Johnson Controls Unitary Products

corners with water drip edges add to the attractive 
appearance. The cabinet panels have a non-fibrous 
insulation that will not release insulation fibers into 
conditioned area.

Top Discharge

 - The top discharge condenser fan does 

not disrupt neighboring areas or dry-out vegetation 
surrounding the unit. The warm air from the top mounted fan 
is blown up away from the structure and any landscaping. 
This allows compact location on multi-unit applications.

Condenser Coil Grille

 - All 13 SEER models and 5 ton 

14 SEER / 12 EER models utilize a decorative “Wire 
Form” coil guard to provide impact protection against 
large objects. The remaining higher SEER models utilize 
a stamped “Louvered” design which provides superior 
impact protection against smaller objects during transit 
and after installation.

Low Operating Sound Level

 - The upward air flow 

carries the normal operating noise up and away from the 
living area. The rigid top panel effectively isolates any 
motor sound. Isolator mounted compressor and the 
rippled fins of the condenser coil muffle the normal fan 
motor and compressor operating sounds. The unique 
formed base pan also aids in sound alterations with it's 
Super-Structure design. This design strategically places 
embossments in the pan for optimum strength and rigidity.

Fan System

 - All models operate over a wide range of 

design conditions with an electrically commutated fan 
motor. These units easily match all types of applications 
and provide greater on site flexibility to match comfort 
requirement. The cooling speed is factory set and can be 
field adjusted to a second speed. The heating speed is 
factory set to maintain mid point rise at the units heating 
input, but can be field adjusted. This allows maximum 
comfort conditions.

Simple Control Circuit

 - A low voltage printed circuit 

board contains a diagnostic indicator light and a low 
voltage terminal strip. An additional set of pin connectors 
is also provided to simplify the field interface of external 
controls. Mate-n-lock plug connectors are used. The 
electrical control box is not located in the compressor 
compartment. The controls are mounted on a Control-Tilt 
control panel to allow the access cover to be removed for 
trouble shooting and maintenance without affecting the 
normal system operating pressures. All wiring internal to 
the unit is color/number coded.

Protected Compressor

 - The compressor is internally 

protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high 
pressure relief valve and a temperature sensor which protect 
the compressor if undesirable operating conditions occur.

Pressure Switches 

- High pressure and low pressure/

loss of charge switches standard in all units. When 
abnormal conditions are sensed through the pressure 
switches, the unit will lock out preventing any further 
operation until reset or problem is corrected. 

Exclusive Coil Design

 - Grooved copper tubes and 

enhanced aluminum fin construction improves heat 

transfer for maximum efficiency and durability or Micro-
Channel aluminum tube, aluminum fin for long lasting 
durability and efficient operation.

Heat Exchangers

 - Are corrosion-resistant, aluminized-

steel tubular construction to provide long-life, trouble-free 
operation. The unique blow-through design also assures 
that condensate does not collect in humid areas when in 
the cooling cycle. This adds to longer heat exchanger life 
and higher long term efficiencies.

Post Purge Induced Draft Combustion

 - Exhausts 

combustion products from the heat exchanger upon 
completion of the heating cycle to prolong the heat 
exchanger life.

Self Diagnostic Fan Control Module

 - Due to this self 

diagnostic control, less on site time is required to trouble 
shoot these units.

Spark To Pilot Ignition

 - Provides faster heat delivery. 

This ignition is highly reliable, durable and eliminates 
nuisance lockouts.

Multi Port In-shot Burners

 - No field adjustment is 

required to mix the air and gas. These burners are 
constructed of high-grade corrosion-resistant, aluminized-
steel.

Low Maintenance

 - Long life, permanently lubricated 

condenser and evaporator fan motor bearings need no 
annual maintenance adding greater reliability to the unit. 
Blower assembly can be easily cleaned by the unique 
Slip- Track slide-out blower assembly.

Secured Service Access Ports

 - Protected, externally 

mounted, re-usable service access ports are provided on 
both the high and low lines for ease of evacuating and 
charging the system. No final field mounting required.

Easy Service Access

 - A large, single panel covers the 

electrical and gas controls makes servicing easy. The 
blower compartment has an additional large panel with a 
built-in handle tab. Removing this panel will allow the 
blower assembly to slide-out for easy removal for 
maintenance and ease of trouble shooting.

Replacement Parts

 - The installer requires no special 

training to replace any of the components of these units 
and does not need to maintain an inventory of unique parts.

