810753-UTG-A-0313

8

Johnson Controls Unitary Products

COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during 
the same period.
MA Modular Air Handlers use Coil Only Ratings.
— = Not Applicable.

HEATING CAPACITY - With Air Handler

UNIT

MODEL

AIR 

HANDLER

COIL

1

MODEL

HEATING

2

47 

F

17 

F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

13 SEER HP WITH AIR HANDLERS

RHP13J184S21

RFCX18BE

18.0

3.70

1.43

11.1

2.28

1.43

7.70

RFCX18BP

18.0

3.54

1.49

11.4

2.22

1.50

7.70

MX12B

FC/MC18B

18.0

3.70

1.43

11.0

2.28

1.41

8.20

MX12B

FC/MC24B

18.0

3.98

1.33

10.9

2.46

1.30

8.20

MX12B

FC/MC30B

18.0

3.98

1.33

10.9

2.46

1.30

8.20

RHP13J244S21

RFCX24BE

23.4

3.58

1.92

13.3

2.50

1.56

8.20

RFCX30BE

23.4

3.58

1.92

13.3

2.50

1.56

8.20

RFCX24BP

23.4

3.40

2.02

13.5

2.40

1.65

7.70

MX12B

FC/MC35B

23.2

3.64

1.87

13.0

2.56

1.49

8.20

MX12B

FC/MC43B

23.2

3.62

1.88

13.0

2.54

1.50

8.20

RHP13J304S21

RFCX30BE

26.6

3.40

2.29

15.5

2.42

1.88

7.70

RFCX36CE

26.8

3.56

2.21

15.3

2.50

1.79

7.70

RFCX30BP

27.6

3.30

2.45

16.2

2.32

2.05

7.70

RFCX36BP

27.8

3.36

2.42

16.2

2.32

2.05

7.70

MX12B

FC/MC35B

26.8

3.46

2.27

15.5

2.44

1.86

7.70

MX12B

FC/MC43B

27.2

3.56

2.24

15.6

2.48

1.84

7.70

MX16C

FC/MC35C

26.4

3.56

2.17

15.2

2.52

1.77

7.70

MX16C

FC/MC43C

26.4

3.56

2.17

15.2

2.50

1.78

7.70

RHP13J364S21

RFCX36CE

30.6

3.44

2.61

21.6

2.84

2.23

8.20

RFCX42DE

30.6

3.48

2.93

21.4

2.88

2.42

8.20

RFCX36BP

31.4

3.28

2.80

22.6

2.68

2.47

7.70

RFCX42CP

31.4

3.32

2.77

22.2

2.70

2.41

7.70

MX12B

FC/MC43B

30.8

3.38

2.67

21.8

2.78

2.30

7.70

MX12D

FC/MC48D

30.8

3.48

2.59

21.6

2.84

2.23

8.20

MX16C

FC/MC43C

30.2

3.44

2.57

21.0

2.84

2.17

7.70

MX16C

FC/MC48C

30.2

3.48

2.54

21.4

2.88

2.18

7.70

RHP13J424S21

RFCX48DE

39.0

3.90

3.00

21.8

2.64

2.52

8.20

RFCX48DP

40.0

3.66

3.20

22.4

2.48

2.65

7.70

MX16C

FC60C

40.0

4.08

2.87

22.0

2.66

2.42

8.20

MX20D

FC/MC60D

40.0

4.10

2.86

21.8

2.68

2.38

8.20

RHP13J484S21

RFCX48DE

45.5

3.68

3.62

26.8

2.84

2.76

8.20

RFCX60DE

44.5

3.72

3.50

26.4

2.90

2.67

8.20

RFCX48DP

46.0

3.56

3.79

27.4

2.74

2.93

7.70

RFCX60DP

45.5

3.52

3.79

27.2

2.74

2.91

7.75

MX16C

FC60C

45.0

3.80

3.47

26.2

2.96

2.59

8.20

MX20D

FC/MC60D

45.5

3.84

3.47

26.6

2.94

2.65

8.20

MX20D

FC/MC62D

45.5

3.80

3.51

26.4

2.94

2.63

8.20

RHP13J604S21

RFCX60DE

58.0

3.54

5.01

39.0

2.76

4.14

8.20

RFCX60DP

58.0

3.44

5.28

40.0

2.68

4.37

8.15

MX20D

FC/MC62D

58.0

3.58

4.95

38.5

2.76

4.09

8.20

MX20D

FC64D

58.0

3.44

5.20

40.0

2.86

4.10

8.15

1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and 

no supplemental electric heat operation.

