1 PH 13 SEER AC WITH AV / SV / F*FV VARIABLE SPEED

CZB01811

AV24

17

600

18.0

12.1

14.00

11.50

CZB02411

AV24

17

800

23.0

16.7

14.00

11.50

CZB03011

AV36

17

1000

30.0

21.9

14.00

11.50

CZB03611

AV36

17

1200

36.0

26.5

14.00

11.50

CZB04211

AV/SV48

24

1400

41.5

30.5

14.00

11.50

CZB04811

AV/SV48

24

1600

48.0

35.8

14.00

11.50

AV/SV60

24

1600

48.0

35.8

14.00

11.50

F*FV060

24

1600

48.0

36.5

13.25

11.00

CZB06011

AV/SV60

24

1800

57.0

40.8

14.00

11.50

F*FV060

24

1780

55.5

40.8

13.25

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8

0

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.

1

MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

MODEL

AIR HANDLER

COIL MODEL

1

COOLING

MODEL

W

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

UNIT MODEL

FURNACE

COIL

MODEL

COOLING

CFM RANGE

(MIN.-MAX.)

W

RATED 

CFM

NET MBH

SEER

1,2

EER

TOTAL

SENS.

CZB01811

450
750

14,17

FC/MC/PC/UC18

600

18.0

12.1

13.00

11.00

14,17

FC/MC/PC/UC24

600

18.0

12.1

13.00

11.00

14,17

FC/MC/PC/UC30

600

18.0

12.1

13.00

11.00

14

HC18

570

18.0

12.1

13.00

11.00

CZB02411

600

1000

14,17

FC/MC/PC/UC24

800

23.2

16.9

13.00

11.00

14,17

FC/MC/PC/UC30

800

23.2

16.9

13.00

11.00

14

HC30

760

22.6

16.5

13.00

11.00

HD24

800

22.6

16.5

13.00

11.00

CZB03011

800

1200

14,17

FC/MC/PC/UC30

1000

29.8

21.7

13.00

11.00

14,17,21

FC/MC/PC/UC36

1000

30.0

21.9

13.00

11.00

17

HC36

950

30.0

21.9

13.00

11.00

HD36

1000

30.0

21.9

13.00

11.00

CZB03611

1000
1400

17, 21

FC/MC/PC35

1200

36.0

26.5

13.00

11.00

14,17,21

FC/MC/PC/UC36

1200

35.6

26.3

13.00

11.00

17,21

FC/MC/PC/UC42

1200

36.0

26.5

13.00

11.00

17

HC36

1140

36.0

26.5

13.00

11.00

HD36

1200

35.8

26.4

13.00

11.00

CZB04211

1200
1600

21,24

FC/MC/PC/UC48

1400

41.0

30.2

13.00

11.00

24

HC60

1330

40.5

29.8

13.00

11.00

HD60

1400

40.0

29.4

13.00

11.00

CZB04811

1400
1800

21,24

FC/MC/PC/UC60

1600

48.0

35.8

13.00

11.00

24

HC60

1600

48.0

35.8

13.00

11.00

HD60

1600

48.0

35.8

13.00

11.00

CZB06011

1600
2000

21,24

FC/MC/PC/UC60

1800

55.5

39.7

13.00

11.00

24

HC60

1800

55.5

39.7

13.00

11.00

HD60

1800

55.5

39.7

13.00

11.00

24

MC61

1800

56.0

40.0

13.00

11.00

1

Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.

2

TXV = Use 1TV900 series kit.

Summary of Contents for CZB01811

Page 1: ...ressures by an internal pressure relief valve and factory installed high and low pressure controls Additional protection against moisture and debris is provided by factory installed liquid line filter...

Page 2: ...Area Sq Ft 14 86 14 86 17 15 17 15 20 58 20 58 20 58 Rows Deep 1 1 1 1 1 1 2 Fins Inch 22 22 22 22 22 22 22 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Inst...

Page 3: ...03 1TVM903 1TVM903 1TVM904 1TVM4C1 1TVM905 1TVM905 Factory R 410A Charge lbs oz 5 13 6 4 7 4 6 4 8 13 8 12 13 9 Indoor Coil1 2 Additional Charge Oz FC MC PC UC18A3X 5 FC MC PC UC18B3X 5 FC MC PC UC24A...

