5612272-UTG-H-1221
Johnson Controls Ducted Systems
55
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
RHP14L30B23S
AIR TEMPERATURE
ENTERING
OUTDOOR UNIT (°F)
AIR TEMPERATURE
ENTERING
INDOOR COIL (°F)
ID CFM
800
1000
1200
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
35.9
4.41
2.38
36.6
4.64
2.31
37.4
4.87
2.25
70
35.1
3.93
2.61
35.8
4.13
2.54
36.5
4.33
2.47
80
34.2
3.52
2.85
35.0
3.70
2.77
35.7
3.90
2.68
47
60
30.7
3.94
2.28
31.3
4.09
2.24
31.8
4.26
2.19
70
30.2
3.53
2.50
30.7
3.67
2.45
31.2
3.81
2.40
80
29.7
3.18
2.73
30.1
3.31
2.67
30.6
3.43
2.61
40
60
28.3
3.75
2.21
28.7
3.84
2.19
29.2
3.94
2.17
70
27.8
3.32
2.45
28.2
3.43
2.41
28.7
3.53
2.38
80
27.3
2.98
2.68
27.8
3.08
2.64
28.2
3.19
2.59
30
60
24.8
3.38
2.15
25.1
3.44
2.14
25.5
3.50
2.13
70
24.4
3.02
2.37
24.8
3.09
2.35
25.1
3.14
2.34
80
24.1
2.72
2.59
24.4
2.78
2.57
24.7
2.85
2.54
17
60
20.3
2.87
2.07
20.6
2.89
2.08
20.8
2.91
2.09
70
19.8
2.55
2.28
20.1
2.58
2.28
20.3
2.61
2.28
80
19.4
2.29
2.48
19.6
2.32
2.48
19.9
2.36
2.47
10
60
18.4
2.63
2.05
18.7
2.65
2.06
18.87
2.67
2.07
70
18.2
2.36
2.26
18.4
2.39
2.26
18.7
2.42
2.26
80
17.9
2.13
2.46
18.2
2.16
2.46
18.4
2.20
2.45
0
60
11.6
2.03
1.67
11.7
2.04
1.68
11.9
2.06
1.69
70
11.4
1.82
1.84
11.6
1.84
1.84
11.7
1.86
1.84
80
11.3
1.65
2.01
11.4
1.67
2.01
11.6
1.70
2.00
-10
60
8.1
1.47
1.61
8.2
1.48
1.62
8.3
1.49
1.63
70
8.0
1.32
1.78
8.1
1.33
1.78
8.2
1.35
1.78
80
7.9
1.19
1.94
8.0
1.21
1.94
8.1
1.23
1.93
-20
60
4.6
0.87
1.55
4.6
0.87
1.56
4.7
0.88
1.56
70
4.5
0.78
1.71
4.6
0.79
1.71
4.6
0.80
1.71
80
4.5
0.70
1.86
4.5
0.71
1.86
4.6
0.73
1.85
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
COIL MULTIPLIERS - 2.5 TON
Air Handler
Coil
MBH
COP
KW
—
CF/CM/CU30B
1.01
1.00
1.01
—
CF/CM/CU30C
1.01
1.00
1.01
—
CF/CM/CU30D
1.01
1.00
1.01
—
CF/CM/CU36B
1.01
1.11
0.91
—
CF/CM/CU36C
1.01
1.11
0.91
—
CF/CM/CU36D
1.01
1.11
0.91
—
CF/CM/CU42C
0.99
1.00
0.99
—
CF/CM30C
1.01
1.00
1.01
—
CF/CM36A
1.01
1.11
0.91
—
CF/CM36D
1.01
1.11
0.91
—
CF/CM42D
0.99
1.00
0.99
—
CF30BBBA1
1.01
1.00
1.01
—
CM30BBBA1
1.01
1.00
1.01
RFCX30BE10MP22
—
1.01
1.05
0.96
RFCX36BE12MP22
—
1.01
1.19
0.85
RFCX36CE12MP22
—
0.98
1.07
0.92
RFCX42CE14MP22
—
0.97
1.09
0.89
RFCX30BP10MP22
—
1.00
1.00
1.00
RFCX36BP12MP22
—
1.00
1.01
0.99
ME12BN21
CF/CM30B
1.01
1.05
0.96
ME12BN21
CF/CM36B
1.01
1.16
0.87
ME12BN21
CF30BBBA1
1.01
1.05
0.96
ME12BN21
CF42B
0.97
1.06
0.91
ME12BN21
CM30BBBA1
1.01
1.05
0.96
ME12BN21
XAF/XAUB30C
0.97
0.98
0.98
ME12BN21
XAF/XAUB36D
0.95
1.02
0.93
ME12BN21
XAHB30C
0.97
1.00
0.97
ME12BN21
XAHB36D
0.94
1.00
0.94
ME12CN21
CF/CM30C
1.01
1.04
0.98
ME12CN21
XAFC30C
0.96
0.99
0.97
ME12CN21
XAFC36D
0.95
1.03
0.92
ME12CN21
XAHC30C
0.97
1.00
0.97
ME12CN21
XAHC36D
0.94
1.01
0.93
ME14DN21
CF/CM30D
1.01
1.04
0.98
ME14DN21
CF/CM36D
1.01
1.16
0.87
ME14DN21
CF/CM42D
0.96
1.08
0.89
COIL MULTIPLIERS - 2.5 TON (Continued)
Air Handler
Coil
MBH
COP
KW