Summary of Contents for RHP13J18 THRU 60

Page 1: ...ressure switch A factory installed liquid line filter drier further protects the com pressor against moisture and debris Environmentally Friendly Refrigerant The next genera tion refrigerant R 410A delivers environmentally friendly per formance with zero ozone depletion Durable Finish An automotive quality finish provides the ultimate protection from harmful UV rays and rust creep ensuring a long ...

Page 2: ...1075 850 850 850 850 Nominal CFM 2000 2900 3000 3800 3800 3600 3550 Coil Face Area Sq Ft 15 7 18 3 21 0 23 6 23 6 23 6 23 6 Rows Deep 1 1 1 1 1 2 2 Fins Inch 22 22 22 22 22 18 18 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 4 3 4 3 4 3 4 7 8 7 8 1 1 8 Unit Charge Lbs Oz 5 6 6 9 6 9 0 10 0 9 10 14 12 15 0 Charge Per Foot Oz 0 62 0 62 0 62 0 62 0...

Page 3: ... TXV 0 RFCX36CE 063 TXV 25 071 TXV 0 RFCX42DE 071 TXV 16 RFCX48DE 075 TXV 0 TXV 0 RFCX60DE TXV 25 TXV 0 RFCX18BP 051 TXV 0 RFCX24BP 054 TXV 0 RFCX30BP 063 TXV 0 RFCX36BP 063 TXV 25 071 TXV 6 RFCX42CP 071 TXV 16 RFCX48DP 075 TXV 0 TXV 0 RFCX60DP TXV 25 TXV 0 FC MC PC18 051 TXV 0 FC MC PC24 051 TXV 5 FC MC PC30 051 TXV 5 FC MC PC32 059 TXV 0 063 TXV 0 FC MC PC35 059 TXV 0 063 TXV 0 FC MC PC37 059 TX...

Page 4: ...0 12 00 MX12D 24 5 FC MC48D 1225 35 6 25 7 14 50 12 00 MX16C 21 0 FC MC43C 1140 35 6 25 5 14 00 12 00 MX16C 21 0 FC MC48C 1150 35 6 25 6 14 00 12 00 RHP13J424S21 RFCX48DE 24 5 1385 40 5 33 2 14 00 12 00 RFCX48DP 24 5 1320 39 5 29 6 13 00 11 00 MX16C 21 0 FC60C 1420 41 5 32 2 14 50 12 00 MX20D 24 5 FC MC60D 1470 41 5 32 2 14 50 12 00 RHP13J484S21 RFCX48DE 24 5 1635 44 0 33 2 14 00 12 00 RFCX60DE 24...

Page 5: ... MC PC60 21 0 24 5 1200 1600 1400 41 0 31 8 13 00 11 00 UC60 21 0 24 5 1200 1600 1400 40 5 31 0 13 00 11 00 RHP13J484S21 FC MC PC60 21 0 24 5 1400 1800 1600 44 0 33 4 13 00 11 00 FC MC62 24 5 1400 1800 1600 44 5 33 8 13 00 11 00 UC60 21 0 24 5 1400 1800 1600 44 0 32 8 13 00 11 00 RHP13J604S21 FC MC62 24 5 1600 2000 1800 57 5 41 0 13 25 11 35 FC64 24 5 1600 2000 1800 56 5 42 5 13 00 11 00 1 Require...

Page 6: ...0 R L CE16 21 0 FC MC PC43C 955 30 0 22 2 14 50 12 00 R L CE20 21 0 FC MC PC35C 850 29 8 21 4 14 50 12 00 R L CE20 21 0 FC MC PC43C 870 30 0 21 6 14 50 12 00 R 9 BE12 17 5 FC MC PC35B 1085 30 0 23 0 14 50 12 00 R 9 BE12 17 5 FC MC PC43B 1095 30 0 23 2 14 50 12 00 R 9 CE16 21 0 FC MC PC35C 1075 30 0 23 0 14 50 12 00 R 9 CE16 21 0 FC MC PC43C 1055 30 0 22 8 14 50 12 00 R 9 CE20 21 0 FC MC PC35C 835 ...

