246723-YTG-L-0807
Unitary Products Group
5
Go to
www.ari.org/aridirectory for the latest additional matches.
1 PH 13 SEER AC WITH AV / SV / F*FV VARIABLE SPEED
CZB01811
AV24
17
–
600
18.0
12.1
14.00
11.50
CZB02411
AV24
17
–
800
23.0
16.7
14.00
11.50
CZB03011
AV36
17
–
1000
30.0
21.9
14.00
11.50
CZB03611
AV36
17
–
1200
36.0
26.5
14.00
11.50
CZB04211
AV/SV48
24
–
1400
41.5
30.5
14.00
11.50
CZB04811
AV/SV48
24
–
1600
48.0
35.8
14.00
11.50
AV/SV60
24
–
1600
48.0
35.8
14.00
11.50
F*FV060
24
–
1600
48.0
36.5
13.25
11.00
CZB06011
AV/SV60
24
–
1800
57.0
40.8
14.00
11.50
F*FV060
24
–
1780
55.5
40.8
13.25
11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1
MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER
1,2
EER
TOTAL
SENS.
CZB01811
450
750
14,17
FC/MC/PC/UC18
600
18.0
12.1
13.00
11.00
14,17
FC/MC/PC/UC24
600
18.0
12.1
13.00
11.00
14,17
FC/MC/PC/UC30
600
18.0
12.1
13.00
11.00
14
HC18
570
18.0
12.1
13.00
11.00
CZB02411
600
1000
14,17
FC/MC/PC/UC24
800
23.2
16.9
13.00
11.00
14,17
FC/MC/PC/UC30
800
23.2
16.9
13.00
11.00
14
HC30
760
22.6
16.5
13.00
11.00
–
HD24
800
22.6
16.5
13.00
11.00
CZB03011
800
1200
14,17
FC/MC/PC/UC30
1000
29.8
21.7
13.00
11.00
14,17,21
FC/MC/PC/UC36
1000
30.0
21.9
13.00
11.00
17
HC36
950
30.0
21.9
13.00
11.00
–
HD36
1000
30.0
21.9
13.00
11.00
CZB03611
1000
1400
17, 21
FC/MC/PC35
1200
36.0
26.5
13.00
11.00
14,17,21
FC/MC/PC/UC36
1200
35.6
26.3
13.00
11.00
17,21
FC/MC/PC/UC42
1200
36.0
26.5
13.00
11.00
17
HC36
1140
36.0
26.5
13.00
11.00
–
HD36
1200
35.8
26.4
13.00
11.00
CZB04211
1200
1600
21,24
FC/MC/PC/UC48
1400
41.0
30.2
13.00
11.00
24
HC60
1330
40.5
29.8
13.00
11.00
–
HD60
1400
40.0
29.4
13.00
11.00
CZB04811
1400
1800
21,24
FC/MC/PC/UC60
1600
48.0
35.8
13.00
11.00
24
HC60
1600
48.0
35.8
13.00
11.00
–
HD60
1600
48.0
35.8
13.00
11.00
CZB06011
1600
2000
21,24
FC/MC/PC/UC60
1800
55.5
39.7
13.00
11.00
24
HC60
1800
55.5
39.7
13.00
11.00
–
HD60
1800
55.5
39.7
13.00
11.00
24
MC61
1800
56.0
40.0
13.00
11.00
1
Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
2
TXV = Use 1TV900 series kit.