(11) SWITCH TRQ.:
Torque at which middle speed is switched to high speed.
(12) MIN. TRQ.:
A lower limit value to make a judgment of OK/NOK.
(13) CUT TRQ.:
A torque value at which motor is automatically stopped while tightening.
(14) MAX TRQ.:
A upper limit value to make a judgment of OK/NOK.
(15) FREERUNNING ANG:
Angle between the point where a main shaft starts to rotate and the display start torque.
(16) FINAL ANG:
Angle between the display start torque and the tightening completion point.
(17) FREERUNNING TIME:
Time to display start torque after main shaft starts rotation.
(18) FINAL TIME:
Time to tightening completion from display start torque.
(19) STOP ABORT TIME:
When the rotation of main shaft is stopped for more than this time, free running angle will be
set to 0.
(20) MOTOR LOW SPEED:
Rotation speed at no load when the tool throttle lever is set to the first step.
(at forward and reverse rotation)
(21) MOTOR MID. SPEED:
Rotation speed at no load when the tool throttle lever is set to the 2nd stage. (when right rotation)
※
In case of reverse rotation, setting of mid-speed is not valid (only low and high speed is valid).
(22) MOTOR HIGH SPEED:
Rotating speed at no load when the Middle to High speed switching torque is achieved. (when
right rotation)
Rotation speed at no load when the tool throttle lever is set to the 2nd stage. (when l eft rotation)
(23) JUDGE TIME:
A set period of time to make a tightening judgment if there is no pulse during the period after the
pulsing.
(24) BOLT CO-EFFICIENT:
A coefficient number to recalculate the displayed torque of the Wireless Unit if the displayed torque
greatly differs from actual torque.
(25) AVERAGE NUM.:
The arithmetic average from the preset number of pulses to display torque.
(26) SKIP NUM.:
The number of pulses in excess of the displayed start torque, which will be ignored.