Economizer Down Discharge/Supply Kit

 - Modulating 

integrated economizer provides simultaneous operation 
between the mechanical cooling and economizer 
operation. Independent blade design insures proper 
control and less than 1% leak rate. Includes hood and 
mesh bird screen filter integrated into the hood, dry bulb 
sensor and relief damper. Separate field accessories of 
single enthalpy and dual enthalpy are also available. A 
built-in barometric relief of 25% is provided.

Single Enthalpy Sensor

 - Sensor replaces dry bulb 

sensor standard in economizer kit. Provides improved 
economizer operation by sensing the dry bulb 
temperature from outdoors plus the enthalpy content of 
the outdoor air.

Dual Enthalpy Sensor

 - Additional sensor to single 

enthalpy sensor. Sensor senses both the return air 
temperature dry bulb and humidity in conjunction with the 
single enthalpy to determine the most economical mix. 
Single Enthalpy sensor also required.

Hail Guard Kit

 - Kit contains protective grilles made of 

expanded aluminum with full perimeter frame. Sloped 
hoods are also included to assure maximum protection.

Anti Short Cycle Timer (DNZ Units Only)

 - Automatically 

prevents the compressor from restarting for 5 minutes after 
cycled off.Not required if Thermostat 2ET07700224 and 
2ET04700224 are used. Standard in all DNX and DNY 
units.

Filter/Frame Kit (Single Phase Only)

 - Kit contains the 

necessary hardware to field install return air filters into the 
base unit. Pre-cut filter racks and appropriate cleanable 
standard size filters are shipped in one kit. The filter rack 
is suitable for either 1" or 2" filters. (1" filter is supplied) 
This kit is available for single phase horizontal or vertical 
duct application only. Standard in all 3 Phase models.

Motorized Fresh Air Damper

 - Designed for duct 

mounted side supply/return and unit mounted down 
supply/return applications. Damper capable of providing 
0% through 50% of outdoor air (field supplied). Closes on 
power loss, includes hood and screen assembly.

Rectangle To Round Adapters

 - Kit includes one supply 

and one return air rectangle to round duct adapter. 
Adapters are preformed and designed to fit over current 
duct openings on the base unit. Transition is from side 
square duct opening to 14" round duct opening.

Roof Curbs

 - NRCA approved curbs provide proper fit to 

base unit for rooftop installations. Curbs are designed to 
be assembled through hinge pins in each corner. Kit also 
provides seal strip to assure a water tight seal. 8 and 14 
inch high roof curbs are available.

Manual Outdoor Damper

 - Provides 0% through 50% 

outdoor air capability (field adjustable). Designed for duct 
mounted side supply/return applications. Includes hood 
and screen assembly.

Wall Thermostat

 - The units are designed to operate with 

24-volt electronic and electro-mechanical thermostats. All 
units can operate with single stage heat/single stage cool 
thermostats - with or without the economizer.

Low Ambient Kit

 - Kit provides necessary hardware to 

convert unit to operate in cooling cycle down to 0º F. 
Standard unit operation 45º F.

Transformer Kit

 - Kit provides necessary hardware to 

provide single phase models from factory furnished 40 VA 
transformer capability to 75 VA transformer capability. 
(Required on installations with economizer or motorized 
damper.)

Guide Specifications

General

Units shall be manufactured by York International Unitary 
Products Group in an ISO 9001 certified facility. YORK’s 
Affinity™ package units give you the flexibility and choices you 
need in today’s market. These packaged cooling/heating air 
conditioners are designed for outdoor installation. Only utility 
and duct connections are required at the point of installation. 
The single or two stage gas fired heaters have aluminized steel 
tubular heat exchangers and spark to pilot ignition. They are 
available in natural gas with field conversion to propane.

Description

Units shall be factory-assembled, single packaged, Electric 
Cooling/Gas Heating units, designed for outdoor mounted 
installation. For SEER ratings, refer to technical literature. They 
shall have built in, equal size, field convertible duct connections 
for down discharge supply/return or horizontal discharge 
supply/return. The units shall be factory wired, piped, charged 
with R-410A Refrigerant and factory tested prior to shipment. All 
unit wiring shall be both numbered and color coded. All units 
shall be manufactured in a facility certified to ISO 9001 
standards, and the cooling performance shall be rated in 
accordance with DOE and ARI test procedures. The heating 
performance shall be rated to DOE and GAMA test procedures. 
Units shall be CSA listed and classified to ANSI Z21.47/CAN/
CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 
conditions.

