![York B1HA018A06 Installation Instruction Download Page 12](http://html1.mh-extra.com/html/york/b1ha018a06/b1ha018a06_installation-instruction_3622070012.webp)
12
Unitary Products Group
035-16004-001-A-0202
INDOOR DB
TEMPERATURE,
°
F
HEATING SUPERHEAT AT COMPRESSOR SUCTION,
°
F
-10
0
10
20
30
40
50
60
55
9.7
10.1
10.7
11.8
13.7
17.0
22.6
32.2
70
-
-
-
-
4.6
7.8
13.4
23.0
80
-
-
-
-
-
-
7.3
16.9
TABLE 14 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HA036)
TABLE 13 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HA036)
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
12.8
16.1
19.3
22.5
25.8
29.0
32.2
35.0
37.7
40.4
43.1
70
11.4
14.3
17.2
20.1
22.9
25.8
28.7
31.6
34.4
37.3
40.1
75
9.9
12.5
15.0
17.6
20.1
22.7
25.2
28.2
31.1
34.1
37.1
80
8.5
10.7
12.9
15.1
17.3
19.5
21.7
24.8
27.9
31.0
34.0
85
7.0
8.9
10.8
12.6
14.5
16.3
18.2
21.4
24.6
27.8
31.0
90
5.6
7.1
8.6
10.1
11.7
13.2
14.7
18.0
21.3
24.7
28.0
95
-
5.3
6.5
7.7
8.8
10.0
11.2
14.6
18.1
21.5
25.0
100
-
-
5.1
6.0
6.9
7.8
8.7
11.7
14.7
17.7
20.7
105
-
-
-
-
-
5.6
6.2
8.7
11.3
13.9
16.4
110
-
-
-
-
-
-
-
5.8
7.9
10.0
12.2
115
-
-
-
-
-
-
-
-
-
6.2
7.9
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
34.0
34.2
34.4
34.6
34.8
35.0
35.2
36.2
37.3
38.4
39.4
70
31.1
31.5
31.9
32.2
32.6
33.0
33.4
34.8
36.3
37.7
39.2
75
28.3
28.8
29.4
29.9
30.5
31.0
31.6
33.4
35.3
37.1
39.0
80
25.4
26.1
26.9
27.6
28.3
29.1
29.8
32.0
34.3
36.5
38.7
85
22.6
23.5
24.4
25.3
26.2
27.1
28.0
30.6
33.2
35.9
38.5
90
19.7
20.8
21.9
23.0
24.0
25.1
26.2
29.2
32.2
35.2
38.3
95
16.9
18.1
19.4
20.6
21.9
23.2
24.4
27.8
31.2
34.6
38.0
100
14.5
15.6
16.6
17.7
18.7
19.7
20.8
24.4
27.9
31.5
35.1
105
12.2
13.1
13.9
14.7
15.5
16.3
17.1
20.9
24.6
28.4
32.1
110
9.9
10.5
11.1
11.7
12.3
12.9
13.5
17.4
21.3
25.3
29.2
115
7.6
8.0
8.4
8.8
9.1
9.5
9.9
14.0
18.1
22.1
26.2
INDOOR DB
TEMPERATURE,
°
F
OUTDOOR TEMPERATURE,
°
F
-10
0
10
20
30
40
50
60
55
5.1
5.5
6.2
7.4
9.6
13.5
20.3
32.4
70
-
-
-
-
5.0
8.9
15.7
27.8
80
-
-
-
-
-
5.4
12.2
24.3
TABLE 15 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,400 CFM (B1HA042)