360101-XTG-B-0508

Johnson Controls Unitary Products

3

STANDARD FEATURES/BENEFITS (CONT.)

UTILITY CONNECTIONS MADE EASY -

 Electrical utility 

knockouts are provided through the bottom as well as the side 
of the unit. Utility connections can be made quickly and with a 
minimum amount of field labor. A field supplied and  field 
installed electrical disconnect switch must be installed.

CONVERTIBLE AIRFLOW DESIGN -

 The bottom duct 

openings are covered when they leave the factory ready to be 
used for a side supply / side return application. If a bottom supply 
/ bottom return application is desired, you simply remove the two 
panels from the bottom of the unit and place them in the side 
supply / side return duct openings. No panel cutting is required 
and no accessory panel is necessary. Convertible airflow design 
allows maximum field flexibility and minimum inventory.

CONDENSATE PAN -

 A non-corrosive, long-lasting, water-tight 

pan is positioned below the evaporator coil to collect and drain 
all condensate. Less collection of stagnate condensate will 
build-up. The condensate pan conforms to ASHRAE 62-89 
standards (Ventilation for Acceptable Indoor Air Quality).

CONDENSATE DRAIN -

 The heavy duty, 3/4 inch NPTI copper 

connection is more tolerable during installation and is more 
durable over time. The connection is rigidly mounted to assure 
proper fit and leak tight seal.

DURABLE FINISH -

 With a heavy duty cabinet made of powder-

painted, galvanized steel the neutral color blends into 
surrounding areas. The powered paint, provides a better paint to 
steel bond, which resists corrosion and rust creep. The special 
primer formulas and glossy earth tone finish insure less fading 
when exposed to sunlight and offers a more attractive on site 
appearance. This paint finish exceeds ASTM-B117 standards for 
1000 hours salt spray rating, the highest in the industry.

FULL PERIMETER BASE RAILS -

 The easily removable base 

rails provide a solid foundation for the entire unit and protects 
the unit during shipment. The rails provide fork lift access from 
all sides, and rigging holes are also provided so that an 
overhead crane can be used to place the units on a roof. On 
applications when the unit is placed on a pad, the base will 
keep the unit off the pad to deter corrosion. On applications 
where height is limited, the 2-3/8 inch high base rails may be 
removed on location.

MORE ATTRACTIVE APPEARANCE -

 A single piece “Water 

Shed” top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation and 
provides a wider variety of installations. The one piece design 
adds greater water integrity. Rounded corners with water drip 
edges add to the attractive appearance. The cabinet panels 
have a non-fibrous insulation that does not add insulation fibers 
into conditioned area.

TOP DISCHARGE -

 The top discharge condenser fan does not 

disrupt neighboring areas and does not dry-out vegetation 
surrounding the unit. The warm air from the top mounted fan is 
blown up away from the structure and any landscaping. This 
allows compact location on multi-unit applications.

CONDENSER COIL GRILLE -

 A multi-piece totally enclosed, 

rigidly mounted condenser coil grille provides protection from 
objects and personal after installation and provides protection 
during transit and installation.

LOW OPERATING SOUND LEVEL -

 The upward air flow carries 

the normal operating noise up and away from the living area. The 
rigid top panel effectively isolates any motor sound. Isolator 
mounted compressor and the rippled fins of the condenser coil 
muffle the normal fan motor and compressor operating sounds. 
The unique formed base pan also aids in sound alterations with it's 
“Super-Structure” design. This design strategically places 
embossments in the pan for optimum strength and rigidity.

FAN SYSTEM -

 All models operate over a wide range of design 

conditions with a 3-speed direct-drive fan motor. These units 
easily match all types of applications and provides greater on 
site flexibility to match comfort requirement.

SIMPLE CONTROL CIRCUIT -

 A low voltage printed circuit 

board contains a low voltage terminal strip. The electrical 
control box is not located in the compressor compartment. All 
wiring internal to the unit is color/number coded.

PROTECTED COMPRESSOR -

 The compressor is internally 

protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high pressure 
relief valve and a temperature sensor which protect the 
compressor if undesirable operating conditions occur.

EXCLUSIVE COIL DESIGN -

 Grooved copper tubes and 

enhanced aluminum fin construction improves heat transfer for 
maximum efficiency and durability.

