1083294-UIM-C-0615
24
Johnson Controls Unitary Products
FIGURE 29:
Horizontal Right Configuration
If rerouting hoses - excess length should be cut of
f so that no sagging loops will collect
and hold condensate, which will cause the furnace to not operate.
When drain hose routing changes are required, be sure to cap all un-used openings.
HORIZONT
AL
- RIGHT
INDUCER ROT
A
TED
A
I
R
FL
O
W
A
I
R
FL
O
W
HORIZONT
AL
- RIGHT
INDUCER
AS RECEIVED
Move pressure switch
hose to this position.
1
Move pressure switch
hose to this position.
Change condensate
drain connection to
the 90° fitting provided.
Change condensate
drain connection to
the 90° fitting provided.
Move condensate
drain hose to this position.
Move condensate
drain hose to this position.
Move rain gutter
hose to this position.
Move rain gutter
hose to this position.
1
2
3
3
2
4
4