System Integration

 - Each unit has the internal ability to 

integrate an electronic air cleaner or humidifier to work in 
conjunction with the base unit.

Field Installed Accessories

Low NOx Kit

 - Kit includes all the necessary hardware 

and instructions to field convert units to reduce emissions 
to less than 40 nanogram per Joule. California 
requirement on single phase models only.

Propane Conversion Kit

 - Kit includes burner orifices, 

gas valve conversion and installation instructions 
necessary to field convert unit from natural gas to propane.

High Altitude Conversion Kit

 (Natural Gas/Propane) - Kit 

includes all necessary labels and instructions to field alter 

Summary of Contents for AFFINITY DNQ Series

Page 1: ...nstallation Only utility and duct connections are required at the point of installation The single or two stage gas fired heaters have aluminized steel tubular heat exchangers and spark to pilot ignit...

Page 2: ...minum Fin Evaporator Coil Highly Efficient Enhanced Copper Tube Enhanced Aluminum Fin OR Micro Channel Aluminum Tube Aluminum Fin Condenser Decorative Protective Coil Guard See Features for Details Hi...

Page 3: ...gn allows maximum field flexibility and minimum inventory Condensate Pan A non corrosive long lasting water tight pan is positioned below the evaporator coil to collect and drain all condensate Less c...

Page 4: ...witches standard in all units When abnormal conditions are sensed through the pressure switches the unit will lock out preventing any further operation until reset or problem is corrected Exclusive Co...

Page 5: ...Damper Provides 0 through 50 outdoor air capability field adjustable Designed for duct mounted side supply return applications Includes hood and screen assembly Wall Thermostat The units are designed...

Page 6: ...with internal high pressure relief and over temperature protection The hermetic motor shall be suction gas cooled and have a voltage range of 10 of the unit nameplate voltage b Shall have internal iso...

Page 7: ...9 1 8 49 1 8 49 1 8 49 1 8 49 1 8 Width 47 1 4 47 1 4 47 1 4 47 1 4 47 1 4 47 1 4 Height 33 1 2 33 1 2 33 1 2 41 1 2 41 1 2 41 1 2 OPERATING WT lbs 378 398 402 460 465 480 COMPRESSORS Type Recip 1 spd...

Page 8: ...1 4 47 1 4 47 1 4 Height 33 1 2 33 1 2 33 1 2 41 1 2 41 1 2 41 1 2 OPERATING WT lbs 378 398 402 460 465 480 COMPRESSORS Type Recip 1 spd Recip 1 spd Recip 1 spd Recip 1 spd Scroll 1 spd Scroll 1 spd...

Page 9: ...252 115 208 230 3 60 187 252 115 460 3 60 432 504 115 036 3 0 DNZ 208 230 1 60 187 252 125 208 230 3 60 187 252 125 460 3 60 432 504 125 DNQ DNX 208 230 1 60 187 252 115 208 230 3 60 187 252 115 460...

Page 10: ...28 8 1 6 17 6 15 1 12 5 10 0 26 9 1 8 18 0 15 4 12 8 10 2 67 27 2 1 6 25 2 23 2 20 7 18 1 15 6 25 3 1 8 23 3 21 0 18 4 15 8 13 2 62 25 6 1 6 25 2 22 9 19 8 17 2 14 7 12 1 23 1 1 7 22 9 21 7 19 9 17 3...

Page 11: ...7 27 8 2 0 16 4 13 5 10 6 26 3 2 1 17 7 13 0 9 5 72 26 2 1 9 19 8 16 8 13 9 10 9 23 9 2 1 19 2 16 2 13 1 10 0 67 24 6 1 9 23 1 20 1 17 2 14 3 11 3 21 5 2 1 20 8 19 3 16 6 13 5 10 5 62 21 5 1 9 21 5 21...

Page 12: ...8 7 15 5 12 3 9 1 19 3 2 4 18 2 14 8 11 5 8 1 67 18 5 2 2 18 5 18 5 16 0 12 8 9 6 15 5 2 3 15 5 15 5 15 5 12 1 8 8 62 17 6 2 2 17 6 17 6 17 6 14 3 11 1 7 9 15 6 2 3 15 6 15 6 15 6 12 3 9 0 5 6 57 18 8...

