923180-UTG-A-1112
12
Johnson Controls Unitary Products
Notes:
Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent. (Thermistor thermometer).
Connecting piping condition: 25 ft.
P: pressure of air pipe connected to the indoor and outdoor units (gas valve side),
T1: Inlet and outlet temperature for evaporator,
T2: Inlet and outlet temperature for condenser.
SOUND DATA
Temperature Condition (°F)
Model name
Standard
Pressure
Heat Exchanger
Pipe Temperature
Indoor Fan
Mode
Outdoor Fan
Mode
Compressor
Frequency (Hz)
Indoor
Outdoor
P (MPa)
T1 (°F)
T2 (°F)
COOLING
80/66.9
95/75
30K
0.9
46.4 to 53.6
124 to 98.7
High
High
65
36K
0.88
46.8 to 52.8
127 to 96.8
67
HEATING
70/60.1
47/43
30K
3.1
128.4 to 101
35 to 38.9
High
High
68
36K
3.56
134.4 to 102
36 to 39
61
Noise/dB(A)
40
45
30
35
Indoor side noise when blowing
Indoor fan motor rotating speed
Low
Middle
High
Super High
Noise/dB(A)
12K
09K
12K
09K
Outdoor side noise
30
40
50
60
0
20
40
60
80
100
Compressor frequency/Hz
09K & 12K Unit
50
55
40
45
35
Indoor side noise when blowing
Indoor fan motor rotating speed
Compressor frequency/Hz
Low
Middle
High
Super High
60
50
40
30
20
0
20
40
60 100
80
Noise/dB(A)
Noise/dB(A)
18K
24K
18K
24K
Outdoor side noise
18K & 24K Unit