Page 7: ...00 R 9 CE16 21 0 FC MC62D 1550 45 0 34 2 14 50 12 00 R 9 CE16 21 0 FC PC60C 1575 44 5 33 8 14 50 12 00 R 9 CE16 21 0 UC60C 1575 44 5 33 2 14 50 12 00 R 9 CE20 21 0 FC MC62D 1595 45 0 34 2 14 50 12 00 R 9 CE20 21 0 FC PC60C 1625 44 5 34 0 14 50 12 00 R 9 CE20 21 0 UC60C 1625 44 5 33 2 14 50 12 00 R 9 DE20 24 5 FC MC PC60D 1490 45 5 33 6 14 50 12 00 R 9 DE20 24 5 FC MC62D 1610 45 0 34 2 14 50 12 00 ...

Page 8: ...5 6 2 48 1 84 7 70 MX16C FC MC35C 26 4 3 56 2 17 15 2 2 52 1 77 7 70 MX16C FC MC43C 26 4 3 56 2 17 15 2 2 50 1 78 7 70 RHP13J364S21 RFCX36CE 30 6 3 44 2 61 21 6 2 84 2 23 8 20 RFCX42DE 30 6 3 48 2 93 21 4 2 88 2 42 8 20 RFCX36BP 31 4 3 28 2 80 22 6 2 68 2 47 7 70 RFCX42CP 31 4 3 32 2 77 22 2 2 70 2 41 7 70 MX12B FC MC43B 30 8 3 38 2 67 21 8 2 78 2 30 7 70 MX12D FC MC48D 30 8 3 48 2 59 21 6 2 84 2 ...

Page 9: ...2 2 60 2 50 7 70 FC MC PC48 34 8 3 44 2 96 22 6 2 64 2 51 7 70 UC48 35 0 3 52 2 91 22 4 2 62 2 51 7 70 RHP13J424S21 FC MC PC60 40 5 3 72 3 19 23 0 2 50 2 70 7 70 UC60 40 0 3 68 3 18 22 8 2 48 2 69 7 70 RHP13J484S21 FC MC PC60 46 0 3 58 3 76 27 4 2 76 2 91 7 70 FC MC62 46 0 3 54 3 81 27 4 2 76 2 91 7 70 UC60 46 0 3 56 3 79 27 4 2 74 2 93 7 70 RHP13J604S21 FC MC62 58 0 3 44 5 24 39 5 2 66 4 35 7 80 ...

Page 10: ... 5 2 62 1 51 8 20 RHP13J304S21 R L AE12 FC MC PC32A 27 0 3 42 2 31 15 6 2 40 1 90 7 95 R L AE12 FC MC PC37A 27 8 3 64 2 24 15 9 2 50 1 86 8 20 R L BE12 FC MC PC35B 27 4 3 52 2 28 15 6 2 44 1 87 8 10 R L BE12 FC MC PC43B 27 8 3 62 2 25 15 8 2 48 1 87 8 20 R L CE16 FC MC PC35C 27 2 3 56 2 24 15 4 2 46 1 83 8 15 R L CE16 FC MC PC43C 27 2 3 64 2 19 15 4 2 52 1 79 8 20 R L CE20 FC MC PC35C 26 0 3 40 2 ...

Page 11: ...5 5 3 70 3 60 27 0 2 86 2 77 8 20 R L CE16 UC60C 45 5 3 68 3 62 26 8 2 84 2 76 8 20 R L CE20 FC MC62D 45 0 3 70 3 56 26 8 2 88 2 73 8 20 R L CE20 FC PC60C 45 5 3 72 3 58 26 8 2 88 2 73 8 20 R L CE20 UC60C 44 5 3 82 3 41 26 2 2 96 2 59 8 20 R 9 CE16 FC MC62D 45 5 3 66 3 64 26 8 2 84 2 76 8 20 R 9 CE16 FC PC60C 45 5 3 70 3 60 27 0 2 86 2 77 8 20 R 9 CE16 UC60C 45 5 3 66 3 64 26 8 2 84 2 76 8 20 R 9 ...

