Yolanda CS20C User Manual Download Page 18

 

 

 

1

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1)This device may not cause harmful interference, and 
(2)This device must accept any interference received,including interference that may cause undesired operation. 
Attention that changes or modification not expressly approved by the party responsible for compliance could 

void the user’s authority to operate the equipment. 

Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to 

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in 
a residential installation. This product generates, uses, and can radiate radio frequency energy and,if not installed and 
used in accordance with the instructions, may cause harmful interference to radio communications. However, there 
is  no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If  this  product  does  cause  harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on,the user 
is encouraged to try to correct the interference by one or more of the following measures: 

—Reorient or relocate the receiving antenna. 
—Increase the separation between the equipment and receiver. 
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
—Consult the dealer or an experienced radio/TV technician for help. 

EMC DECLATION 

The analyzer needs special precautions regarding EMC and needs to be installed and put into service according 

to the below EMC information. 

Statement: 
The  equipment  with  following  ESSENTIAL  PERFORMANCE  is  intended  used  in  Home  healthcare 

environment and professional healthcare facility environment. 

If Essential Performance is lost or degraded due to electromagnetic disturbances,this may result in inaccurate 

measurement  and  lead  to  mislead  patients,  please  read  below  important  information  before  to  avoid  possible 
electromagnetic disturbances. 

Warning

 

Using cell phone or microwave oven, HF surgical equipment, magnetic resonance imaging or other radio radiant 

equipment near this product may cause malfunction or lead to loss of essential performance, which means that the 
measurement accuracy will be affected. 

Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in 

improper operation.If such use is necessary, this equipment and the other equipment should be observed to verify that 
they are operating normally. 

Portable  RF  communications  equipment(including  peripherals  such  as  antenna  cables  and  external 

antennas)should be used no closer than 30 cm(12 inches)to any part of the analyzer.Otherwise,degradation of the 
performance of this equipment could result. 

Use of accessories,transducers other than those specified or provided by the manufacturer of this equipment 

could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and 
result in improper operation. 

Caution: 
Security,antitheft,and radiofrequency identification(RFID)devices.Some electromagnetic anti-theft systems and 

metal detectors such as those used at entrances or exits of department stores,libraries,and other public places,and 
airport security screening devices may affect the analyzer.Additionally,RFID devices,which are often used to read 
identification badges,as well as some tag deactivation devices,such as those used at payment counters at stores and 
loan desks at libraries,may also affect the analyzer.Please do not use analyzer near these places.If you have to go 

Summary of Contents for CS20C

Page 1: ...File No XXXXXX Body Composition Analyzer User Manual Model CS20C Shenzhen Yolanda Technology Co Ltd...

Page 2: ...ble diet and exercise Bioelectrical impedance technology BIA is a detection technology that extracts the electrical impedance information of the organism to reflect the biomedical information related...

Page 3: ...oduction 3 Structure and component 4 APP Operation Instructions 8 Packing list 12 Battery Installation Replacement 12 Cleaning disinfection and Care 12 Trouble shooting 13 Standard List 13 Disposal 14...

Page 4: ...g in particular the safety precautions section Please keep this instruction manual in a convenient place for reference Description of warning and error sign or signal 1 Warning instructions and precau...

Page 5: ...bol And the Analyzer may interfere vicinity electrical equipment No modification of this equipment is allowed There is a risk of electrocution or injury Nor can precise analysis be guaranteed Any modi...

Page 6: ...re unknown 3 2 This device is contraindicated for any person who is connected to a wearable or implantable electronic device or instrument such as a pacemaker or defibrillator 4 Specifications Product...

Page 7: ...2 4G Bluetooth Frequency 2 402 2 480 GHz Bluetooth Modulation Type GFSK For Wi Fi Transmission type Wi Fi Valid Transmission Distance between Wi Fi APP and Body Composition Analyzer Up to 50 meters F...

Page 8: ...he products are mainly composed of shell glass display screen battery weight test module body fat test module Bluetooth module WiFi module and mobile terminal application software b Product basic info...

Page 9: ...product can measure body weight fat percentage BMI and other indexes After the measurement is completed the data will be transmitted to the mobile terminal application software through Bluetooth 4 0 o...

Page 10: ...change any one of these parameters and the fat percentage changes Also please do not measure under the following conditions After strenuous exercise After a bath or sauna After overeating After drinki...

Page 11: ...easuring Do not shake during measurement Keep your body relaxed APP Operation Instructions 1 Bluetooth link a Turn on the Bluetooth function and click add body fat scale as shown in Figure 1 b Wait fo...

Page 12: ...n the body composition analyzer should be turned on and complete the measurement Distribution network operation is introduced as follows Select 2 4GHzWiFi for connection as shown in Figure 1 Enter the...

Page 13: ...dy weight value is displayed on the screen and the APP will automatically search for the body composition analyzer device as shown in Figure 2 C Connect successfully wait for synchronization completio...

Page 14: ...l data A Click the history to view the user s history measurement data as shown in Figure 1 B List of historical data as shown in Figure 2 C Click Select to delete the historical data as shown in Figu...

Page 15: ...rse the device will not be able to start up but there is no damage The battery specification When the product displays LO it means that the battery power has been used up and the battery needs to be r...

Page 16: ...the equipment to return to normal operation after being transferred from the highest ambient storage temperature to an ambient temperature of 20 C Trouble shooting Returns FAIL if the user is trying...

Page 17: ...e not likely to cause any interference in nearby electronic equipment The device is suitable for use in all establishments including domestic establishments and those directly connected to the public...

Page 18: ...althcare environment and professional healthcare facility environment If Essential Performance is lost or degraded due to electromagnetic disturbances this may result in inaccurate measurement and lea...

Page 19: ...uitable for use in all establishments other than domestic and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissi...

Page 20: ...970 2450 240 0 2570 Bluetoot h WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation b 217Hz 2 0 3 28 5240 510 0 5800 WLAN 802 11 a n Pulse modulation b 217Hz 0 2 0 3 9 5500 5785 NOTE If necessary t...

Page 21: ...for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the devices can help prevent electromagnetic interference by maintaining a minimu...

Page 22: ...lai Building No 49 1 Dabao Road Dalang Area Xinan Street Baoan Shenzhen China Tel 86 755 21635022 Customer service hotline 86 400 998 2913 service time 9 00 to 21 00 of working day E mail service yola...

Reviews: