18. Remove cross flow blade and motor
19. Remove cushion rubber
STEPS
PROCEDURES
Blade
Motor
a. Remove screws fixing cross
flow blade and motor.
b. Remove the motor sub-assy.
c. Separate two cross flow blade.
Cushion Rubber
a. Remove the cushion rubber
on cross flow blade.
b. Remove the cushion rubber
from the base.