Page 12: ...r for each model Outdoor Thermostat S1 2TD06700124 Provides additional staging of supplemental electric heat Thermostats Compatible thermostat controls are available through accessory sourcing For optimum performance and installation refer to the UPGNET Low Voltage Wiring Diagram document to select and apply controls SOUND POWER LEVEL TYPICAL OCTAVE BAND SPECTRUM without tone adjustment Rated in a...

Page 13: ...WITH ELECTRIC HEAT DEFROST CONTROL FIELD INSTALLED JUMPER DEHUMIDIFICATION CONTROL CONNECTION Humidistat Jumper must be removed GND SCREW CONTACTOR T2 T1 L2 L1 M R L or X Y O W G T 2 E 2 R R Y Y O O W2 W C C X L G W1 BK GND LUG CIRCUIT BREAKER POWER WIRING 24V CONTROL WIRING NEC CLASS 2 JUMPER TERMINALS E AND W TO HEAT ON FIRST STAGE DURING EMERGENCY HEAT TERMINAL NOT USED ON ALL THERMOSTATS POWER...

Page 14: ... 0 17 0 18 7 16 9 16 9 15 8 17 8 19 4 S C 13 5 13 3 11 1 11 3 9 1 15 2 15 4 13 3 13 4 10 3 16 9 16 9 15 5 15 5 11 5 KW 1 60 1 60 1 60 1 60 1 60 1 70 1 70 1 70 1 70 1 70 1 80 1 80 1 70 1 80 1 80 115 T C 12 5 12 8 12 8 14 8 16 7 14 2 14 3 13 6 15 6 17 4 15 9 15 9 14 4 16 3 18 0 S C 12 5 12 6 10 5 10 7 8 6 14 2 14 3 12 7 12 8 9 8 15 9 15 9 14 4 14 9 11 0 KW 1 70 1 70 1 70 1 80 1 80 1 80 1 80 1 80 1 8...

Page 15: ... 2 10 2 10 2 20 2 20 2 20 2 20 2 30 2 30 105 T C 17 6 18 0 18 0 20 9 23 5 19 4 19 5 18 9 21 9 24 3 21 3 21 0 19 9 23 0 25 1 S C 17 6 17 2 14 5 14 7 12 0 19 4 19 3 16 7 16 9 13 2 21 3 21 0 18 8 19 1 14 4 KW 2 10 2 10 2 10 2 20 2 20 2 20 2 20 2 20 2 30 2 30 2 30 2 30 2 30 2 40 2 40 115 T C 15 8 15 5 15 4 18 8 21 5 17 6 17 5 16 2 19 7 22 4 19 5 19 5 17 0 20 6 23 3 S C 15 8 15 5 13 3 13 9 11 1 17 6 17...

Page 16: ...2 60 2 60 2 60 2 60 2 60 2 70 2 70 105 T C 21 8 22 2 21 8 25 3 28 3 23 6 23 5 22 6 26 1 29 0 25 4 24 8 23 4 26 9 29 7 S C 21 0 20 4 17 0 17 3 13 8 22 8 22 2 18 9 19 2 14 8 24 5 24 0 20 9 21 1 15 8 KW 2 50 2 50 2 50 2 60 2 70 2 70 2 70 2 60 2 70 2 80 2 80 2 80 2 70 2 80 2 90 115 T C 19 7 19 6 19 0 22 3 25 8 21 4 21 3 19 6 23 2 26 5 23 0 23 0 20 2 24 0 27 1 S C 19 0 18 9 15 8 16 1 12 7 20 6 20 6 17 ...

