background image

172988-YUM-A-0106

10

Unitary Products Group

FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL 

MODEL NO.

DESCRIPTION

USED WITH

1NP0680

PROPANE (LP) CONVERSION KIT WITH GAS VALVE

ALL MODELS

1CT0302

CONCENTRIC INTAKE/VENT 2”

 60, 80, 100 INPUT MBH

1CT0303

CONCENTRIC INTAKE/VENT 3”

100, 120 MBH

1NK0301

CONDENSATE NEUTRALIZER KIT

ALL MODELS

1HT0901

SIDEWALL VENT TERMINATION KIT

ALL MODELS

1CB0317

COMBUSTIBLE FLOOR BASE

17-1/2” CABINET

1CB0321

21” CABINET

1CB0324

24-1/2” CABINET

1TK0917

COIL TRANSITION KIT

17-1/2” CABINET

1TK0921

21” CABINET

1TK0924

24-1/2” CABINET

REPLACEMENT PART CONTACT INFORMATION

This is a generic parts list. To request a complete parts list, refer to the contact information below:

• Visit our website at www.source1parts.com for the following information:

1. Search for a part or browse the catalog.

2. Find a dealer or distributor.

3. Customer Service contact information.

a. Click on the “Brand Links” button

b. Click on the “Customer Service” button

• You can contact us by mail. Just send a written request to:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

Summary of Contents for Affinity PC9

Page 1: ...if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors a...

Page 2: ...furnace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal...

Page 3: ...nformation above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove burner door 5 Move gas control switch to the OFF position Do not force 6 Wait five 5...

Page 4: ...lations may have the air filter in a rack attached to the cas ing of the furnace or placed in the return air duct You can gain access to the filter by pulling on the door or unscrewing the retaining s...

Page 5: ...the gas supply at the external manual shut off valve and loosen the ground union joint 3 Remove the burner door and remove the burner box cover 4 Disconnect wires from flame sensor rollout switch and...

Page 6: ...ovides a 30 second ramp up from zero airflow to full capacity and a 30 second ramp down from full capacity back to zero airflow Whenever there is a change in airflow mode such as from low heat to high...

Page 7: ...witch on the side of the burner box It is a manual reset switch To reset push the small button in the center of the switch If it cannot be reset or if the switch trips again contact a qualified servic...

Page 8: ...Group SECTION III REPLACEMENT PARTS LIST 2 7 13 14 11 5 9 37 10 80 46 45 47 54 64 19 18 27 28 33 30 35 72 71 69 68 1 2 4 5 6 14 15 16 62 55 56 54 21 23 22 31 26 25 59 48 57 60 53 44 43 51 52 49 50 18...

Page 9: ...PLUG WINDOW CLEAR 1 5 44 COMBUSTION AIR TRANSITION 3 WAY 45 TUBING SILICONE Gray 188 ID 2 83 ft Req d 46 TUBING SILICONE Preformed 47 TUBING SILICONE Gray 188 ID 1 25 ft Req d 48 GASKET COMBUSTION BL...

Page 10: ...ET 1CB0324 24 1 2 CABINET 1TK0917 COIL TRANSITION KIT 17 1 2 CABINET 1TK0921 21 CABINET 1TK0924 24 1 2 CABINET REPLACEMENT PART CONTACT INFORMATION This is a generic parts list To request a complete p...

Page 11: ...172988 YUM A 0106 Unitary Products Group 11 SECTION IV WIRING DIAGRAM FIGURE 9 Wiring Diagram...

Page 12: ...ly to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servic...

Reviews: