333491-YTG-B-0807
Unitary Products Group
25
115°F
125°F
1550
77
56.4
6.3
30.2
23.6
17.0
-
-
-
51.2
6.8
28.9
22.2
15.5
-
-
-
72
51.9
6.2
39.6
33.0
26.3
19.7
-
-
47.1
6.7
38.2
31.4
24.7
18.0
-
-
67
47.4
6.1
47.4
42.3
35.7
29.1
22.4
-
43.1
6.6
43.1
40.7
34.0
27.3
20.5
-
62
44.4
5.9
44.4
44.4
42.2
35.6
29.0
22.3
40.8
6.4
40.8
40.8
39.7
33.0
26.2
19.5
57
44.5
5.9
44.5
44.5
42.0
35.3
28.7
22.1
41.1
6.4
41.1
41.1
38.8
32.1
25.3
18.6
1650
77
56.7
6.3
33.9
24.5
17.4
-
-
-
51.5
6.9
33.8
23.1
15.9
-
-
-
72
52.2
6.3
41.2
34.1
27.1
20.0
-
-
47.5
6.8
39.8
32.6
25.5
18.3
-
-
67
47.7
6.2
47.7
43.8
36.7
29.6
22.6
-
43.4
6.7
43.4
42.2
35.0
27.9
20.7
-
62
44.7
6.0
44.7
44.7
43.4
36.3
29.3
22.2
41.1
6.5
41.1
41.1
40.9
33.8
26.6
19.4
57
44.8
5.9
44.8
44.8
43.2
36.1
29.0
22.0
41.4
6.5
41.4
41.4
40.0
32.9
25.6
18.5
1750
77
57.0
6.4
37.6
25.4
17.9
-
-
-
51.9
7.0
38.7
24.0
16.4
-
-
-
72
52.5
6.3
42.8
35.3
27.8
20.3
-
-
47.8
6.9
41.4
33.8
26.2
18.6
-
-
67
47.9
6.3
47.9
45.2
37.7
30.2
22.7
-
43.7
6.8
43.7
43.7
36.1
28.5
20.8
-
62
44.9
6.0
44.9
44.9
44.6
37.1
29.6
22.1
41.4
6.5
41.4
41.4
41.4
34.6
26.9
19.3
57
45.0
6.0
45.0
45.0
44.3
36.8
29.4
21.9
41.7
6.6
41.7
41.7
41.2
33.8
26.0
18.3
1925
72
53.1
6.5
46.0
37.8
29.7
21.6
-
-
48.4
7.1
44.6
36.4
28.1
19.9
-
-
67
48.5
6.4
48.5
47.1
40.3
32.1
24.0
-
44.3
7.0
44.3
44.3
38.7
30.4
22.2
-
62
45.4
6.2
45.4
45.4
45.3
37.1
29.0
20.9
41.9
6.7
41.9
41.9
41.9
34.1
25.8
17.5
57
45.5
6.2
45.5
45.5
45.2
37.1
28.9
20.8
42.3
6.7
42.3
42.3
42.0
33.9
25.5
17.2
2100
72
53.6
6.7
49.2
40.4
31.6
22.8
-
-
49.1
7.2
47.8
38.9
30.0
21.1
-
-
67
49.0
6.6
49.0
49.0
42.8
34.1
25.3
-
44.9
7.2
44.9
44.9
41.3
32.4
23.5
-
62
45.9
6.4
45.9
45.9
45.9
37.1
28.4
19.6
42.4
6.9
42.4
42.4
42.4
33.5
24.7
15.8
57
46.0
6.4
46.0
46.0
46.0
37.3
28.5
19.7
42.8
6.9
42.8
42.8
42.8
33.9
25.0
16.1
1. These capacities are Net Capacities.
2. These ratings include the compressor, condenser fan and supply air blower motors.
DNZ060 (5.0 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Net
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Net
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65