LOW MAINTENANCE -

 Long life, permanently lubricated 

condenser and evaporator fan motor bearings need no annual 
maintenance adding greater reliability to the unit. Blower 
assembly can be easily removed for cleaning by the unique 
“Slip- Track” slide-out blower assembly.

SECURED SERVICE ACCESS PORTS -

 Protected, externally 

mounted, re-usable service access ports are provided on both 
the high and low lines for ease of evacuating and charging the 
system. No final field mounting required.

EASY SERVICE ACCESS -

 A large, single panel covers the 

electrical controls and makes servicing easy. The blower 
compartment has an additional large panel with a built-in 
handle tab. Removing this panel will allow the blower assembly 
to slide-out for easy removal for maintenance and ease of 
trouble shooting.

REPLACEMENT PARTS -

 The installer has no need to carry 

an inventory of unique parts or needs special training to replace 
any of the components parts for these units. All are easily 
obtained from Source 1 or other part houses.

FIELD-INSTALLED ACCESSORIES

ECONOMIZER DOWN DISCHARGE / SUPPLY KIT -

 

Modulating integrated economizer provides simultaneous 
operation between the mechanical cooling and economizer 

Summary of Contents for D2EB030

Page 1: ...ds to carry less inventory LOWER INSTALLATION COST Installation time and costs are reduced by easy power and control wiring connections The small base dimension means less space is required on the gro...

Page 2: ...3 60 POWER SUPPLY DEB MODELS 20 LIST OF TABLES Tbl Pg 1 PHYSICAL DATA 5 2 RATINGS ARI 5 3 COOLING CAPACITIES 2 1 2 TON DEB030 6 4 COOLING CAPACITIES 3 TON DEB036 7 5 COOLING CAPACITIES 3 1 2 TON DEB04...

Page 3: ...e condenser fan does not disrupt neighboring areas and does not dry out vegetation surrounding the unit The warm air from the top mounted fan is blown up away from the structure and any landscaping Th...

Page 4: ...ed side return and unit mounted down shot return applications Damper capable of providing 0 thru 50 of outdoor air field supplied Closes on power loss includes hood and screen assembly RECTANGLE TO RO...

Page 5: ...IL ROWS DEEP 1 1 1 1 1 FINS PER INCH 20 18 16 13 20 FACE AREA Sq Ft 8 3 8 3 11 7 16 4 16 4 CHARGE REFRIGERANT 22 lbs oz 3 13 3 10 4 8 5 15 5 15 FILTER FACE AREA Sq Ft Qty Size 2 14 2 14 x 22 COMPRESSO...

Page 6: ...Power Input kW 3 38 3 28 3 22 3 22 3 45 3 35 3 29 3 28 3 52 3 42 3 36 3 35 3 66 3 55 3 49 3 48 3 79 3 68 3 62 3 61 Sensible Capacity MBH 1 Entering Dry Bulb F 86 16 5 21 3 22 2 22 3 18 5 23 4 23 1 23...

Page 7: ...ut kW 4 05 3 92 3 93 3 85 4 07 3 94 3 95 3 87 4 09 3 96 3 97 3 89 4 15 4 02 4 02 3 95 4 21 4 08 4 08 4 00 Sensible Capacity MBH 1 Entering Dry Bulb F 86 17 5 23 3 25 0 24 4 19 9 26 3 26 6 26 0 22 3 29...

Page 8: ...20 4 22 4 47 4 35 4 27 4 29 4 54 4 42 4 34 4 35 4 69 4 57 4 48 4 50 4 84 4 71 4 63 4 64 Sensible Capacity MBH 1 Entering Dry Bulb F 86 22 4 29 3 30 8 31 2 24 8 32 1 32 0 32 4 27 3 34 9 33 1 33 6 29 3...

Page 9: ...21 5 21 5 49 5 43 5 34 5 33 5 62 5 55 5 46 5 45 5 72 5 66 5 56 5 55 5 83 5 76 5 66 5 65 Sensible Capacity MBH 1 Entering Dry Bulb F 86 27 0 33 2 37 8 37 4 29 6 36 1 38 3 37 9 32 3 39 1 38 8 38 3 34 3...

