Connection
230 V AC
phaze wire
neutral wire
protective wire
L
N
INSTRUCTION FOR 'R' TYPE MOTORS: 35R AND 45R
Non-compliance with the specification might cause risk for life or health and can determine proper work of the roller shutter.
We strongly recommend to comply with the specification.
Installation of the tubular motor should be performed by specialists with 1kV or higher SEP-certified electrician's licence
(SEP - Association of Polish Electrical Engineers) or equal license.
Range
Radio receiver range is a variable value and can differ from declared values depending on conditions in which device
operates. Possible sources of changes in range are building construction, interference caused by other radio transmitters
etc.
Installation of the tubular motor should be performed by specialists with 1kV or higher SEP-certified electrician's licence
(SEP - Association of Polish Electrical Engineers) or equal license. Device is designed to operate in places shielded from
unfavourable weather conditions. Motor should be installed in accordance with all provisions of regional law and profes-
sional standards. All cables connecting power receiver with electric source should be protected from overload and
short-circuits effects with devices automatically disconnecting power. Device should be powered with a separate source
and protected only with a fast-blow fuse (never slow-blow fuse). Creating electrical system using inadequate fuse may
result in loosing rights under the provisions of warranty. When connecting device to power source with cables with
adequate cross-section should be used. Long-lasting output load capacity table should be the ground for choosing
adequate cables.
www.sukcesgroup.pl
brown wire - phaze
Adequate way to place cables,
antenna and microswitch.
230 V / 50 Hz
yellow-green wire - protective
blue wire - neutral
230 V / 50 Hz
200 m
35 m
433,92 MHz
L1
outdoor
L2
indoor
Operating
frequency
20
Roller shutter with remotely controlled motor
L2
L1