Page 4: ...17 MC18B 600 18 1 12 1 14 00 11 50 CZB02411 MV12B 17 MC24B 825 23 2 16 9 14 00 11 50 CZB03011 MV12B 17 MC36B 1000 30 6 22 3 14 00 11 50 CZB03611 MV12B 17 MC36B 1200 36 0 26 5 13 50 11 00 MV12B 17 MC42...

Page 5: ...DEL W RATED CFM NET MBH SEER EER TOTAL SENS COOLING CAPACITY Upflow Downflow Horizontal Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE MIN MAX W RATED CFM NET MBH SEER1 2 EER TOTAL...

Page 6: ...1000 30 0 21 9 13 50 11 00 P C V 9 B12 FC MC PC30B 17 1000 30 0 21 9 13 50 11 00 PV8 A12 FC MC PC36A 14 1000 30 0 22 3 14 00 11 50 PV9 A12 FC MC PC36A 14 1000 30 0 22 3 14 00 11 50 PV8 B16 FC MC PC36B...

Page 7: ...600 48 0 36 1 13 25 11 00 PV8 C20 HD60 21 1600 48 0 36 1 13 05 11 00 P C V 9 D20 HD60 24 1600 48 0 36 1 13 25 11 00 CZB06011 PV8 C20 FC PC60C 21 1730 55 5 39 7 13 10 11 00 P C V 9 C20 FC PC60C 21 1620...

Page 8: ...rmo stat 1H 1C auto manual changeover electronic programmable deluxe 7 day thermostat 1H 1C auto manual changeover electronic programmable For the most current accessory information refer to the price...

Page 9: ...1 16 7 18 3 17 4 19 4 20 4 S C 13 4 12 4 10 1 10 0 7 5 15 0 14 5 11 9 11 9 8 7 16 7 16 6 13 8 13 8 10 0 K W 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 6 1 5 105 T C 12 7 14 6 13 8 15 6 16...

Page 10: ...0 25 7 22 6 23 3 21 5 23 8 26 3 S C 18 6 16 5 14 3 14 5 11 5 20 5 19 8 16 5 16 8 12 9 22 3 23 0 18 7 19 1 14 3 K W 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 0 2 1 2 0 2 0 105 T C 17 4 18 3 18 0 2...

Page 11: ...7 23 5 18 8 K W 2 5 3 6 2 5 2 6 2 6 2 5 3 1 2 5 2 6 2 6 2 5 2 5 2 5 2 6 2 6 105 T C 22 4 11 2 24 3 26 1 29 5 24 4 23 7 25 2 27 3 30 4 26 3 26 2 26 0 28 5 31 4 S C 23 2 22 6 19 0 18 2 14 6 25 2 24 8 21...

Page 12: ...0 29 5 32 9 35 1 31 9 31 9 30 0 33 5 35 4 33 1 32 8 30 4 34 2 35 6 S C 28 9 28 3 23 5 23 8 18 6 30 0 29 8 25 0 25 5 19 8 31 1 31 2 26 6 27 1 21 0 K W 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3...

Page 13: ...37 2 36 3 30 9 30 2 23 2 38 9 38 9 33 2 32 5 24 5 K W 3 6 3 6 3 6 3 6 3 7 3 6 3 6 3 6 3 6 3 7 3 6 3 6 3 6 3 6 3 7 105 T C 33 5 34 7 34 5 37 5 42 0 35 0 35 7 35 3 38 4 42 8 36 5 36 7 36 2 39 3 43 6 S...

Page 14: ...47 9 52 4 45 2 45 9 43 1 48 5 52 4 47 0 46 9 43 8 49 1 52 4 S C 39 3 40 5 33 3 34 2 26 7 41 0 42 3 35 4 36 5 28 1 42 7 44 2 37 5 38 8 29 5 K W 4 2 4 2 4 1 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 3...

Page 15: ...1 38 5 29 3 40 8 49 9 44 1 40 8 30 6 43 1 52 8 48 4 43 1 31 9 K W 5 0 5 0 4 9 5 1 5 2 5 0 5 0 5 0 5 1 5 2 5 0 5 0 5 0 5 1 5 2 105 T C 46 4 47 7 46 5 52 4 55 6 47 1 48 9 48 1 53 4 56 4 47 8 50 1 49 6 5...

Page 16: ...o change without notice Printed in U S A 246723 YTG L 0807 Copyright by Unitary Products Group 2007 All rights reserved Supersedes 246723 YTG K 0507 Unitary 5005 Norman Products York OK Group Drive 73...