![York B1HH018 Installation Instructions Manual Download Page 9](http://html1.mh-extra.com/html/york/b1hh018/b1hh018_installation-instructions-manual_4191259009.webp)
Unitary Products Group
9
66297-YIM-C-0205
TABLE 13 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HH036)
TABLE 12 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HH036)
INDOOR DB
TEMPERATURE,
°
F
HEATING SUPERHEAT AT COMPRESSOR SUCTION,
°
F
-10
0
10
20
30
40
50
60
55
—
—
3.3
4.1
5.3
7.0
9.5
13.2
70
—
—
—
—
3.8
5.5
8.0
11.7
80
—
—
—
—
—
—
4.5
8.2
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
—
5.2
7.3
9.4
11.6
13.7
15.8
20.0
24.2
28.4
32.6
70
—
—
6.4
8.2
10.0
11.8
13.6
17.9
22.2
26.5
30.8
75
—
—
5.5
6.9
8.4
9.8
11.3
15.7
20.2
24.6
29.1
80
—
—
—
5.7
6.8
7.9
9.1
13.6
18.2
22.7
27.3
85
—
—
—
—
5.2
6.0
6.8
11.5
16.2
20.8
25.5
90
—
—
—
—
—
—
—
9.3
14.2
19.0
23.8
95
—
—
—
—
—
—
—
7.2
12.1
17.1
22.0
100
—
—
—
—
—
—
—
5.9
9.9
14.0
18.0
105
—
—
—
—
—
—
—
—
7.7
10.9
14.0
110
—
—
—
—
—
—
—
—
5.5
7.8
10.1
115
—
—
—
—
—
—
—
—
—
—
6.1
TABLE 10 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,000 CFM (B1HH030)
TABLE 11 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,000 CFM (B1HH030)
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
—
5.8
10.8
15.8
20.8
25.8
30.8
31.7
32.6
33.4
34.3
70
—
5.1
9.3
13.6
17.8
22.1
26.3
28.0
29.6
31.3
32.9
75
—
—
7.9
11.4
14.8
18.3
21.8
24.2
26.7
29.1
31.6
80
—
—
6.4
9.1
11.9
14.6
17.3
20.5
23.7
27.0
30.2
85
—
—
—
6.9
8.9
10.8
12.8
16.8
20.8
24.8
28.8
90
—
—
—
—
5.9
7.1
8.3
13.1
17.9
22.6
27.4
95
—
—
—
—
—
—
—
9.4
14.9
20.5
26.0
100
—
—
—
—
—
—
—
7.6
12.0
16.3
20.7
105
—
—
—
—
—
—
—
5.9
9.0
12.2
15.3
110
—
—
—
—
—
—
—
—
6.1
8.0
9.9
115
—
—
—
—
—
—
—
—
—
—
—
INDOOR DB
TEMPERATURE,
°
F
HEATING SUPERHEAT AT COMPRESSOR SUCTION,
°
F
-10
0
10
20
30
40
50
60
55
—
5.8
7.9
9.6
13.4
19.1
26.9
36.6
70
—
—
—
—
5.4
11.2
18.9
28.7
80
—
—
—
—
—
8.1
15.9
25.6