21.9
2.3
2.2
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
**
For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.
Air Handler
Coil
T.C.
S.C.
KW
MA14D
FC/MC48D
1.00
1.00
1.00
MA16C
FC/MC48C
1.00
1.00
1.00
AHP/SHP48
–
1.00
1.02
1.02
MV16C*
FC/MC48C
0.99
0.97
0.96
MV20D*
FC/MC48D
0.99
0.97
0.96
AV/SV48*
–
0.99
0.97
0.96
–
HD48
0.99
1.00
0.99
Variable Speed
Furnace *
Coil
T.C.
S.C.
KW
(F,L)L8VC20
FC/MC/PC48C
0.99
0.98
0.97
FL9(C,V)C16
FC/MC/PC48C
0.99
0.98
0.97
FL9(C,V)C20
FC/MC/PC48C
0.98
0.96
0.94
FL9(C,V)D20
FC/MC/PC48D
0.98
0.95
0.93
(F,L)L8VC20
HD48
0.99
0.97
0.96
FL9(C,V)C16
HD48
0.99
0.98
0.97
FL9(C,V)C20
HD48
0.99
0.98
0.97