Page 13: ...37 7 2 4 28 2 24 1 20 0 15 9 67 37 6 2 1 36 1 30 4 26 6 22 8 19 0 35 1 2 3 34 4 30 3 26 2 22 0 17 9 62 35 3 2 1 35 3 35 3 33 8 30 0 26 2 22 4 32 5 2 3 32 5 32 5 31 8 27 7 23 6 19 5 57 33 8 2 1 33 8 3...

Page 14: ...23 7 19 7 15 7 11 7 25 5 3 2 22 9 18 8 14 7 10 7 67 24 9 2 9 24 9 24 6 20 6 16 6 12 6 21 5 3 0 21 5 21 5 19 6 15 5 11 5 62 23 3 2 8 23 3 23 3 23 3 19 3 15 3 11 3 20 5 3 0 20 5 20 5 20 5 17 0 12 9 8 9...

Page 15: ...40 5 2 5 34 1 28 3 22 5 16 7 67 39 6 2 1 39 6 36 1 30 2 24 4 18 5 37 0 2 5 37 0 34 7 28 9 23 0 17 2 62 37 1 2 0 37 1 37 1 37 1 31 3 25 4 19 5 34 1 2 5 34 1 34 1 34 1 28 3 22 5 16 6 57 37 4 2 0 37 4 37...

Page 16: ...72 31 8 3 8 27 8 23 1 18 5 13 8 28 2 4 3 26 4 21 8 17 3 12 7 67 28 7 3 9 28 7 28 7 24 3 19 7 15 0 25 7 4 4 25 7 25 7 22 9 18 3 13 8 62 27 1 3 9 27 1 27 1 27 1 22 5 17 8 13 2 24 9 4 4 24 9 24 9 24 9 2...

Page 17: ...49 6 3 0 40 3 33 9 27 5 21 2 67 49 6 2 7 49 6 43 4 37 4 31 3 25 3 46 2 2 9 46 2 42 9 36 5 30 1 23 8 62 45 4 2 6 45 4 45 4 45 4 39 3 33 3 27 3 42 3 2 9 42 3 42 3 42 3 35 9 29 6 23 2 57 44 2 2 6 44 2 44...

Page 18: ...72 38 6 3 7 34 7 28 6 22 4 16 2 34 4 4 0 33 6 27 3 21 1 14 8 67 33 2 3 6 33 2 33 2 29 4 23 3 17 1 28 7 3 8 28 7 28 7 27 8 21 6 15 3 62 34 8 3 6 34 8 34 8 34 8 28 7 22 5 16 3 32 9 3 8 32 9 32 9 32 9 26...

Page 19: ...56 4 3 4 47 1 39 7 32 3 24 9 67 55 4 2 9 55 4 50 7 43 3 35 9 28 5 51 3 3 3 51 3 48 9 41 5 34 1 26 7 62 48 8 2 9 48 8 48 8 48 8 41 4 34 0 26 6 46 4 3 3 46 4 46 4 46 4 39 0 31 6 24 2 57 47 8 3 0 47 8 47...

Page 20: ...46 3 4 8 39 6 33 1 26 6 20 0 42 6 5 3 38 3 31 8 25 3 18 9 67 41 7 4 7 41 7 41 3 34 8 28 3 21 7 38 7 5 2 38 7 38 7 33 8 27 3 20 9 62 35 5 4 6 35 5 35 5 35 5 29 0 22 4 15 9 31 0 5 0 31 0 31 0 31 0 24 7...

Page 21: ...70 9 4 4 57 1 49 2 41 3 33 5 67 68 7 3 7 68 7 63 5 55 8 48 1 40 4 65 0 4 3 65 0 62 0 54 1 46 3 38 4 62 61 2 3 7 61 2 61 2 61 2 53 5 45 8 38 1 59 8 4 2 59 8 59 8 59 8 52 0 44 1 36 2 57 62 3 3 7 62 3 62...

Page 22: ...72 55 7 6 2 47 6 39 6 31 7 23 7 51 5 6 9 45 9 38 1 30 2 22 3 67 51 0 6 2 51 0 50 3 42 3 34 4 26 4 47 6 6 8 47 6 47 6 42 9 35 0 27 1 62 47 9 6 0 47 9 47 9 47 9 39 9 31 9 23 9 44 4 6 7 44 4 44 4 44 4 37...

Page 23: ...3 1304 395 913 1214 424 978 1114 448 1040 994 462 1098 Medium High 4 1445 515 976 1357 532 1041 1252 542 1097 1117 537 1140 High 5 1498 708 1108 1363 665 1157 1179 599 1178 042 3 5 DNZ Low 1 1114 176...

