background image

Johnson Controls Unitary Products

5

5151060-YTG-F-1116

PHYSICAL & ELECTRICAL DATA - COOLING ONLY

Models

18B

24B

30B

36B

36C

Blower - Diameter x Width

10 x 8

10 x 8

10 x 8

10 x 8

11 x 10

Motor

HP

1/3 HP

1/3 HP

1/3 HP

1/2 HP

1/2 HP

Nominal RPM

1050

1050

1050

1050

1050

Voltage

208/230

208/230

208/230

208/230

208/230

Full Load Amps @230V

2.9

2.9

2.9

4.5

4.5

Filter

1

Type

DISPOSABLE OR PERMANENT

Size

16 x 20 x 1

16 x 20 x 1

16 x 20 x 1

16 x 20 x 1

20 x 20 x 1

Permanent Type Kit

1PF0601

1PF0601

1PF0601

1PF0601

1PF0602

Shipping Operating Weight (lbs.)

91/85

93/87

119/113

119/113

120/114

Models

42C

48C

48D

60C

60D

Blower - Diameter x Width

11 x 10

11 x 10

11 x 10

11 x 10

11 x 10

Motor

HP

1/2 HP

3/4 HP

3/4 HP

3/4 HP

3/4 HP

Nominal RPM

1050

1050

1050

1050

1050

Voltage

208/230

208/230

208/230

208/230

208/230

Full Load Amps @230V

4.5

7.0

7.0

7.0

7.0

Filter

1

Type

DISPOSABLE OR PERMANENT

Size

20 x 20 x 1

20 x 20 x 1

22 x 20 x 1

20 x 20 x 1

22 x 20 x 1

Permanent Type Kit

1PF0602

1PF0602

1PF0603

1PF0602

1PF0603

Shipping Operating Weight (lbs.)

144/136

158/150

163/153

156/146

180/170

1.  Field supplied.

kW & MBH CONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT

For a power distribution voltage that is different than the provided nominal voltage, multiply the kW and MBH data from the table by the conversion
factor in the following table.

DISTRIBUTION POWER

NOMINAL VOLTAGE

CONVERSION FACTOR

208V

240V

0.75

220V

240V

0.84

230V

240V

0.92

APPLICATION FACTORS - RATED CFM VS. ACTUAL CFM

% Of Rated Airflow (CFM)

80%

90%

100%

110%

120%

Capacity Factor

0.96

0.98

1.00

1.02

1.03

ELECTRICAL DATA - COOLING ONLY

Models

Motor FLA

1

Minimum Circuit Ampacity

MOP

2

208V

230V

208V

230V

18B/24B/30B

3.0

2.9

3.8

3.6

15

36B/36C/42C

5.0

4.5

6.3

5.6

15

48C/48D/60C/60D

7.3

7.0

9.1

8.8

15

1. FLA = Full Load Amps
2. MOP = Maximum Overcurrent Protection device; must be HACR type circuit breaker or time delay fuse. Refer to the latest edition of the 

National Electric Code or in Canada the Canadian electrical Code and local codes to determine correct wire sizing.

Summary of Contents for AVC18BX21

Page 1: ...doskeleton for structural support smooth side and locks in insulation Powder painted G30 galvanized steel case provide a coated edge that resists corrosion and rust creep MaxAlloyTM Coil Long life alu...

Page 2: ...DATA FOR MULTI SOURCE POWER SUPPLY 208 230 3 60 11 POWER WIRING LINE CONNECTIONS 11 ACCESSORIES 11 COMBUSTIBLE FLOOR BASE ACCESSORY 12 LIMITATIONS 12 TYPICAL APPLICATIONS 12 TYPICAL THERMOSTAT CONNEC...

Page 3: ...1 2 AVC60CX21 55 3 4 21 26 7 8 17 3 4 20 AVC60DX21 55 1 2 24 1 2 26 5 8 21 1 4 23 1 2 1 All dimensions are in inches 2 Actual size Conduit size in parenthesis COIL TECHNICAL DATA Models Application R...