Page 17: ...105 T C 26 3 26 7 27 4 31 4 35 3 28 6 28 5 28 1 32 4 35 9 30 9 30 4 28 8 33 3 36 5 S C 26 3 25 5 22 3 22 4 17 8 28 6 27 9 24 3 24 5 18 9 30 9 30 4 26 3 26 5 20 0 KW 3 10 3 10 3 10 3 20 3 30 3 20 3 20 3 20 3 30 3 40 3 30 3 30 3 30 3 40 3 50 115 T C 22 8 22 6 24 1 28 5 32 2 25 6 25 5 24 5 29 2 32 8 28 4 28 4 25 0 30 0 33 5 S C 22 8 22 5 20 8 21 3 16 6 25 5 25 4 22 8 23 3 17 8 28 3 28 3 24 8 25 3 18 ...

Page 18: ... 44 1 36 6 35 4 36 0 40 7 44 7 38 3 36 8 37 0 41 4 45 3 S C 34 8 33 4 28 3 28 5 22 8 36 6 35 4 30 6 29 9 23 8 38 3 36 8 32 8 32 6 24 8 KW 3 30 3 30 3 30 3 40 3 50 3 40 3 40 3 40 3 50 3 50 3 50 3 50 3 50 3 60 3 60 105 T C 31 6 31 2 30 9 36 1 40 5 33 4 32 8 31 7 37 1 41 2 35 3 34 5 32 6 38 0 42 0 S C 31 6 31 2 26 5 26 9 21 3 33 4 32 8 28 6 29 1 22 4 35 3 34 5 30 8 31 3 23 6 KW 3 50 3 50 3 50 3 60 3 ...

Page 19: ... 37 0 36 6 28 0 KW 3 60 3 60 3 60 3 70 3 80 3 70 3 70 3 70 3 80 3 90 3 80 3 80 3 80 3 90 4 00 105 T C 37 2 37 1 36 3 40 6 45 3 38 5 37 8 36 8 41 1 45 9 39 7 38 6 37 2 41 7 46 6 S C 37 2 37 1 31 6 31 3 24 2 38 5 37 8 33 5 33 2 25 2 39 7 38 6 35 4 35 1 26 3 KW 3 90 3 90 3 90 4 00 4 10 4 00 4 00 3 90 4 00 4 20 4 10 4 10 4 00 4 10 4 20 115 T C 34 5 34 5 32 8 36 9 41 1 35 5 35 5 33 1 37 2 41 6 36 6 36 ...

Page 20: ...4 56 4 62 4 70 4 64 4 64 4 64 4 71 4 79 95 T C 51 2 51 9 52 0 57 1 62 4 52 6 52 7 52 6 57 9 63 2 54 1 53 5 53 1 58 6 64 0 S C 50 8 48 8 40 9 40 4 31 4 52 3 50 9 42 8 42 2 32 5 53 7 53 1 44 7 44 1 33 7 KW 4 89 4 90 4 90 4 97 5 05 4 98 4 98 4 98 5 06 5 14 5 07 5 07 5 06 5 14 5 23 105 T C 48 5 48 3 48 6 53 4 58 5 49 8 49 5 49 1 54 0 59 1 51 2 50 6 49 5 54 6 59 7 S C 48 1 46 6 39 4 38 8 29 9 49 5 48 4...

Page 21: ...2 70 9 6 1 9 1 45 9 9 2 0 1 44 10 2 2 1 1 44 80 9 1 1 7 1 59 9 5 1 8 1 58 9 9 1 9 1 57 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED KW VALUES ARE FOR THE SYSTEM OUTDOOR INDOOR Air Handlers Coils MBH COP KW FC MC PC18 1 05 0 94 1 13 FC MC PC24 1 06 0 98 1 08 FC MC PC30 1 06 0 98 1 08 FC MC PC35 1 00 1 00 1 00 UC24 1 05 0 98 1 08 UC30 1 05 0 98 1 08 RFCX18BE 1 03 1 01 1 02 RFCX1...

Page 22: ...2 5 2 2 1 68 13 4 2 2 1 75 14 3 2 3 1 81 10 60 12 7 2 4 1 58 11 1 2 0 1 61 9 5 1 7 1 64 70 11 1 2 0 1 59 10 7 1 9 1 64 10 3 1 8 1 69 80 9 4 1 7 1 61 10 2 1 8 1 68 11 1 1 9 1 75 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED KW VALUES ARE FOR THE SYSTEM OUTDOOR INDOOR Air Handlers Coils MBH COP KW FC MC PC32 1 00 1 00 1 00 FC MC PC35 1 00 1 00 1 00 FC MC PC37 1 01 1 01 1 00 FC MC...