Page 10: ...58 7 07 6 90 6 79 6 75 7 25 7 06 6 96 6 91 7 47 7 28 7 17 7 12 7 69 7 50 7 38 7 33 Sensible Capacity MBH 1 Entering Dry Bulb F 86 33 5 42 4 45 0 45 3 37 5 47 1 46 9 47 2 41 4 51 8 48 8 49 1 44 9 53 7...

Page 11: ...657 1597 640 1542 623 1486 607 1431 590 1336 563 1240 537 Low 1385 520 1349 510 1312 500 1276 490 1235 480 060 5 0 High 2450 1213 2366 1165 2282 1117 2198 1068 2114 1020 1989 993 1864 967 1739 940 Me...

Page 12: ...E KW CAP MULTIPLIER 240 208 230 75 92 480 460 92 600 575 92 TABLE 11 ELECTRICAL DATA COOLING ELECTRIC HEAT MODEL DEB POWER SUPPLY COMPRESSOR COND FAN MOTORS SUPPLY AIR BLOWER MOTOR ELECTRIC HEAT ACCES...

Page 13: ...501546 1 15 0 18 24 8 25 25 048 460 3 60 7 1 55 0 0 8 2 0 2NP04501046 1 10 0 12 17 5 20 20 2NH04501546 1 15 0 18 25 1 30 30 2NH04502046 2 20 0 24 1 32 6 35 35 2NH04502546 2 25 0 30 1 40 1 45 45 060 46...

Page 14: ...RALL 4 1 2 UNIT CONDENSATE CONNECTION NPTI TRAP REQUIRED OVERALL SIDE SUPPLY AIR OPENING SIDE RETURN AIR OPENING COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN DIA KNOCKOUT HIGH VOLTAGE...

Page 15: ...2 UNIT WEIGHTS Unit Size Shipping Weight Operating Weight Corner Weights Economizer lbs Roof Curb lbs A B C D 030 333 328 85 81 82 86 40 8 70 14 75 036 338 333 91 80 78 88 042 347 342 94 83 80 91 048...

Page 16: ...OWER SUPPLY SUPPLY AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERMOSTAT SLAB ON GROUND INSTALLATION ROOF CURB INSTALLATION BOTTOM DUCT...

Page 17: ...ED PANELS 22 14 OPENING FOR RETURN AIR DUCT OPENING FOR SUPPLY AIR DUCT RECOMMENDED DUCT SIZE SUPPLY AIR DUCT x RETURN AIR DUCT x UNIT BASE RAIL UNIT BASE WOOD NAILER 8 MIN ABOVE FINISHED ROOF CURB FR...

Page 18: ...Controls Unitary Products FIGURE 9 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY DEB MODELS 15695BASH0301 SEE DETAIL A T2 M1 2 DETAIL A BLK BLK CCH L1 T1 OPTIONAL CCH S P CONFIGURATION BLK BLK CCH...

Page 19: ...0508 Johnson Controls Unitary Products 19 TYPICAL WIRING DIAGRAM NOTES TYPICAL WIRING DIAGRAM LEGEND FIGURE 10 TYPICAL WIRING DIAGRAM 208 230 3 60 POWER SUPPLY DEB MODELS 6 F 9 N O T U S E D 2 M 3 2...

Page 20: ...360101 XTG B 0508 20 Johnson Controls Unitary Products FIGURE 11 TYPICAL WIRING DIAGRAM 460 3 60 AND 575 3 60 POWER SUPPLY DEB MODELS 2...

Page 21: ...and base unit 10 Condensate pan shall be internally sloped and conform to ASHRAE 62 89 self draining standards with 3 4 NPTI copper ridged mount connection INDOOR EVAPORATOR FAN ASSEMBLY 1 Fan shall b...

Page 22: ...eset to prevent the heating element system from operating at an excessive temperature 3 The heating section assembly shall slide out of the unit for easy maintenance and service 4 Units with electric...

Page 23: ...360101 XTG B 0508 Johnson Controls Unitary Products 23...

Page 24: ...change without notice Printed in U S A 360101 XTG B 0508 Copyright 2008 by Johnson Controls Inc All rights reserved Supersedes 360101 XTG A 0108 Johnson Controls Unitary Products 5005 York Drive Norma...