Page 24: ...3 1304 395 913 1214 424 978 1114 448 1040 994 462 1098 Medium High 4 1445 515 976 1357 532 1041 1252 542 1097 1117 537 1140 High 5 1498 708 1108 1363 665 1157 1179 599 1178 042 3 5 DNZ Low 1 1114 176...

Page 25: ...13 1200 0 06 0 02 0 16 1300 0 07 0 03 0 17 036 3 0 DNZ DNQ DNX 700 0 01 0 00 0 04 800 0 02 0 01 0 06 900 0 03 0 01 0 08 1000 0 04 0 01 0 10 1100 0 05 0 01 0 13 1200 0 06 0 02 0 16 1300 0 07 0 03 0 17...

Page 26: ...350 1110 2220 D072 700 1350 1110 2220 DNX N065 685 1350 1080 2370 N090 685 1350 1070 1780 D090 685 1350 1070 1780 042 3 5 DNZ DNQ N065 1050 1750 1080 2370 N090 1050 1750 1070 1780 D090 1050 1750 1070...

Page 27: ...applied at lower voltages Nominal Applied 240 208 0 75 230 0 92 480 460 0 92 600 575 0 92 Outdoor Sound Power Levels Size Tons Model Sound Rating1 dB A 1 Rated in accordance with ARI 270 standard Octa...

Page 28: ...14 4 20 060 5 0 208 230 1 60 26 2 150 41 2 3 7 6 42 7 60 208 230 3 60 17 9 120 28 2 3 7 6 32 3 40 460 3 60 9 6 70 15 1 3 3 8 17 1 25 DNQ024 060 Gas Heat Size Tons DNQ Volt Compressors each OD Fan Mot...

Page 29: ...333491 YTG D 0409 Johnson Controls Unitary Products 57 Typical DNX DNQ DNZ024 060 Wiring Diagrams Typical DNZ024 060 Cooling Unit with Single Stage Gas Heat 208 230 1 60 volt Wiring Diagram...

Page 30: ...333491 YTG D 0409 58 Johnson Controls Unitary Products Typical DNZ024 060 Cooling Unit with Two Stage Gas Heat 208 230 1 60 volt Wiring Diagram...

Page 31: ...333491 YTG D 0409 Johnson Controls Unitary Products 67 Typical DNZ030 060 Cooling Unit with Single Stage Gas Heat 208 230 3 60 volt Wiring Diagram...

Page 32: ...333491 YTG D 0409 68 Johnson Controls Unitary Products Typical DNZ030 060 Cooling Unit with Two Stage Gas Heat 208 230 3 60 volt Wiring Diagram...

Page 33: ...333491 YTG D 0409 Johnson Controls Unitary Products 75 Typical DNZ030 060 Cooling Unit with Single Stage Gas Heat 460 3 60 volt Wiring Diagram...

Page 34: ...333491 YTG D 0409 76 Johnson Controls Unitary Products Typical DNZ030 060 Cooling Unit with Two Stage Gas Heat 460 3 60 volt Wiring Diagram...

Page 35: ...24 5 127 93 93 127 030 2 5 DNZ 403 398 24 20 81 81 119 117 DNQ 430 425 20 24 25 122 88 90 125 036 3 0 DNZ 407 402 24 20 81 82 120 119 DNQ 435 430 20 24 25 123 89 91 127 DNX 485 480 20 24 136 98 103 14...

Page 36: ...discharge outlet 36 Right 12 Front 36 Left 24 Rear 0 Bottom4 4 Units may be installed on combustable floors made from wood or class A B or C roof covering materials 0 A B VENT AIR OUTLET HOOD BLOWER S...

Page 37: ...LTAGE CONN 7 8 DIA KNOCKOUT 4 5 8 26 3 4 CONDENSATE DRAIN 3 4 NPTF HIGH VOLTAGE CONN 1 3 32 DIA KNOCKOUT LOW VOLTAGE CONN 7 8 DIA KNOCKOUT HIGH VOLTAGE CONN 1 31 32 x 7 8 KNOCKOUT 22 1 2 43 1 2 40 1 2...

Page 38: ...d Installation Gas Model Shown ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION MANUAL GAS SHUT OFF VALVE TO GAS SUPPLY LINE FIELD SUPPLIED DISCONNECT SW...