Page 23: ...9 2 00 13 6 1 9 2 08 14 5 2 0 2 16 10 60 14 2 2 2 1 86 14 4 2 2 1 94 14 5 2 1 2 03 70 12 1 1 9 1 87 12 2 1 8 1 94 12 3 1 8 2 01 80 9 9 1 6 1 87 10 0 1 5 1 94 10 1 1 5 2 00 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED KW VALUES ARE FOR THE SYSTEM OUTDOOR INDOOR Air Handlers Coils MBH COP KW FC MC PC32 1 00 1 00 1 00 FC MC PC35 1 00 1 00 1 00 FC MC PC37 1 04 1 05 1 00 FC MC PC43...

Page 24: ...0 60 21 2 2 6 2 36 20 7 2 5 2 43 20 3 2 4 2 51 70 18 2 2 2 2 38 18 0 2 1 2 46 17 8 2 1 2 53 80 15 2 1 9 2 40 15 3 1 8 2 48 15 3 1 8 2 56 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED KW VALUES ARE FOR THE SYSTEM OUTDOOR INDOOR Air Handlers Coils MBH COP KW FC MC PC37 0 94 0 96 0 97 FC MC PC43 0 94 0 96 0 97 FC MC PC48 0 93 0 96 0 97 UC48 0 95 0 99 0 96 RFCX36CE 0 92 1 02 0 90 R...

Page 25: ... 31 7 3 1 2 95 30 8 3 0 3 06 80 30 3 3 0 2 96 29 4 2 8 3 06 28 5 2 6 3 16 17 60 26 6 3 0 2 64 25 8 2 8 2 71 25 0 2 6 2 79 70 22 6 2 6 2 60 21 9 2 4 2 69 21 2 2 2 2 77 80 20 3 2 2 2 67 19 7 2 1 2 77 19 1 1 9 2 87 10 60 20 9 2 5 2 47 20 1 2 3 2 57 19 3 2 1 2 66 70 18 7 2 2 2 50 18 0 2 0 2 60 17 4 1 9 2 70 80 16 4 1 9 2 52 15 9 1 8 2 63 15 4 1 7 2 73 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT A...

Page 26: ... 2 89 27 6 2 7 2 98 28 5 2 7 3 07 80 24 2 2 4 2 96 25 1 2 4 3 05 26 1 2 4 3 14 10 60 23 1 2 6 2 62 24 4 2 6 2 72 25 7 2 7 2 83 70 21 7 2 3 2 71 22 7 2 4 2 81 23 7 2 4 2 91 80 20 3 2 1 2 80 21 1 2 1 2 90 21 8 2 1 2 99 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED KW VALUES ARE FOR THE SYSTEM OUTDOOR INDOOR Air Handlers Coils MBH COP KW FC MC PC60 1 00 1 00 1 00 FC MC62 0 99 1 01...

Page 27: ...0 30 60 45 3 3 2 4 20 45 7 3 2 4 20 46 1 3 2 4 21 70 43 9 2 9 4 51 44 3 2 9 4 53 44 8 2 9 4 54 80 42 4 2 6 4 82 43 0 2 6 4 86 43 5 2 6 4 90 17 60 38 0 2 8 3 93 38 5 2 9 3 96 39 1 2 9 4 00 70 35 5 2 5 4 19 36 5 2 5 4 24 37 5 2 6 4 31 80 33 0 2 2 4 47 34 4 2 2 4 53 35 9 2 3 4 61 10 60 32 3 2 6 3 71 32 8 2 6 3 74 33 3 2 6 3 75 70 31 3 2 3 4 04 31 5 2 3 4 05 31 8 2 3 4 08 80 30 3 2 0 4 35 30 2 2 0 4 3...

Page 28: ...ect to change without notice Published in U S A 810753 UTG A 0313 Copyright 2013 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 73069 NOTES ...

Reviews: