Multipliers for determining the performance with other indoor sections.
RGF2L100CE20MP11
CF/CM64D
0.98
0.94
0.98
RGF19080CE20MP13
CF/CM64D
0.99
0.98
0.99
RGF19100CE20MP13
CF/CM64D
0.99
0.99
0.99
FURNACE MULTIPLIERS - 5 TON (Continued)
Furnaces
Coil
T.C.
S.C.
KW
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
RHP14L60B23S
AIR TEMPERATURE
ENTERING
OUTDOOR UNIT (°F)
AIR TEMPERATURE
ENTERING
INDOOR COIL (°F)
ID CFM
1600
1850
2100
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
70.3
4.89
4.21
71.2
5.14
4.06
72.2
5.39
3.91
70
68.7
4.32
4.66
69.6
4.54
4.49
70.5
4.76
4.32
80
67.1
3.85
5.11
68.0
4.06
4.91
68.8
4.26
4.71
47
60
60.5
4.46
3.97
61.3
4.66
3.86
62.2
4.85
3.75
70
59.2
3.94
4.40
60.1
4.12
4.27
61.0
4.30
4.14
80
57.9
3.52
4.82
58.8
3.68
4.68
59.8
3.85
4.54
40
60
55.1
4.19
3.85
55.8
4.34
3.76
56.5
4.50
3.67
70
54.1
3.71
4.27
54.8
3.85
4.17
55.5
3.99
4.07
80
53.1
3.32
4.69
53.9
3.45
4.58
54.6
3.57
4.47
30
60
48.0
3.79
3.71
48.2
3.88
3.64
48.4
3.97
3.57
70
46.8
3.35
4.10
46.6
3.40
4.02
46.5
3.45
3.94
80
45.6
2.98
4.49
45.1
3.01
4.39
44.5
3.04
4.29
17
60
40.2
3.33
3.54
40.8
3.39
3.52
41.3
3.46
3.50
70
39.3
2.95
3.91
40.1
3.02
3.89
40.9
3.10
3.87
80
38.5
2.64
4.27
39.5
2.72
4.26
40.5
2.79
4.25
10
60
35.9
3.06
3.44
36.3
3.10
3.43
36.74
3.15
3.42
70
35.2
2.71
3.80
35.6
2.76
3.78
36.1
2.81
3.76
80
34.4
2.42
4.16
34.9
2.48
4.13
35.4
2.53
4.10
0
60
29.2
2.57
3.33
29.5
2.61
3.32
29.9
2.64
3.31
70
28.6
2.28
3.68
29.0
2.32
3.66
29.3
2.36
3.64
80
28.0
2.04
4.03
28.4
2.08
4.00
28.8
2.13
3.97
-10
60
19.9
1.80
3.22
20.1
1.83
3.21
20.3
1.86
3.20
70
19.4
1.60
3.56
19.7
1.63
3.54
19.9
1.66
3.52
80
19.0
1.43
3.90
19.3
1.46
3.87
19.6
1.49
3.84
-20
60
13.1
1.24
3.10
13.2
1.26
3.09
13.4
1.27
3.08
70
12.8
1.10
3.42
13.0
1.12
3.40
13.1
1.14
3.38
80
12.5
0.98
3.74
12.7
1.00
3.72
12.9
1.02
3.69
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
COIL MULTIPLIERS - 5 TON
Air Handler
Coil
T.C.
S.C.
KW
RFCX60DE20MP22
—
1.00
1.00
1.00
ME20DN21
CF/CM64D
1.00
1.00
1.00
ME20DN21
XAFD60J
0.98
0.95
1.03
ME20DN21
XAHD60J
0.97
0.94
1.02
FURNACE MULTIPLIERS - 5 TON
Furnaces
Coil
T.C.
S.C.
KW
RGF1L080CE20MP12
CF/CM64D
1.00
0.96
1.04
RGF1L100CE20MP12
CF/CM64D
1.00
0.96
1.04
RGF1L120CE20MP12
CF/CM64D
1.00
0.96
1.04
RGF1L130DE20MP12
CF/CM64D
1.01
0.97
1.04
RGF2L100CE16MP11
CF/CM64D
0.99
0.95
1.04
RGF2L100CE20MP11
CF/CM64D
0.99
0.97
1.02
RGF19080CE20MP13
CF/CM64D
1.00
0.95
1.05
RGF19100CE20MP13
CF/CM64D
1.00
0.96
1.04
FURNACE MULTIPLIERS - 5 TON (Continued)
Furnaces
Coil
T.C.
S.C.
KW