Unit Cabinet

Unit cabinet shall be constructed of G90 galvanized steel, with 
exterior surfaces coated with a non-chalking, powdered paint 
finish, certified at 1000 hours salt spray test per ASTM-B117 
standards. The unit top shall be a single piece “Water Shed” 
design, with drip edges and no-seam corners to provide 
optimum water integrity. Unit shall have a rigidly mounted 
condenser coil guard to provide protection from objects and 
personnel after installation. Indoor blower section shall be 
insulated with up to 3/4” thick, aluminum, foil faced insulation, 
fastened to prevent insulation from entering the air stream. 
Cabinet panels shall be “large” size, easily removable for 
servicing and maintenance, with built-in lift handles. Unit shall 
be built on a formed, “Super-Structure” design base pan, with 
embossments at critical points to add strength, rigidity and aid 
in minimizing sound. Full perimeter base rails shall be provided 
to assure reliable transit of equipment, overhead rigging, for 
truck access and proper sealing on roof curb applications. Base 

Summary of Contents for AFFINITY R-410A DNX

Page 1: ...nstallation Only utility and duct connections are required at the point of installation The single or two stage gas fired heaters have aluminized steel tubular heat exchangers and spark to pilot ignit...

Page 2: ...ube Aluminum Fin Evaporator Coil Highly Efficient Enhanced Copper Tube Aluminum Fin Condenser Coil Decorative Protective Coil Guard High Efficiency Compressor Rigidly Mounted Pilot Assembly High Grade...

Page 3: ...design allows maximum field flexibility and minimum inventory Condensate Pan A non corrosive long lasting water tight pan is positioned below the evaporator coil to collect and drain all condensate L...

Page 4: ...the unit will lock out preventing any further operation until reset or problem is corrected Exclusive Coil Design Grooved copper tubes and enhanced aluminum fin construction improves heat transfer fo...

Page 5: ...ronic and electro mechanical thermostats All units can operate with single stage heat single stage cool thermostats with or without the economizer Low Ambient Kit Kit provides necessary hardware to co...

Page 6: ...emperature protection The hermetic motor shall be suction gas cooled and have a voltage range of 10 of the unit nameplate voltage b Shall have internal isolation and sound muffling to minimize vibrati...

Page 7: ...8 49 1 8 Width 47 1 4 47 1 4 47 1 4 47 1 4 47 1 4 47 1 4 Height 33 1 2 33 1 2 33 1 2 41 1 2 41 1 2 41 1 2 OPERATING WT lbs 360 395 395 470 470 540 COMPRESSORS Type Scroll 1 spd Scroll 1 spd Scroll 1...

Page 8: ...4 Height 33 1 2 33 1 2 33 1 2 41 1 2 41 1 2 41 1 2 OPERATING WT lbs 360 395 395 470 470 540 COMPRESSORS Type Scroll 1 spd Scroll 1 spd Scroll 1 spd Scroll 1 spd Scroll 1 spd Scroll 1 spd Quantity 1 1...

Page 9: ...60 187 252 125 208 230 3 60 187 252 125 460 3 60 432 504 125 DNY DNX 208 230 1 60 187 252 115 208 230 3 60 187 252 115 460 3 60 432 504 115 042 3 5 DNZ 208 230 1 60 187 252 125 208 230 3 60 187 252 1...

Page 10: ...9 1 8 23 6 19 4 15 2 11 0 26 5 2 0 22 9 18 7 14 5 10 3 67 26 0 1 8 26 0 23 2 19 0 14 8 10 6 24 7 1 9 24 7 22 7 18 5 14 3 10 1 62 23 9 1 8 23 9 23 9 23 9 19 7 15 5 11 3 22 7 1 9 22 7 22 7 22 7 18 5 14...

Page 11: ...6 6 16 6 13 1 9 6 6 1 14 4 2 7 14 4 14 4 14 4 11 4 7 7 4 1 57 17 4 2 5 17 4 17 4 17 4 13 9 10 4 6 9 16 0 2 7 16 0 16 0 15 9 12 4 8 8 5 2 900 72 21 4 2 6 19 5 15 7 11 9 8 0 19 8 2 9 18 9 15 1 11 2 7 4...

Page 12: ...2 5 28 2 23 4 18 6 13 8 67 34 1 2 2 34 1 30 3 25 4 20 5 15 6 32 3 2 5 32 3 29 8 25 0 20 2 15 4 62 31 8 2 2 31 8 31 8 31 8 26 9 22 1 17 2 29 8 2 5 29 8 29 8 29 8 25 0 20 2 15 4 57 31 8 2 2 31 8 31 8 3...

