-25-
Vise etc.
■
Other precautions
●
Do not touch the oil plug except for repairing.
It can cause early oil leakage.
●
Using a tool which has been in storage for more than
6 months may cause oil leakage because of damage
to the seal part on the impulse mechanism.
When putting the tool in storage for a long period, be sure
to make the periodical maintenance, running the tool with
load every 6 months in order not to stick the seal part to
other component part.
We can offer the inspection service. Please ask us for the
service.
●
Be sure to do warm-up operation with a tool for about
10 seconds by putting a main shaft under load in cold
weather region or at the beginning of the shift in
winter season.
At the time of warm-up operation, a reverse lever
should be switched to loosening direction (L), not (R),
because the tool stops automatically if the reverse
lever is set to (R) direction.
Also note there may be a possibility of getting slip phenom-
enon (no pulsing).
※
Recommended temperature
to be used:
5℃〜40℃
CAUTION