19
30° 30°
To Geo 59˝ Dip Tube
w/1˝ x 3˝ Nipple
Approx. 1˝
T & P
VALVE
From Geo
1˝ x 3˝ Nipple
PRIMARY ANODE
39˝ - 80 Gallon
42˝ - 119 Gallon
3/4˝
COLD INLET
52˝ DIP TUBE
3/4˝
HOT OUTLET
w/14˝ SECONDARY ANODE
HEIGHT
Optional “To Geo”
Connection Shipped with
1-1/2˝ Pipe Plug
Taped to Bottom of Packaging
Element Location
Red Wire attached
to Thermistor or Thermostat
for Top Exit
Lower Sensor Thermistor
to be used by Hydrozone or HydroStat Controllers
Optional “From Geo” Connection
Shipped with 1-1/2˝ Pipe Plug Installed
DIAMETER
8˝
5-1/4˝
35-3/4˝
Lower Thermostat to be used
with Aurora Base Control Board
DRAIN VALVE
MODEL
NUMBER
GALLON
CAPACITY
ELEMENT
WATTAGE
(240 VOLT)
NUMBER
OF
ELEMENTS
R
VALUE
DIMENSIONS IN INCHES
APPROX.
SHIPPING
WEIGHT (lbs.)
HEIGHT
DIAMETER
GEO-STORAGE-80*
80
4500
1
16
63-1/4
24
204
GEO-STORAGE-120**
119
4500
1
16
63-1/4
28
311
Accessories and Options cont.
Geo Storage Tank Dimensions
* 040 Only
** 050 & 066 Only
NOTE:
A buffer tank is required for all hydronic heating systems using OptiHeat heat pumps. The tank should be sized to
provide a minimum of 2 gallons of storage capacity for every one thousand Btuh’s of nominal heat pump capacity. Sizing in
this manner will provide the proper amount of heat pump cycling and storage.
AFFINITY SINGLE STAGE HYDRONIC WITH OPTIHEAT INSTALLATION MANUAL