Page 13: ...23 2 23 2 23 2 19 4 15 6 11 8 21 2 3 6 21 2 21 2 21 2 17 7 13 8 10 0 57 23 6 3 2 23 6 23 6 23 6 19 8 16 0 12 2 21 6 3 6 21 6 21 6 21 6 18 0 14 0 10 2 1125 72 27 5 3 4 24 6 20 2 15 8 11 5 25 2 3 7 24 0...

Page 14: ...3 2 34 0 28 3 22 5 16 8 67 40 6 2 8 40 6 37 6 31 7 25 9 20 0 38 4 3 2 38 4 36 0 30 2 24 5 18 7 62 36 9 2 8 36 9 36 9 36 9 31 1 25 2 19 3 35 2 3 2 35 2 35 2 35 2 29 4 23 7 17 9 57 38 0 2 7 38 0 38 0 38...

Page 15: ...3 9 28 4 28 4 28 1 23 6 19 0 14 5 26 2 4 2 26 2 26 2 26 2 21 9 17 2 12 6 57 28 8 3 9 28 8 28 8 28 8 24 2 19 7 15 1 26 6 4 2 26 6 26 6 26 6 22 3 17 5 12 9 1350 72 34 5 4 0 30 4 25 1 19 9 14 6 32 4 4 3...

Page 16: ...3 5 39 5 32 8 26 1 19 4 67 46 5 3 2 46 5 43 7 36 3 29 4 22 6 44 4 3 5 44 4 43 0 36 3 29 6 22 9 62 43 4 3 2 43 4 43 4 43 4 36 5 29 7 22 8 41 3 3 5 41 3 41 3 41 3 34 6 27 9 21 2 57 42 7 3 1 42 7 42 7 42...

Page 17: ...4 1 33 1 33 1 33 0 28 5 23 9 19 4 30 4 4 4 30 4 30 4 30 3 25 9 21 2 16 6 57 33 4 4 2 33 4 33 4 33 3 28 8 24 2 19 7 30 7 4 6 30 7 30 7 30 7 26 4 21 5 17 0 1475 72 39 0 4 4 33 9 28 2 22 5 16 7 36 0 4 8...

Page 18: ...4 2 45 6 38 0 30 3 22 7 67 55 2 3 8 55 2 49 4 41 9 34 3 26 8 51 6 4 1 51 6 48 0 40 4 32 8 25 1 62 50 7 3 7 50 7 50 7 50 7 43 2 35 7 28 2 46 9 4 2 46 9 46 9 46 9 39 3 31 6 24 0 57 49 1 3 5 49 1 49 1 49...

Page 19: ...5 0 38 0 38 0 37 6 30 9 24 1 17 4 35 8 5 4 35 8 35 8 35 6 28 9 22 0 15 2 57 39 0 4 9 39 0 39 0 37 1 30 3 23 6 16 8 37 1 5 1 37 1 37 1 35 4 28 7 21 8 15 0 1750 72 43 8 5 2 40 6 33 2 25 9 18 5 39 7 5 7...

Page 20: ...5 1 53 6 45 2 36 8 28 3 67 67 7 4 6 67 7 59 3 51 0 42 7 34 4 62 5 5 1 62 5 56 9 48 5 40 0 31 6 62 62 0 4 3 62 0 62 0 62 0 53 7 45 4 37 1 57 5 4 9 57 5 57 5 57 5 49 0 40 6 32 2 57 60 5 4 2 60 5 60 5 60...

Page 21: ...6 0 44 9 44 9 44 6 37 1 29 6 22 1 41 4 6 5 41 4 41 4 41 4 34 6 26 9 19 3 57 45 0 6 0 45 0 45 0 44 3 36 8 29 4 21 9 41 7 6 6 41 7 41 7 41 2 33 8 26 0 18 3 1925 72 53 1 6 5 46 0 37 8 29 7 21 6 48 4 7 1...

Page 22: ...atic Pressure Inch Water Gauge 0 2 0 4 0 6 0 8 1 0 SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM 024 2 0 DNZ Low 1 719 115 752 617 130 858 Low Medium 2 781 137 789 691 155 891 Medium 3 902 18...

Page 23: ...atic Pressure Inch Water Gauge 0 2 0 4 0 6 0 8 1 0 SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM 024 2 0 DNZ Low 1 719 115 752 617 130 858 Low Medium 2 781 137 789 691 155 891 Medium 3 902 18...