Page 4: ...7 47 5 38 1 28 7 22 3 36C 1200 85 72 91 6 82 4 71 3 59 4 80 67 76 5 65 4 54 6 42 8 75 62 61 3 51 2 40 0 30 5 70 57 47 5 38 1 28 7 22 3 42C 1400 85 72 108 0 98 4 88 1 73 8 80 67 93 3 82 1 69 7 57 0 75...

Page 5: ...x 1 22 x 20 x 1 20 x 20 x 1 22 x 20 x 1 Permanent Type Kit 1PF0602 1PF0602 1PF0603 1PF0602 1PF0603 Shipping Operating Weight lbs 144 136 158 150 163 153 156 146 180 170 1 Field supplied kW MBH CONVERS...

Page 6: ...e disconnect breaker jumper bar 3 6HK3 3 Phase with terminal block connectors only 6HK4 3 Phase with service disconnect ELECTRIC HEAT PERFORMANCE DATA 208 230 1 60 208 230 3 60 Heater Models1 2 3 Nomi...

Page 7: ...5 45 6HK 0 1 6501006 40 49 5 53 5 50 60 6HK 1 2 6501306 52 62 7 68 1 70 70 6HK 1 2 6501506 60 71 2 77 4 80 80 6HK 1 2 6501806 72 84 4 92 0 90 100 6HK 1 2 6502006 80 92 8 101 3 100 110 36C 6HK 0 1 6500...

Page 8: ...0 7 25 25 6HK 0 1 6500506 20 30 8 32 7 35 35 6HK 0 1 6500806 32 44 0 47 3 45 50 6HK 0 1 6501006 40 52 4 56 6 60 60 6HK 1 2 6501306 52 65 6 71 3 70 80 6HK 1 2 6501506 60 74 0 80 5 80 90 6HK 1 2 6501806...

Page 9: ...45 60 50 48C 6HK16501306 52 27 9 37 6 29 5 41 5 30 40 30 45 6HK16501506 60 30 8 43 3 32 7 47 9 35 45 35 50 6HK16501806 72 48 1 39 0 51 9 43 1 50 40 60 45 6HK16502006 80 52 5 43 3 56 7 47 9 60 45 60 5...

Page 10: ...025 23 1 28 8 31 3 30 35 6HK36501525 34 6 41 2 45 1 45 50 36B 6HK36501025 23 1 31 3 33 3 35 35 6HK36501525 34 6 43 7 47 1 45 50 6HK36501825 41 6 51 3 55 5 50 60 6HK46502025 46 2 56 3 61 0 60 70 36C 6H...

Page 11: ...face For more information see the thermostat section of the Product Equipment Catalog ELECTRICAL DATA FOR MULTI SOURCE POWER SUPPLY 208 230 3 60 Air Handlers Models Heater Models1 Heater Amps 240V Min...

Page 12: ...R BASE ACCESSORY A B B A AIR HANDLER DEPTH FRONT FLOOR 1 11 PLENUM 13 FLOOR OPENING APPROX 1 2 CLEARANCE ALL AROUND FLOOR A AIR HANDLER WIDTH COMBUSTIBLE FLOOR BASE APPROX 1 2 CLEARANCE ALL AROUND C F...

Page 13: ...ol Wiring Typical A C Cooling only Applications THERMOSTAT P3 ON AIR HANDLER BOARD 1 STAGE AIR CONDITIONING R R G Y W1 W2 C G W1 W2 Y C Y Y2 Y1 O HUM C COM HUMIDISTAT A0407 001 THERMOSTAT 1 STAGE AIR...

Page 14: ...6 421 844 548 1125 731 1125 731 B C 525 341 609 335 788 512 963 626 963 626 D B 450 293 568 312 703 457 900 585 900 585 C A 475 309 675 371 750 488 1000 650 1000 650 D A 400 260 500 275 625 406 800 52...