CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - Upflow Furnace Coils
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
47
°
F
17
°
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
EABD-F018S
FC/MC/PC/UC18
18.0
3.62
1.46
10.5
2.28
1.35
8.00
HC18
17.9
3.60
1.46
10.4
2.28
1.34
8.00
EABD-F024S
FC/MC/PC/UC24
23.0
3.44
1.96
13.1
2.30
1.67
8.00
FC/MC/PC/UC30
23.0
3.44
1.96
13.1
2.30
1.67
8.00
HC30
23.0
3.42
1.97
13.0
2.28
1.67
8.00
HD24
23.0
3.44
1.96
13.1
2.30
1.67
8.00
EABD-F030S
FC/MC/PC35
30.0
3.66
2.48
16.2
2.22
2.14
8.00
FC/MC/PC/UC/42
30.0
3.66
2.48
16.2
2.22
2.14
8.00
HC36
30.0
3.66
2.48
16.1
2.22
2.12
8.00
HD36
30.0
3.66
2.48
16.2
2.22
2.14
8.00
EABD-(T,W)030S
FC/MC/PC35
29.0
3.66
2.32
15.7
3.66
1.25
8.00
FC/MC/PC/UC/42
29.0
3.66
2.32
15.7
3.66
1.25
8.00
HC36
29.0
3.66
2.32
15.6
3.66
1.24
8.00
HD36
29.0
3.66
2.32
15.7
3.66
1.25
8.00
EABD-F036S
FC/MC/PC35
34.4
3.44
2.93
20.4
2.50
2.39
8.40
FC/MC/PC/UC/42
34.4
3.44
2.93
20.4
2.50
2.39
8.40
FC/MC/PC/UC/48
36.0
3.86
2.73
22.4
2.78
2.36
9.00
HC42
35.8
3.86
2.72
22.4
2.78
2.36
9.00
HD36
36.0
3.86
2.73
22.4
2.78
2.36
9.00
EABD-(T,W)036S
FC/MC/PC35
34.0
3.66
2.72
20.2
3.66
1.61
8.00
FC/MC/PC/UC/42
34.0
3.66
2.72
20.2
3.66
1.61
8.00
FC/MC/PC/UC/48
35.0
3.66
2.80
21.8
3.66
1.74
8.00
HC42
35.0
3.66
2.80
21.9
3.66
1.75
8.00
HD36
36.0
3.66
2.88
22.4
3.66
1.79
8.00
EABD-F042S
FC/MC/PC/UC48
42.0
3.62
3.40
25.0
2.56
2.86
8.50
HD48
41.5
3.62
3.36
25.0
2.56
2.86
8.50
EABD-(T,W)042S
FC/MC/PC/UC48
41.0
3.66
3.28
24.4
3.66
1.95
8.00
HD48
40.5
3.66
3.24
24.4
3.66
1.95
8.00
EABD-F048S
FC/MC/PC/UC60
48.0
3.50
4.02
29.6
2.34
3.71
8.00
HC60
48.0
3.50
4.02
29.6
2.34
3.71
8.00
HD60
48.0
3.50
4.02
29.6
2.34
3.71
8.00
MC61
48.0
3.50
4.02
29.6
2.34
3.71
8.00
EABD-(T,W)048S
FC/MC/PC/UC60
47.0
3.66
3.76
29.0
3.66
2.32
8.00
HC60
47.0
3.66
3.76
29.0
3.66
2.32
8.00
HD60
47.0
3.66
3.76
29.0
3.66
2.32
8.00
MC61
47.0
3.66
3.76
29.0
3.66
2.32
8.00
EABD-F060S
FC/MC/PC/UC60
58.0
3.52
4.83
35.0
2.32
4.42
8.00
HC60
57.5
3.50
4.81
34.8
2.30
4.43
8.00
HD60
58.0
3.52
4.83
35.0
2.32
4.42
8.00
MC61
58.0
3.52
4.83
35.0
2.32
4.42
8.00
EABD-(T,W)060S
FC/MC/PC/UC60
57.0
3.66
4.56
34.4
3.66
2.75
8.00
HC60
56.5
3.66
4.52
34.2
3.66
2.73
8.00
HD60
57.0
3.66
4.56
34.4
3.66
2.75
8.00
MC61
57.0
3.66
4.56
34.4
3.66
2.75
8.00
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.