Page 24: ...00 0 06 0 02 0 16 1300 0 07 0 03 0 17 036 3 0 DNZ DNY DNX 700 0 01 0 00 0 04 800 0 02 0 01 0 06 900 0 03 0 01 0 08 1000 0 04 0 01 0 10 1100 0 05 0 01 0 13 1200 0 06 0 02 0 16 1300 0 07 0 03 0 17 1400...

Page 25: ...110 2220 D072 700 1350 1110 2220 DNX N065 685 1350 1080 2370 N090 685 1350 1070 1780 D090 685 1350 1070 1780 042 3 5 DNZ N065 1050 1750 1080 2370 N090 1050 1750 1070 1780 D090 1050 1750 1070 1780 048...

Page 26: ...ed at lower voltages Nominal Applied 240 208 0 75 230 0 92 480 460 0 92 600 575 0 92 Outdoor Sound Power Levels Size Tons Model Sound Rating1 dB A 1 Rated in accordance with ARI 270 standard Octave Ba...

Page 27: ...each OD Fan Motors each Supply Blower Motor MCA1 Amps 1 Minimum Circuit Ampacity Max Fuse2 Breaker3 Size Amps 2 Maximum Over Current Protection per standard UL 1995 3 Fuse or HACR circuit breaker siz...

Page 28: ...333491 YTG B 0807 Unitary Products Group 43 Typical DNX DNY DNZ024 060 Wiring Diagrams Typical DNZ024 060 Cooling Unit with Single Stage Gas Heat 208 230 1 60 volt Wiring Diagram...

Page 29: ...333491 YTG B 0807 44 Unitary Products Group Typical DNZ024 060 Cooling Unit with Two Stage Gas Heat 208 230 1 60 volt Wiring Diagram...

Page 30: ...333491 YTG B 0807 Unitary Products Group 49 Typical DNZ030 060 Cooling Unit with Single Stage Gas Heat 208 230 3 60 volt Wiring Diagram...

Page 31: ...333491 YTG B 0807 50 Unitary Products Group Typical DNZ030 060 Cooling Unit with Two Stage Gas Heat 208 230 3 60 volt Wiring Diagram...

Page 32: ...333491 YTG B 0807 Unitary Products Group 55 Typical DNZ030 060 Cooling Unit with Single Stage Gas Heat 460 3 60 volt Wiring Diagram...

Page 33: ...333491 YTG B 0807 56 Unitary Products Group Typical DNZ030 060 Cooling Unit with Two Stage Gas Heat 460 3 60 volt Wiring Diagram...

Page 34: ...5 400 20 24 5 116 84 84 117 DNX 445 440 20 24 5 127 93 93 127 030 2 5 DNZ 395 390 24 24 75 98 99 97 96 036 3 0 DNZ 400 395 24 25 100 101 98 96 DNY 445 440 20 24 25 126 91 93 129 DNX 485 480 20 24 136...

Page 35: ...ance in Top3 3 Units must be installed outdoors Over hanging structure or shrubs should not obscure condenser air discharge outlet 36 Right 12 Front 36 Left 24 Rear 0 Bottom4 4 Units may be installed...

Page 36: ...ions Front and Bottom Unit Dimensions Back and Bottom 5217 6 6833 12 287 137 211 7 21 2 92 7 211 12 287 21 16 7 5 1 137 92 7 211 12 287 2 92 7 211 12 287 92 7 211 12 287 6 5 7851 5 23 1 1 27720 5 7851...

Page 37: ...on Ground Installation Gas Model Shown 522 85 167 7 21 5 5 8 7 522 85 167 7 21 27720 8 7 6 21 5281 167 7 21 MANUAL GAS SHUT OFF VALVE TO GAS SUPPLY LINE FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REA...

Page 38: ...Gas Model Shown Unit Accessory Dimensions Roof Curb1 1 8 Roof Curb also available 0 18 6 6 87 2 9 9 6833 6 211 7 6 7 02817 21 81 7 72 32 5 6833 72 6 6833 1 21752 5 1 72 1 225 7 50267 7 5 7851 5 8 7 68...

Page 39: ...G B 0807 66 Unitary Products Group Roof Curb Cross Section 81 7 6 5 2817 5 6 1 17 675 3 168 7 21 1 522 1 0 7 5 522 1 522 1 0 7 5 168 7 21 85 5 0 0 1 29 1 6 522 22 1 5 81 7 6 6 7 1 25 85 5 0 1 8 7 6833...

Reviews: